MIGHTY 4 STOVE
503-0674 LEV6
MODEL No: 400, 400F
2.8kPa
USER INSTRUCTIONS
LIVE THE BRAAI LIFE
NOTE! PRODUCT MAY VARY FROM ILLUSTRATIONS
GB
1002-148/2-RSA-17-A
503-0674 LEV6 (400, 400F) Mighty 4 Stove - User Manual (SA).indd 1 2021/02/23 08:34:12
503-0674 LEV6 (400, 400F) Mighty 4 Stove - User Manual (SA).indd 2 2021/02/23 08:34:13
11
CAUTION
Provide ample ventilation. This gas appliance consumes air (oxygen). Do not use this appliance in an unventilated space to
avoid endangering your life. If still more gas appliances and/or occupants using gas are added to the space, additional ventilation
must be provided.
IMPORTANT
Read these instructions carefully so as to familiarise yourself with the appliance before ting the appliance to a gas cylinder.
Retain these instructions for future reference.
GB
1. General
This is an economic gas appliance designed for an optimal cooking experience using environment friendly LP gas.
The appliance conforms to SANS 1539:2017 and SANS 1237:2012.
Note that gures in this user manual are shown for visual purposes only and may differ to your appliance.
Please read all the instructions and warnings on the appliance before use.
It is important that all gas connections have been correctly connected to prevent any gas leaks.
Do not use a leaking, damaged or malfunctioning appliance.
This appliance requires an operating pressure of 2,8 kPa at the appliance. A suitable LPG regulator that complies with the requirements
of SANS 1237 must be installed.
Ensure that the appliance is used in a well-ventilated area.
Handle the appliance with care, do not drop it.
When using a pot, the minimum recommended pot size is 150mm and maximum pot size is 300mm.
The gas cylinder is to be used in an upright position only.
Read the instructions before using the appliance.
For outdoor use only!
2. Safety information
These instructions are for your safety and to help you avoid risk of injury and/or
damage. All warranties will become void if you do not follow these instructions.
The hose and seal on the regulator must be checked for wear or damage before every
use and before connecting to the gas cylinder.
In the event of light back (where the ame burns back and ignites at the jet)
immediately turn off the gas supply by rst closing the control valve on the gas cylinder
and then the appliance valve. After the ame is extinguished remove the regulator and
check the condition of its seal, replace the seal if in doubt. Re-light the appliance.
Should the ame persistently light back again return the product to your authorised
CADAC repair agent.
Ensure the appliance is used away from ammable materials. Minimum safe distances;
above the appliance 1.2 m, at the rear and sides 600mm (Fig. 3).
Do not use an appliance that is leaking, damaged or which does not operate properly.
Ensure that the gas cylinder is tted or changed in a well-ventilated location,
preferably outdoors, away from any sources of ignition, such as naked ames and away
from other people.
Keep gas cylinders away from heat and ame. Do not place on a stove or any other hot
surface.
Ensure that the assembled product is stable and does not rock.
Never leave the appliance unattended when lit.
If there is a leak on your appliance (smell of gas), turn off the gas supply, rstly at
the gas cylinder and then on your appliance by turning the respective knobs fully
clockwise. Take them outside immediately into a well-ventilated ame-free location
where the leak may be detected and stopped.
This appliance consumes oxygen and needs ventilation for optimum performance and
for safety of those in close proximity.
Room ventilation is important for the efcient performance of the appliance and for the
safety of the occupants in the room.
The room where this appliance is used should have a window or a door that can be
opened or partially open during use. If there is no window or door available for room
ventilation, extra ventilation must be installed for your sefety.
If you wish to check for leaks on your appliance, do it outside. Do not try to detect
leaks using a ame, use soapy water. The correct way is to smear the joints with soapy
water. If bubbles form then there is a gas leak. Immediately turn off the gas supply
rst by closing the control valve on the gas cylinder and then the appliance valve,
check that all the connections are properly tted. Re-check with soapy water. If a gas
leak persists return the product to your CADAC dealer for inspection / repair.
Do not modify the appliance. Do not use it for anything for which it has not been
designed.
During use, parts of the appliance will become hot (particularly the burner) Avoid
touching hot parts with bare hands. The use of gloves is recommended.
Keep young children away from the appliance at all times.
Do not twist or pinch the hose.
Do not move the appliance during use.
Do not use the appliance without the Potstands being in place and properly located.
Turn off the gas supply at the gas container after use.
Do not modify the appliance, any modication may be dangerous.
Fig. 1
Fig. 2
Fig. 3
503-0674 LEV6 (400, 400F) Mighty 4 Stove - User Manual (SA).indd 1 2021/02/23 08:34:19

Specyfikacje produktu

Marka: Cadac
Kategoria: Fornuis
Model: Mighty 4

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z Cadac Mighty 4, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje Fornuis Cadac

Cadac

Cadac Mighty 4 Instrukcja

23 Września 2024

Instrukcje Fornuis

Najnowsze instrukcje dla Fornuis