MODELS 2730 & 2736 ECLIPSE
DOWNDRAFT BLOWER SYSTEM
READ AND SAVE THESE INSTRUCTIONS
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY
TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufacturer.
If you have questions, contact the manufacturer at the address
or telephone number in the warranty.
2. Before servicing or cleaning unit, switch power off at service panel
and lock the service disconnecting means to prevent power from
being switched on accidentally. When the service disconnecting
means cannot be locked, securely fasten a prominent warning
device, such as a tag, to the service panel.
3. Installation work and electrical wiring must be done by a qualified
person(s) in accordance with all applicable codes and standards,
including fire-rated construction codes and standards.
4. Sufficient air is needed for proper combustion and exhausting
of gases through the flue (chimney) of fuel burning equipment
to prevent backdrafting. Follow the heating equipment manufac-
turers guideline and safety standards such as those published
by the National Fire Protection Association (NFPA), and the
American Society for Heating, Refrigeration and Air Conditioning
Engineers (ASHRAE), and the local code authorities.
5. When cutting or drilling into wall or ceiling, do not damage electri-
cal wiring and other hidden utilities.
6. Do not use this range hood with an additional speed control
device.
7. Ducted fans must always be vented to the outdoors.
8. To reduce the risk of fire, use only metal ductwork.
9. Do not install this product with the activating switch directly behind
a burner or element. Minimum distance between the switch and
the edge of the burner should be 4 inches.
10. Loose-fitting or hanging clothing should never be worn when
operating this appliance. They may be ignited by burners/ele-
ments on cooktop.
11. Children should not be left alone or unattended in the area where
this appliance is in use.
12. This unit must be grounded.
TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:
1. Never leave surface units unattended at high settings. Boilovers
cause smoking and greasy spillovers that may ignite. Heat oils
slowly on low or medium settings.
2. Always turn hood ON when cooking at high heat or when cooking
flaming foods.
3. Clean ventilating fans frequently. Grease should not be allowed
to accumulate on fan or filter.
4. Use proper pan size. Always use cookware appropriate for the
size of the surface element.
TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT
OF A RANGE TOP GREASE FIRE, OBSERVE THE FOLLOWINGa:
1. SMOTHER FLAMES with a close-fitting lid, cookie sheet,
or metal tray, then turn off the burner. BE CAREFUL TO
PREVENT BURNS. If the flames do not go out immediately,
EVACUATE AND CALL THE FIRE DEPARTMENT.
WARNING
2. NEVER PICK UP A FLAMING PAN - You may be burned.
3. DO NOT USE WATER, including wet dishcloths or towels - a
violent steam explosion will result.
4. Use an extinguisher ONLY if:
A. You know you have a Class ABC extinguisher, and you
already know how to operate it.
B. The fire is small and contained in the area where it
started.
C. The fire department is being called.
D. You can fight the fire with your back to an exit.
a Based on “Kitchen Firesafety Tips” published by NFPA.
CAUTION
!
1. For indoor use only.
2. For general ventilating use only. Do not use to exhaust hazard-
ous or explosive materials and vapors.
3.
To avoid motor bearing damage and noisy and/or unbalanced
impellers, keep drywall spray, construction dust, etc. off power unit.
4. Clean filters and grease-laden surfaces frequently.
5. Do not repair or replace any part of this appliance unless
specifically recommended in this manual. All other servicing
should be done by a qualified technician.
6. Please read specification label on product for further informa-
tion and requirements.
INSTALLER: Save this manual for Electrical Inspector and Homeowner to use.
HOMEOWNER: Use and Care Information on Page 5.
!
INTENDED FOR DOMESTIC COOKING ONLY
!
Register your product online at: www.broan.com/register
1
GROUNDING INSTRUCTIONS
WARNING - This appliance must be grounded. In the event of an
electrical short-circuit, grounding reduces the risk of the electric
shock by providing an escape wire for the electric current. This
appliance is equipped with a cord having a grounding wire with
a grounding plug. The plug must be plugged into an outlet that
is properly installed and grounded.
WARNING - Improper grounding can result in a risk of electric shock.
Consult a qualified electrician if the grounding instructions are
not completely understood, or if doubt exists as to whether the
appliance is properly grounded.
Do not use an extension cord. If the power supply cord is too short,
have a qualified electrician install an outlet near the appliance.
RIGHT
DISCHARGE
DOWN
DISCHARGE
(as shipped)
LEFT
DISCHARGE
EQUALS 6 FT. OF
STRAIGHT DUCT
6" ROUND
ELBOW
3-1/4" X 10"
TO 6" RD.
TRANSITION
3-1/4" X 10"
90O ELBOW
EQUALS 8
FT. OF
STRAIGHT DUCT
EQUALS 2
FT. OF
STRAIGHT DUCT
2
PLAN THE WIRINg
1. The downdraft blower system draws 4 AMPS and requires a
120 VAC, 60 Hz circuit.
2. The unit has a 2 ft. long power cord with a 3-pronged plug.
Plan to provide a grounded outlet in a location which will allow
the unit’s power cord to reach. (Note: If the Model 2730 is be-
ing installed in a 30" wide cabinet or the Model 2736 is being
installed in a 36" wide cabinet, the outlet cannot be located
on the back wall of cabinet.) Outlet may also be wall-mounted,
with access hole in cabinet.
