Strona 1/20
MODEL SPK110
Page 1
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR
INJURY TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufacturer.
If you have questions, contact the manufacturer at the address
or telephone number listed in the warranty.
2. Before servicing or cleaning unit, switch power off at service
panel and lock the service disconnecting means to prevent
power from being switched on accidentally. When the service
disconnecting means cannot be locked, securely fasten a
prominent warning device, such as a tag, to the service panel.
3. Installation work and electrical wiring must be done by a qualified
person(s) in accordance with all applicable codes and standards,
including fire-rated construction codes and standards.
4. Sufficient air is needed for proper combustion and exhausting of
gases through the flue (chimney) of fuel burning equipment to
prevent backdrafting. Follow the heating equipment manufacturer’s
guideline and safety standards such as those published by the
National Fire Protection Association (NFPA), and the American
Society for Heating, Refrigeration and Air Conditioning Engineers
(ASHRAE), and the local code authorities.
5. When cutting or drilling into wall or ceiling, do not damage
electrical wiring and other hidden utilities.
6. Ducted fans must always be vented to the outdoors.
7. Acceptable for use over a tub or shower when connected to a
GFCI (Ground Fault Circuit Interrupter) - protected branch circuit
(ceiling installation only).
8. This unit must be grounded.
CAUTION
1. For general ventilating use only. Do not use to exhaust hazardous
or explosive materials and vapors.
2. This product is designed for installation in ceilings up to a 12/12
pitch (45 degree angle). Duct connector must point up. DO NOT
MOUNT THIS PRODUCT IN A WALL.
3. To avoid motor bearing damage, noisy and/or unbalanced impellers,
or speaker damage, keep drywall spray, construction dust, etc. off
power unit and speaker diaphrams.
4. Please read specification label on product for further information
and requirements.
MODEL SPK110
SPEAKER FAN
READ AND SAVE THESE INSTRUCTIONS
To register this product visit:
www.broan.com
CLEANING & MAINTENANCE
For quiet and efficient operation, long life, and attractive appear-
ance - lower or remove grille and vacuum interior of unit with the
dusting brush attachment. Be careful vacuuming around speakers.
The motor is permanently lubricated and never needs oiling. If the
motor bearings are making excessive or unusual noises, replace
the blower assembly (includes motor and impeller).
OPERATION
Use an on/off switch to operate this ventilator. Do not use a solid-
state speed control with this Speaker Fan. See “Connect Wiring”
for details.
The Bluetooth® word mark and logos are registered trademarks owned by
Bluetooth® SIG, Inc. and any use of such marks by Broan-NuTone LLC is under
license. Other trademark and trade names are those of their respective owners.
NOTE: This equipment has been tested and found to comply with the limits for
a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in accordance with the instructions,
may cause harmful interference to radio communications. However, there is
no guarantee that interference will not occur in a particular installation. If this
equipment does cause harmful interference to radio or television reception, which
can be determined by turning the equipment off and on, the user is encouraged to
try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which the
receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
This device complies with Part 15 of the FCC Rules and RSS-210 of Canada.
Operation is subject to the following two conditions:
(1) This device may not cause interference, and (2) this device must accept any
interference received, including interference that may cause undesired operation.
FCC ID: 2ADLL-99528551 IC: 2143B-99528551
This Bluetooth ® wireless technology enabled Speaker complies with FCC radiation
exposure limits set forth for an uncontrolled environment. End users must follow
the specific operating instructions for satisfying exposure compliance. This
speaker must not be co-located or operate in conjunction with any other antenna
or transmitter.
Changes or modifications not expressly approved by the party responsible for
compliance could void the users authority to operate the equipment.
MODEL SPK110
Page 2
INSTALL SPEAKER INTO HOUSING
2. Partially install (2) #8-32 x 5/8 screws (Included in parts
bag - discard short screws and metal bracket) into threaded
holes in SPEAKER BRACKET - only so ends of screws are
flush with bottom surface of speaker bracket. Note: Installing
screws below flush will make the next couple of steps difficult.
3. Insert speaker into fan housing. Make sure SPEAKER
BRACKET BRACKET OPENINGhooks over edge of .
4. Make sure rear surface of speaker is located as close to
wall of fan housing as possible.
5. Turn #8-32 X 5/8 SCREWS (partially installed in Step
2) until they make contact with FAN PARTITION PLATE.
Alternately tighten both screws. DO NOT OVERTIGHTEN.
NOTE: Screws are designed to raise and tighten speaker
bracket against motor bracket. Screw heads may or may
not contact speaker bracket when tight.
6. Insert SPEAKER PLUG into power receptacle where
motor plug was disconnected.
7. Connect FAN MOTOR PLUG into SPEAKER WIRE
RECEPTACLE.
SPEAKER PLUG
1. Disconnect FAN MOTOR PLUG.
BRACKET
OPENING
FAN PARTITION
PLATE
#8-32 X 5/8”
SCREWS
#8-32 X 5/8”
SCREWS
FAN MOTOR PLUG
SPEAKER WIRE
RECEPTACLE
FAN MOTOR
PLUG
Video instruction for speaker installation are also available
at: www.broan.com
SPEAKER
BRACKET
SPEAKER
BRACKET
MODEL SPK110
Page 3
INSTALL HOUSING & DUCT
1. Use a pliers to
b e n d h o u s i n g
TABS out to 900.
2. Hold housing in place
so that the housing
t ab s co n t a c t th e
bottom of the joist.
The housing mounts
with four (4) screws
or nails. Screw or
nail housing to joist
through lowest holes
in each mounting
flange, then through
highest holes. NOTE:
Mounting to I-JOIST
(shown) requires use of SPACERS (included) between the
highest hole of each mounting flange and the I-joist.
SPACER
(use for mounting to I-Joist)
I-JOIST
TABS
PLAN THE INSTALLATION
Cooking
Equipment
Floor
COOKING AREA
Do not install above or
inside this area.
45
o
45
o
NOT FOR USE IN
A COOKING AREA.
ROOF CAP*
(with built-in
damper)
WALL CAP*
(with built-in
damper)
4-IN. ROUND
ELBOWS*
4-IN. ROUND
DUCT*
FAN
HOUSING
Seal gaps
around
housing.
Seal duct
joints with
tape.
Keep duct
runs short.
INSULATION
(Place around and
over fan housing.)
POWER
CABLE*
*Purchase
separately.
OR
TYPICAL INSTALLATIONS
Housing mounted to I-joists.
Use I-joist spacer block (provided).
Housing mounted to joists. Housing mounted to truss.
To mo un t ho us i ng
any whe re b e t w e e n
joists, i-joists or trusses,
use optional hanger
bar kit QTHB1 (sold
se par ate l y ) . Follow
mounting instructions
included with kit.
The ducting
from this fan
to the outside
of the building
has a strong
effect on the
air flow, noise
and energy use
of the fan. Use
the shortest,
straightest duct
routing pos-
sible for best
performance,
and avoid in-
stalling the fan with smaller ducts than recommended. Insulation around
the ducts can reduce energy loss and inhibit mold growth. Fans installed
with existing ducts may not achieve their rated airflow.


