Instrukcja obsługi Carrier 42HQE012

Przeczytaj poniżej 📖 instrukcję obsługi w języku polskim dla Carrier 42HQE012 (15 stron) w kategorii klimatyzacja. Ta instrukcja była pomocna dla 5 osób i została oceniona przez 2 użytkowników na średnio 4.5 gwiazdek

Strona 1/15
Split system Hi-Wall indoor unit
ENGLISH
GB - 1
For installation instructions of this unit and the outdoor unit refer to the
installation manuals.
Contents
Page
General information .................................................................................... 2
Parts names ................................................................................................ 3
Operating temperature ................................................................................. 4
Manual operation ......................................................................................... 4
Remote controls and their functions. .......................................................... 5/6
Names and functions of indicators on remote controller ............................ 7
Remote controller ....................................................................................... 8
Use of the remote control............................................................................ 8/10
Adjusting air flow direction .......................................................................... 11/12
Optimal operation ....................................................................................... 12
Maintenance ............................................................................................... 12
Operation tips ............................................................................................. 13
Troubleshooting tips ................................................................................... 14
42HQE009. / 012.
GB - 2
General information
Read This Manual
Inside you will find many helpful hints on how to use and maintain
your air conditioner properly. Just a little preventative care on your
part can save you a great deal of time and money over the life of
your air conditioner.
You'll find many answers to common problems in the chart of
troubleshooting tips. If you review the chart of Troubleshooting
Tips first, you may not need to call for service.
CAUTION:
Contact an authorised service technician for repair or
maintenance of this unit.
Contact the installer for installation of this unit.
The air conditioner is not intended for use by young children or
invalids without supervision.
Young children should be supervised to ensure that they do not
play with the air conditioner.
If the power cord is to be replaced, replacement work shall be
performed by authorised personnel only.
Installation work must be performed in accordance with the
national wiring standards by authorised personnel only.
If the supply cord is damaged, it must be replaced by the
manufacturer or its service agent or a similarly qualified person in
order to avoid a hazard.
Safety Precautions
To prevent injury to the user or other people and property damage,
the following instructions must be followed.
Incorrect operation due to ignoring of instructions may cause harm
or damage. The seriousness is classified by the following
indications.
WARNING:
Connect with the power properly.
Otherwise, it may cause electric shock or fire due to excess heat
generation.
Do not modify power cord length or share the outlet with
other appliances.
It may cause electric shock or fire due to heat generation.
Always ensure effective earthing.
No earthing may cause electric shock.
Disconnect the power if strange sounds, smell, or smoke
comes from it.
It may cause fire and electric shock.
Keep firearms away.
It may cause fire.
Ventilate room before operating air conditioner if there is a
gas leakage from another appliance.
It may cause explosion, fire and, burns.
Do not operate or stop the unit by inserting or pulling out
the power plug.
It may cause electric shock or fire due to heat generation.
Do not operate with wet hands or in damp environment.
It may cause electric shock.
Do not allow water to run into electric parts.
It may cause failure of machine or electric shock.
Do not use the socket if it is loose or damaged.
It may cause fire and electric shock.
Do not use the power cord close to heating appliances.
It may cause fire and electric shock.
Do not damage or use an unspecified power cord.
It may cause electric shock or fire.
Do not direct airflow at room occupants only.
This could damage your health.
Always install circuit breaker and a dedicated power circuit.
No installation may cause fire and electric shock.
Do not open the unit during operation.
It may cause electric shock.
Do not use the power cord near flammable gas or
combustibles, such as gasoline, benzene, thinner, etc.
It may cause an explosion or fire.
Do not disassemble or modify unit.
It may cause failure and electric shock.
CAUTION
When the air filter is to be removed, do not touch the metal
parts of the unit.
It may cause an injury.
When the unit is to be cleaned, switch off, and turn off the
circuit breaker.
Do not clean unit when power is on as it may cause fire and
electric shock, it may cause an injury.
Stop operation and close the window in storm or hurricane.
Operation with windows opened may cause wetting of indoor
and soaking of household furniture.
• Do not place obstacles around air-inlets or inside of air-outlet.
It may cause failure of appliance or accident.
Do not use strong detergent such as wax or thinner. Use a
soft cloth for cleaning.
Appearance may be deteriorated due to change of product color
or scratching of its surface.
Do not clean the air conditioner with water.
Water may enter the unit and degrade the insulation. It may
cause an electric shock.
Do not put a pet or house plant where it will be exposed to
direct air flow.
This could injure the pet or plant.
Hold the plug by the head of the power plug when taking it
out.
Failue to do so may cause electric shock and damage.
Ensure that the installation bracket of the outdoor appliance
is not damaged due to prolonged exposure.
If bracket is damaged, there is concern of damage due to falling
of unit.
Do not place heavy object on the power cord and take care
so that the cord is not compressed.
There is danger of fire or electric shock.
Ventilate the room well when used together with a stove,
etc.
An oxygen shortage may occur.
Do not use for special purposes.
Do not use this air conditioner to preserve precision devices,
food, pets, plants, and art objects. It may cause deterioration of
quality, etc.
Turn off the main power switch when not using the unit for a
long time.
It may cause failure of product or fire.
Always insert the filters securely. Clean filter once every two
weeks.
Operation without filters may cause failure.
Do not drink water drained from air conditioner.
It contains contaminants and could make you sick.
Use caution when unpacking and installing. Sharp edges
could cause injury.
If water enters the unit, turn the unit off at the power outlet
and switch off the circuit breaker. Isolate supply by taking
the power-plug out and contact a qualified service
technician.
42HQE009. / 012.
GB - 3
E N G L I S H
Parts names
Display panel
OPERATION indicator:
The indicator flashes once every second after power is on and
illuminates when the air conditioner is in operation.
TIMER indicator:
The indicator illuminates when TIMER is set ON.
Front panel frame
Front panel
Air filter
Horizontal air flow grille
Vertical air flow louver
Room temperature sensor
Display panel
Infrared signal receiver
Remote controller
Drain hose, refrigerant connecting pipe
Connective cable
Stop valve
Outdoor unit
Indoor unit
3
10
11
12
8
7
456
9
2 1
Air inlet
Air inlet
Air outlet
Air outlet
NOTE:
The display panel on the indoor unit would look like one of
following:
TIMER
AUTO
OPERATION
PRE-DEF
ECON
Infrared signal receptor
Display panel
AUTO indicator:
This indicator flashes when the air conditioner is in AUTO operation.
ECON indicator:
This indicator illuminates while the air conditioner is in economic
operation.
Note:
All the pictures in this manual are for explanation purpose only.
They may be slightly different from the air conditioner you purchased.
The actual shape shall prevail.
The PRE.-DEF indicator will illuminates at following condition,
enough,such as at
2)A n ti-c o ld air fu n c tio n ha p p e ns w h e n th e e v a p o ra to r
is no t hig htem perature
process in heating mode.
starting
1)The air conditioner starts defrosting in heating mode.
For 42HQE009. / 012.
42HQE009. / 012.
(38YE009G/12G)
Outdoor unit
3
10
8
7
456
2 1
Air inlet
Air inlet
Air outlet
Air outlet
(38YE009QC/12QC)
MODE
FA
NSPEED
TEMP.
OK
AIRDIRECTIO N
SWING
CLO CK
CANCEL
ECO NO MIC
RUNNING
TIMER ON
TIMER
O FF
TIME ADJUST
ON
OFF
TEMP
CLOCK
SPEED
C
9
MODE
FA
NSPEED
TEMP.
OK
AIRDIRECTIO N
SWING
CLO CK
CANCEL
ECO NO MIC
RUNNING
TIMER ON
TIMER
O FF
TIME ADJUST
ON
OFF
TEMP
CLOCK
SPEED
C
11
12
Indoor unit

