Instrukcja obsługi Casambi CBU-ASD


Przeczytaj poniżej 📖 instrukcję obsługi w języku polskim dla Casambi CBU-ASD (2 stron) w kategorii inteligentny dom. Ta instrukcja była pomocna dla 5 osób i została oceniona przez 2 użytkowników na średnio 4.5 gwiazdek

Strona 1/2
ENGLISH
CBU-ASD
Bluetooth control unit for LED drivers
Warning!
Hazardous voltages. Risk of electric
shock or re. Only qualied profession-
als should make the connections. Discon-
nect the mains power supply and verify
its absence prior to installation.
L
N
www.casambi.com
230 VAC
Information in this document is subject to change.
CBU-ASD User Guide v2.0 ENG
Wiring diagram, directly powered DALI or 0-10V drivers
Dimensions
Description
CBU-ASD is a wireless control unit for LED and halogen drivers with 0-10V, 1-10V or DALI
dimming interface. CBU-ASD is available with either analog 0-10V (and 1-10V) or digital
Standalone DALI control interface.
With Standalone DALI output, CBU-ASD acts both as a controller and as a power supply
making it possible to connect directly to an LED driver with DALI interface without the need
for an external DALI power supply. This so called Standalone DALI makes it possible to
implement multi-channel lighting systems with adjustable color (RGB and RGBW) or color
temperature (CCT), while keeping the wiring and number of components at their minimum.
CBU-ASD does not comply with IEC 60929 and therefore is not designed to be connected to
an existing DALI network. The module can be used only in a closed system, i.e. as a part of
a lighting system which is not connected to an external DALI network.
CBU-ASD is controlled wirelessly with Casambi smartphone and tablet applications using
Bluetooth 4.0 protocol. The Casambi app can be downloaded free of charge from Apple App
Store and Google Play Store.
Devices form automatically a secure wireless mesh network so that a large number of x-
tures can be controlled from any point. No external gateway module is needed. CBU-ASD
can be controlled also from a standard on/o wall switches.
Range
Casambi uses mesh network technology so each
CBU-ASD acts also as a repeater. Longer ranges can
be achieved by using multiple Casambi units.
Compatible devices:
iPhone 4S or later
iPad 3 or later
iPod Touch 5th gen or later
Android 4.4 KitKat or later devices
produced after 2013 with full BT
4.0 support
50 m 1)
Up to
30 m 1)
1) Range is highly dependant on the surrounding and obstacles, such as walls and building materials.
Dimming without app
1. Turn lights on from a wall switch.
2. Quickly ick the wall switch o (max.
1 sec.) and back on. The light level
starts to increase gradually.
3. Flick the switch again at desired dim
level. The selected level is saved
automatically.
4. If the second ick is not done within
8 sec. the light intensity reaches its
maximum level.
5. Flicking the switch can also be
used to switch between predened
scenes.
ON FLICK
(<1 sec.)
FLICK
(<1 sec.)
8 sec.
from
1stick
time
Input
Voltage range: 220-240 VAC
Frequency: 50 Hz
Max. mains current: 0,6 A
Mains Output
Output relay: SSR on phase line
Voltage range: 220-240 VAC
Frequency: 50 Hz
0-10V Output
Voltage range: 0-10 VDC
Maximum number of drivers connected: 1 pc
DALI Output
Voltage range: 9-12 VDC
Maximum number of drivers connected: 1 pc
Radio transceiver
Operating frequencies: 2,4...2,483 Ghz
Maximum output power: +4 dBm
Operating conditions
Ambient temperature, ta: -20...+50°C (Iout 0 A)
-20...+40°C (Iout 0,6 A)
Max. case temperature, tc: +70 °C
Storage temperature: -25...+75 °C
Max. relative humidity: 0...80%, non-cond.
Connectors
Wire range, solid & stranded: 0,75-1,5 mm2
14-22 AWG
Wire strip length: 6-7 mm
Tightening torque: 0,4 Nm/4 Kgf.cm/2,6 Lb-In
Mechanical data
Dimensions: 56,5 x 35,8 x 22,3 mm
Weight: 48 g
Degree of protection: IP20 (indoor use only)
Protection class: Built-in Class II
Technical data
Installation
Make sure that the mains voltage is switched o when making any connections. Use 0,75-
1,5 mm2 solid or stranded conductor electrical wires. Strip the wire 6-7 mm from the end.
Insert the wires to the corresponding holes and tighten the connector screw. Make sure
to connect the input and outputs correctly. Mains input connector is marked with letters
L and N with an arrow pointing inwards, while the mains output connector is marked with
letters L and N with an arrow pointing outwards. The low voltage output is marked with +
and - symbols.
If you install CBU-ASD into a heat sensitive environment (i.e. inside a luminaire or in a ceiling
outlet box above a luminaire), make sure that the ambient temperature does not exceed the
specied maximum value.
!
Copyright Casambi Technologies Oy 2018.
Lighting control
for the Modern World
Suitable for drivers that can be switched o via control interface
DALI2)/
0-10V
230 VAC
Note 1.
DA/+
DA/-
L
N
LED driver
LED module
Wiring diagram, 1-10V drivers powered through external relay
Suitable for drivers that cannot be switched o via control interface
230 VAC
230 VAC 1-10V
L
N
+
-
L
N
LED driver
LED module
External relay
Warning!
Risk of re. Do not connect
CBU-ASD mains output directly
to LED driver mains input
!
Note 1. CBU-ASD is a built-in class II device. Use double insulated wires or an external mounting box if the
device is not mounted inside another insulated device.
Note 2. CBU-ASD and its DALI interface do not meet the requirements of IEC 60929. Connect only directly
to a DALI controllable LED driver. Not to be connected to an existing DALI network. Connect only one LED
driver (DALI or 0/1-10V driver) to one CBU-ASD.
220-240V~
max. 0.6A
Analog / D igital
dimming control
L N N L 220-240V~
max. 0.6A
Analog / D igital
dimming control
L N N L
Casambi Technologies Oy
Bertel Jungin aukio 1 E, 02600 Espoo, Finland
Disposal Instructions
In line with EU Directive 2002/96/EC for waste electrical and electronic equipment (WEEE),
this electrical product must not be disposed of as unsorted municipal waste.
Please dispose of this product by returning it to the point of sale or to your local municipal
collection point for recycling.
56,5
49,5
42,4
35,8
Mounting hole diameter:
2 x 3,5 mm
Antenna location
22,3
22
6
max. 0.6A


Specyfikacje produktu

Marka: Casambi
Kategoria: inteligentny dom
Model: CBU-ASD

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z Casambi CBU-ASD, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje inteligentny dom Casambi

Casambi

Casambi CBU-ASD Instrukcja

21 Września 2024

Instrukcje inteligentny dom

Najnowsze instrukcje dla inteligentny dom

Elro

Elro AB600S-2 Instrukcja

13 Października 2024
EZVIZ

EZVIZ DL01 Pro Instrukcja

9 Października 2024
Tenda

Tenda SP15 Instrukcja

9 Października 2024
Ikea

Ikea RODRET 005.597.95 Instrukcja

8 Października 2024
Acer

Acer Wave 7 Instrukcja

8 Października 2024
Ikea

Ikea TRETAKT 505.565.20 Instrukcja

8 Października 2024
Ikea

Ikea RODRET 505.597.93 Instrukcja

8 Października 2024
V-TAC

V-TAC VT-5132 Instrukcja

7 Października 2024