Specyfikacje produktu

Marka: Broan
Kategoria: Wentylator
Model: SPK110

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z Broan SPK110, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje Wentylator Broan

Broan

Broan A110C Instrukcja

22 Września 2024
Broan

Broan AR70LC Instrukcja

21 Września 2024
Broan

Broan E0F70 Instrukcja

21 Września 2024
Broan

Broan E070 Instrukcja

20 Września 2024
Broan

Broan E0F50 Instrukcja

20 Września 2024
Broan

Broan A80C Instrukcja

18 Września 2024
Broan

Broan E050 Instrukcja

18 Września 2024
Broan

Broan SPK110 Instrukcja

18 Września 2024
Broan

Broan QTRE110 Instrukcja

14 Września 2024

Instrukcje Wentylator

Najnowsze instrukcje dla Wentylator

Air King

Air King E130SH Instrukcja

10 Października 2024
TriStar

TriStar VE-5936 Instrukcja

10 Października 2024
Orbegozo

Orbegozo PW 1321 Instrukcja

10 Października 2024
Thermex

Thermex Silent 100 CZ Instrukcja

9 Października 2024
Imarflex

Imarflex IF-375BU Instrukcja

9 Października 2024
Imarflex

Imarflex IF-365BK Instrukcja

9 Października 2024
Kogan

Kogan KARCDCFANLA Instrukcja

9 Października 2024
Westinghouse

Westinghouse 72206 Instrukcja

9 Października 2024
Westinghouse

Westinghouse 78425 Instrukcja

9 Października 2024