EPD61 SERIES
HB0120
INTENDED FOR DOMESTIC COOKING ONLY
INSTALLER: LEAVE THIS MANUAL WITH HOMEOWNER.
HOMEOWNER: USE AND CARE INFORMATION ON PAGES 9 AND 10.
READ AND SAVE THESE INSTRUCTIONS
Broan-NuTone LLC; Hartford, Wisconsin www.broan.com 800-558-1711
Broan-NuTone Canada; Mississauga, Ontario www.broan.ca 877-896-1119
REGISTER YOUR PRODUCT ONLINE AT: www.broan.com/register
SV20571 rev. 04
! !
INSTALLATION INSTRUCTIONS
SUITABLE FOR USE IN DAMP LOCATIONS WHEN INSTALLED IN A
GFCI PROTECTED BRANCH-CIRCUIT.
I NTENDED FOR OUTDOOR COVERED PATIO OR LANAI AREA .
2
TO REDUCE THE RISK OF FIRE, ELECTRIC
SHOCK OR INJURY TO PERSONS,
OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the
manufacturer. If you have questions, contact
the manufacturer at the address or telephone
number listed in the warranty.
2. Before servicing or cleaning unit, switch
power off at service panel and lock service
disconnecting means to prevent power from
being switched on accidentally. When the
service disconnecting means cannot be locked,
securely fasten a prominent warning device,
such as a tag, to the service panel.
3. Installation work and electrical wiring must be
done by qualified personnel in accordance with
all applicable codes and standards, including
fire-rated construction codes and standards.
4. Sufficient air is needed for proper combustion
and exhausting of gases through the flue
(chimney) of fuel burning equipment to prevent
backdrafting. Follow the heating equipment
manufacturer’s guidelines and safety standards
such as those published by the National
Fire Protection Association (NFPA) and the
American Society for Heating, Refrigeration
and Air Conditioning Engineers (ASHRAE) and
the local code authorities.
5. When cutting or drilling into wall or ceiling, do not
damage electrical wiring and other hidden utilities.
6. Ducted fans must always be vented to the outdoors.
7. Do not use this unit with any additional
solid-state speed control device.
8. To reduce the risk of fire, use only metal
ductwork.
9. This unit must be grounded and protected by a
GFCI.
10. Suitable for use in damp locations only when
installed in a GFCI PROTECTED branch-circuit.
11. This unit is not designed to be used with a
charcoal grill.
12. When applicable local regulations comprise
more restrictive installation and/or certification
requirements, the aforementioned requirements
prevail on those of this document and the installer
agrees to conform to these at his own expenses.
TO REDUCE THE RISK OF A RANGE TOP
GREASE FIRE:
a) Never leave surface units unattended at high
settings. Boilovers cause smoking and greasy
spillovers that may ignite. Heat oils slowly on
low or medium settings.
b) Always turn hood ON when cooking at high heat
or when flambeing food (i.e.: Crêpes Suzette,
Cherries Jubilee, Peppercorn Beef Flambé).
c) Clean ventilating fans frequently. Grease should
not be allowed to accumulate on fan, filters or in
exhaust ducts.
d) Use proper pan size. Always use cookware
appropriate for the size of the surface element.
1. For general ventilating use only. Do not use to
exhaust hazardous or explosive materials and
vapors.
2. To avoid motor bearing damage and noisy and/
or unbalanced impellers, keep drywall spray,
construction dust, etc. off power unit.
3. Your hood motor has a thermal overload
which will automatically shut off the motor if
it becomes overheated. The motor will restart
when it cools down. If the motor continues to
shut off and restart, have the hood serviced.
4. For best capture of cooking impurities, the
bottom of the hood must be located at a minimum
distance of 36 above cooking surface.
5. Two installers are recommended because of
the large size and weight of this hood.
6. To reduce the risk of fire and to properly
exhaust air, be sure to duct air outside Do
not exhaust air into spaces within walls or
ceiling or into attics, crawl space or garage.
7. This product is equipped with a thermostat
which may start blower automatically. To reduce
the risk of injury and to prevent power from
being switched on accidentally, switch power off
at service panel and lock or tag service panel.
8. Please read specification label on product for
further information and requirements.
WARNING
CAUTION
TO REDUCE THE RISK OF INJURY TO
PERSONS IN THE EVENT OF A RANGE TOP
GREASE FIRE, OBSERVE THE FOLLOWING*:
1. SMOTHER FLAMES with a close-fitting
lid, cookie sheet or metal tray, then turn off
the burner. BE CAREFUL TO PREVENT
BURNS. IF THE FLAMES DO NOT GO OUT
IMMEDIATELY, EVACUATE AND CALL THE
FIRE DEPARTMENT.
2. NEVER PICK UP A FLAMING PAN You may
be burned.
3. DO NOT USE WATER, including wet dishcloths
or towels — This could cause a violent steam
explosion.
4. Use an extinguisher ONLY if:
A. You own a Class ABC extinguisher and you
know how to operate it.
B. The fire is small and contained in the area
where it started.
The fire department has been called.C.
D. You can fight the fire with your back to an exit.
* Based on “Kitchen Fire Safety Tips” published by
NFPA.
WARNING
! !
3
- EPD61 SERIES RANGE HOOD SYSTEM -
M 437ODEL
(HIGH CAPACITY ROOF CAP)
HL0186
M 441ODEL
(10’’ ROUND WALL CAP)
MODEL 418
(10” ROUND
ADJUSTABLE ELBOW ,
OPTIONAL)
OPTIONAL
WALL EXTENSION
AWEPD SERIES
DUAL BLOWER
(INCLUDED)
EPD61 SERIES
RANGE HOOD
10” ROUND ADAPTER
(INCLUDED)
MODEL 410
(10” ROUND DUCT
— 2 FT. SECTIONS)
OPTIONAL
DECORATIVE FLUE
AEEPD SERIES


Specyfikacje produktu

Marka: Broan
Kategoria: Okap wyciągowy
Model: EPD61

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z Broan EPD61, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje Okap wyciągowy Broan

Broan

Broan Elite RMIP45 Instrukcja

4 Października 2024
Broan

Broan Elite 619004 Instrukcja

4 Października 2024
Broan

Broan BWS1304SS Instrukcja

4 Października 2024
Broan

Broan EWS1306BLS Instrukcja

4 Października 2024
Broan

Broan BWP1304SS Instrukcja

4 Października 2024
Broan

Broan PM250 Instrukcja

4 Października 2024
Broan

Broan Elite 614804EX Instrukcja

4 Października 2024
Broan

Broan BWP1364SS Instrukcja

4 Października 2024
Broan

Broan BC4130SS Instrukcja

4 Października 2024
Broan

Broan BBN3306SSC Instrukcja

4 Października 2024

Instrukcje Okap wyciągowy

Najnowsze instrukcje dla Okap wyciągowy

Pelgrim

Pelgrim ISW990 Instrukcja

15 Października 2024
PKM

PKM 6080X Instrukcja

15 Października 2024
M-System

M-System MSPK 761 IX Instrukcja

15 Października 2024
Pelgrim

Pelgrim ISWA991RVS Instrukcja

15 Października 2024
Pelgrim

Pelgrim ISW751RVS Instrukcja

15 Października 2024
Pelgrim

Pelgrim ISW771RVS Instrukcja

15 Października 2024
Amana

Amana WVW53UC6HV Instrukcja

15 Października 2024
Haier

Haier HPH60IMB2 Instrukcja

15 Października 2024
Haier

Haier HC60BMB2 Instrukcja

15 Października 2024
Haier

Haier HPH90IMB2 Instrukcja

15 Października 2024