Specyfikacje produktu

Marka: Carrier
Kategoria: klimatyzacja
Model: 42HQE012
Kolor produktu: Srebrny
Rodzaj zasilania: PoE
Wysokość produktu: 51 mm
Szerokość produktu: 68 mm
Głębokość produktu: 42 mm
Waga produktu: 808 g
Technologia łączności: Przewodowa
Certyfikaty: CE (Class A)\nCE LVD (EN60965-1)\nFCC (Class A)\nICES-003, ICES-006\nC-Tick
Przeznaczenie: Zewnętrzna
Wielkość pamięci flash: 128 MB
Pojemność pamięci wewnętrznej: 256 MB
Obsługa PoE: Tak
Zakres temperatur (eksploatacja): -20 - 50 °C
Zakres wilgotności względnej: 0 - 90 %
Układ: Pocisk
Tryb nocny: Tak
Wi-Fi: Nie
Przewodowa sieć LAN: Tak
Pobór mocy: 6 W
Maksymalny zasięg działania: 15 m
Zakres temperatur (przechowywanie): -20 - 70 °C
Model: Kamera bezpieczeństwa IP
Technologia okablowania: 10/100Base-T(X)
Zasilanie: 24 V AC, 50/60 Hz
Maks. rozdzielczość: 1280 x 800 px
System operacyjny: Windows 7 / Vista / XP
Typ przetwornika obrazu: CMOS
Suma megapikseli: 1 MP
Zoom optyczny: - x
Min. Oświetlenie: - lx
Wbudowany HDD: Nie
Wielkość czujnika CCD: 1/4 "
Inkrypcja HTTS: Tak

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z Carrier 42HQE012, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje klimatyzacja Carrier

Instrukcje klimatyzacja

Najnowsze instrukcje dla klimatyzacja

LG

LG HS-H076QPA0 Instrukcja

15 Października 2024
Klarstein

Klarstein Vita Pure 2G Instrukcja

15 Października 2024
Gree

Gree ETAC-15HP265V20B Instrukcja

15 Października 2024
Qlima

Qlima P 126 Instrukcja

14 Października 2024
Mitsubishi

Mitsubishi MSZ-CB22VA Instrukcja

14 Października 2024
Suntec

Suntec Motion 90+ Instrukcja

14 Października 2024
Danby

Danby DTAC120B1WDB Instrukcja

14 Października 2024
Amana

Amana PTC093K35AXXX Instrukcja

14 Października 2024
Amana

Amana AMAP121AB-2 Instrukcja

14 Października 2024