Strona 1/12
FRANCAIS
Mode d'Emploi
ENGLISH
User's Manual
DEUTSCH Bedienungsanleitung
ITALIANO Manuale di Istruzione
ESPANOL Manual de Instrucciones
CONTRÔLEURS D'ISOLEMENT
INSULATION CONTROLER
ISOLATIONSPRÜFER
CONTROLADORES DE AISLAMIENTO
CONTROLLORI DI ISOLAMENTO
C.A 6511
C.A 6513
MEGOHMMETER
11
SAFETY PRECAUTIONS
English
- Before any measurement check that there is no voltage present on the circuit to be tested.
- Use the appropriate leads supplied with the instrument.
- At rest, the needle must indicate 0 on the voltmeter scale. If not, adjust it by means of the
central (6) zero reset screw.
- When the insulation measurement is finished, leave the instrument connected for a few
seconds to allow automatic discharge of the high tension of the device tested.
- During measurement of continuity or resistance, the voltage should be measured first.
The presence of a voltage van activate protection and necessitate changing the fuses.
On the -10W +10W and 1000W ranges, the instrument is protected by an HBC fuse. On the
other ranges the instrument is statically protected on all the ranges from a voltage of
600V rms applied permanently between the terminals and from a voltage of 1000V rms
accidentally applied for less than 15 seconds between the terminals.
- Position the switch in the OFF position when the instrument is not used.
12
SUMMARY
Pages
DESCRIPTION .................................................................................................................................................................... 13
USE ............................................................................................................................................................................................. 13
Battery test .................................................................................................................................................................. 13
Insulation/voltage measurement ................................................................................................................. 13
Continuity measurement ................................................................................................................................... 14
Resistance measurement (C.A 6513 only) ......................................................................................... 14
MAINTENANCE ................................................................................................................................................................. 15
Changing the batteries/fuse ............................................................................................................................ 15
Fitting the shockproof case ............................................................................................................................. 15
Cleaning ......................................................................................................................................................................... 15
Repairs - maintenance ....................................................................................................................................... 15
SPECIFICATIONS ........................................................................................................................................................... 16
Functional specifications ................................................................................................................................... 16
Insulation ....................................................................................................................................................................... 16
Continuity ...................................................................................................................................................................... 16
Resistance (C.A 6513 only) ............................................................................................................................ 16
Voltage ............................................................................................................................................................................ 17
Reference conditions ........................................................................................................................................... 17
Climatic conditions ................................................................................................................................................. 17
Variations in the nominal working range. .............................................................................................. 18
Electrical specifications ...................................................................................................................................... 18
Power supply .............................................................................................................................................................. 18
Electrical safety ........................................................................................................................................................ 19
Mechanical specifications ................................................................................................................................. 19
STANDARDS RESPECTED .................................................................................................................................... 20
TO ORDER ........................................................................................................................................................................... 21
WARRANTY ......................................................................................................................................................................... 21


Specyfikacje produktu

Marka: Chauvin Arnoux
Kategoria: miary
Model: C.A 6513

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z Chauvin Arnoux C.A 6513, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje miary Chauvin Arnoux

Instrukcje miary

Najnowsze instrukcje dla miary

Tektronix

Tektronix TBS2204B Instrukcja

26 Września 2024
Testo

Testo 317-2 Instrukcja

24 Września 2024
Testo

Testo 883 Instrukcja

24 Września 2024
Testo

Testo 206 Instrukcja

24 Września 2024
Testo

Testo 521 Instrukcja

24 Września 2024
Testo

Testo Saveris 2 Instrukcja

24 Września 2024
Intellinet

Intellinet 780094 Instrukcja

16 Września 2024
Flir

Flir TA74 Instrukcja

14 Września 2024
Flir

Flir VT8-600 Instrukcja

14 Września 2024