To mount housing anywhere between ceiling framing:
Use optional Hanger Bar Kit (sold separately from local distributors or
website). Follow mounting instructions included with kit.
1. Remove blower and all packing material
from fan housing.
2. Remove wiring
panel from fan
housing.
3. Attach damper/duct connector to
fan housing.
4. Mount housing to ceiling structure.
ROOF CAP* (with built-in damper)
WALL CAP*
(with built-in
damper)
4-IN. ROUND
ELBOWS*
FAN
HOUSING
Seal gaps
around
housing.
Seal duct joints
with tape.
INSULATION
(Place around and
over fan housing.)
POWER
CABLE *
* Purchase separately.
OR
Keep duct
runs short.
4-IN. ROUND
DUCT*
TABS
5. Connect 4-in. round duct.
ALL INSTALLATIONS
Start here.
IMPORTANT - The ducting from this fan to the outside of the
building has a strong effect on the air flow, noise and energy use
of the fan. Use the shortest, straightest duct routing possible for
best performance, and avoid installing the fan with smaller ducts
than recommended. Insulation around the ducts can reduce energy
loss and inhibit mold growth. Fans installed with existing ducts
may not achieve their rated airflow.
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY
TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufacturer.
If you have questions, contact the manufacturer at the address
or telephone number listed in the warranty.
2. Before servicing or cleaning unit, switch power off at service
panel and lock the service disconnecting means to prevent
power from being switched on accidentally. When the service
disconnecting means cannot be locked, securely fasten a
prominent warning device, such as a tag, to the service panel.
3. Installation work and electrical wiring must be done by a qualified
person(s) in accordance with all applicable codes and standards,
including fire-rated construction codes and standards.
4. Sufficient air is needed for proper combustion and exhausting
of gases through the flue (chimney) of fuel burning equipment
to prevent backdrafting. Follow the heating equipment
manufacturer’s guideline and safety standards such as those
published by the National Fire Protection Association (NFPA),
and the American Society for Heating, Refrigeration and Air
Conditioning Engineers (ASHRAE), and the local code authorities.
5. When cutting or drilling into wall or ceiling, do not damage
electrical wiring and other hidden utilities.
6. Ducted fans must always be vented to the outdoors.
7. Acceptable for use over a tub or shower when connected to a
GFCI (Ground Fault Circuit Interrupter) - protected branch circuit
(ceiling installation only).
8. This unit must be grounded.
CAUTION
1. For general ventilating use only. Do not use to exhaust hazardous
or explosive materials and vapors.
2. To avoid motor bearing damage and noisy and/or unbalanced
impellers, keep drywall spray, construction dust, etc. off power
unit.
3. Please read specification label on product for further information
and requirements.
CLEANING & MAINTENANCE
For quiet and efficient operation, long life, and attractive
appearance - lower or remove grille and vacuum interior of unit
with the dusting brush attachment.
The motor is permanently lubricated and never needs oiling. If the
motor bearings are making excessive or unusual noises, replace
the blower assembly (includes motor and impeller).
OPERATION
Use a two-function control to operate this ventilator. See “Connect
Wiring” for details.
READ AND SAVE THESE INSTRUCTIONS
Push connector
through opening from
inside of housing.
Engage tabs and
secure with screw
from parts bag.
Make sure bottom of housing will
be flush with finished ceiling.
For proper location using ½”
ceiling material: Bend out
housing tabs to fit against
bottom of structure.
Secure housing through
mounting ears with
appropriate fasteners.
If mounting housing to
I-joist, use wood blocking as
shown.
NEW CONSTRUCTION INSTALLATION
HOUSING
TABS
Cooking
Equipment
Floor
COOKING AREA
Do not install above or
inside this area.
45o45o
NOT FOR USE IN
A COOKING AREA.
SERIES FAN / LIGHT
For Retrot Installation - Skip to back page.
For Warranty Statement, Service Parts, Technical Support, or to
Register your product, please visit our website or call:
In the United States - Broan.com 800-637-1453 or NuTone.com
888-336-6151
In Canada - Broan.ca or NuTone.ca 877-896-1119
4
9. Install grille.
Install 100W max. incandescent light bulb. Plug in light. Squeeze grille
springs and insert into slots in housing. Push grille up against ceiling.
7. Connect 4-in. round duct.
Pull existing ducting through housing discharge opening and tape ducting
to duct connector. Push connector/ducting back through opening. Engage
tabs and secure with screw from parts bag.
1
2
3
TABS
*
8. Install blower.
Re-install blower removed in Step1. Secure blower with 2 screws from
parts bag and plug blower into black receptacle.
5. Connect wiring.
Bend tab to expose desired access
hole. Connect power cable to
housing with appropriate UL
approved connector. Connect black
to black, white to white, black to
red and green to green or bare wire.
Re-install wiring panel and secure
with screw from parts bag.
WIRING DIAGRAM
99045965A
SWITCH BOX
LIGHT
FAN
DUAL CONTROL
(purchase separately)
WHITE
BLACK
RED
GROUND
(bare)
WIRING PLATE
120 VAC LINE IN
RECEPTACLE
(FAN)
RECEPTACLE
(LIGHT)
6. Connect wiring.
Bend tab to expose desired access
hole. Connect power cable to
housing with appropriate UL
approved connector. Connect black
to black, white to white, black to
red and green to green or bare
wire. Re-install wiring panel and
secure with screw from parts bag.
Depending upon model - your
grille may look different. If grille spring becomes
dislodged from grille -
snap it back into place
as shown.
7. Finish ceiling - then skip to Step 8. 6. Mount fan to ceiling structure.
Mount housing to
ceiling structure with
standard drywall
or wood screws in
locations shown.
(Some models include
mounting screws.)
*Center hole optional.
2
10½-in.
9¾-in. JOIST
3. Remove old fan and prepare ceiling.
Existing fan housings are typically attached to the structure:
with screws, nails, or staples, which must be removed.
with hangers or rails which are fastened to joists and must be
removed along with housing.
A pry bar may be needed to remove the old housing.
1
4. Fold mounting
ears at against
housing.
RETROFIT INSTALLATION
Enlarge ceiling opening
(if necessary) to 9¾”
parallel to joist) by 10½
(perpendicular to joist).
(Some models have a
cut-out template on side
of carton.) Leave ductwork
and wiring in place.

Specyfikacje produktu

Marka: Broan
Kategoria: Wentylator
Model: AR70LC

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z Broan AR70LC, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje Wentylator Broan

Broan

Broan A110C Instrukcja

22 Września 2024
Broan

Broan AR70LC Instrukcja

21 Września 2024
Broan

Broan E0F70 Instrukcja

21 Września 2024
Broan

Broan E070 Instrukcja

20 Września 2024
Broan

Broan E0F50 Instrukcja

20 Września 2024

Instrukcje Wentylator

Najnowsze instrukcje dla Wentylator

Air King

Air King E130SH Instrukcja

10 Października 2024
TriStar

TriStar VE-5936 Instrukcja

10 Października 2024
Orbegozo

Orbegozo PW 1321 Instrukcja

10 Października 2024
Thermex

Thermex Silent 100 CZ Instrukcja

9 Października 2024
Imarflex

Imarflex IF-375BU Instrukcja

9 Października 2024
Imarflex

Imarflex IF-365BK Instrukcja

9 Października 2024
Kogan

Kogan KARCDCFANLA Instrukcja

9 Października 2024
Westinghouse

Westinghouse 72206 Instrukcja

9 Października 2024
Westinghouse

Westinghouse 78425 Instrukcja

9 Października 2024