SPECIFICATIONS
VOLTS AMPS CFM DUCT
4.0 500 3-1/4 X 10120
TAKE MEASUREMENTS
1. Refer to the cooktop installation instructions for dimensions of
cooktop, countertop cut-out, and cabinet requirements. The
Model 2730 will fit in most 30" wide cabinets and the Model
2736 will fit in most 36" wide cabinets. However, it is recom-
mended that oversized cabinets be used for easier installation.
2. Cooktop depth can vary greatly from one to another. This may
cause the fit of these two appliances to be rather tight.
Pay special attention to the areas of potential interference high-
lighted above. A countertop with (A) a raised lip and/or (B) a
backsplash may not allow enough flat countertop for a proper
installation. Note that 2" of flat countertop is required behind
cooktop and that 1-3/4" is necessary between the back edge of
the cooktop and the inside of cabinet back.
PLAN THE DUCTWORK
1. This downdraft blower system is designed for use with 3-1/4" x
10" ductwork (can be transitioned to 6" round). Three different
discharge directions are available with side-to-side adjustment
for accurate alignment of ductwork.
2. For best performance: Choose the ducting option which al-
lows the shortest length of ductwork and a minimum number
of elbows and transitions. Check location of floor joists, wall
studs, electrical wiring or plumbing for possible interference.
NOTE: The unit is shipped with the 3-1/4" x 10" discharge
facing DOWN. See “CHANGING BLOWER DIRECTION” on
page 3, if necessary.
3. The system will operate most efficiently when the ductwork
does not exceed 40 feet of equivalent duct. The chart, above,
shows equivalent feet of elbows and transitions. The number
of feet of straight duct plus the equivalent feet of transitions
and/or elbows to be used should equal 40 feet or less.
NOTE: The equivalent feet of various roof and wall caps has
been taken into consideration. Do not include them in this
calculation.
AIR
VENT
COUNTER
TOP
BLOWER
BOX
CHIMNEY TOP
3-1/4" X 10"
DUCT CONNECTOR
COOK TOP
GEAR
MOTOR
COVER
TYPICAL INSTALLATION
120 VAC
GROUNDED
OUTLET
PLANNINg
This downdraft blower system is
designed to be used to exhaust
airborne contaminants when
cooking with a variety of gas
or electric cooktops. It can be
mounted in island, peninsula, or
conventional wall locations.
This unit can be easily installed
following these basic steps:
Cut out the countertop
opening.
Mount the unit in the cabinet.
Connect the ductwork and
electrical.
Install the cooktop.
Note: The high level of air flow of this appliance may affect the
gas flame on some types of gas cooktops. This is NORMAL and
will cause no harm, but can be corrected by lowering the speed
of the blower.
LEVELING BRACKET -
FLANGE FACING IN
LEVELING BRACKET -
FLANGE FACING OUT
MOUNTING SCREWS
COVER PLATE
CLAMP
CHANNEL
NUT
BLOWER
MOTOR
PLUG
SHEET
METAL
SCREW
CLAMP
CHANNEL
NUTS
SHEET
METAL
SCREW
BOTTOM
FLANGE
BLOWER
3
PREPARATION
CHANgINg BLOWER DISCHARgE (Optional)
The blower is shipped with its discharge facing DOWN. Follow
these steps ONLY if:
the position of the blower discharge needs to be moved so duct-
work does not interfere with floor joists, plumbing or wiring below.
it is necessary to rotate the blower discharge to the RIGHT or LEFT.
Place the unit on its back on a table or work surface.
DOWN DISCHARgE - MOVINg BLOWER LEFT OR RIgHT
1. Loosen the 4 nuts and 2 clamp channels.
2. Slide blower to desired position.
3. Use supplied cover plate to close open space (if any).
4. Tighten wing nuts to secure top of blower and use sheet metal
screws through bottom flange to secure bottom of blower.
LEFT OR RIgHT DISCHARgE
1. Remove the 4 nuts and 2 clamp channels.
2. Carefully lift blower and disconnect motor plug if necessary.
Reposition blower and RECONNECT MOTOR PLUG.
3. Use supplied cover plate to close open space (if any).
4. Replace clamp channels and use nuts to secure the blower
in its new position.
5. Use sheet metal screws through bottom flange to secure bot-
tom of blower.
CUT COUNTERTOP OPENINg
1. Lay out and cut the cooktop cut-out far enough FORWARD
so downdraft will fit behind it.
2. Set cooktop in place and slide it as far forward as possible.
Center and square it with edges of countertop.
3. Place the plastic template against the back flange of the cook-
top and center it. Trace around template to mark the downdraft
opening.
4. Remove cooktop from countertop.
5. Cut downdraft opening. Be careful not to chip edges of coun-
tertop.
MOUNT THE UNIT
1. Set downdraft into opening. Extend leveling brackets to floor
of cabinet so downdraft sits straight. (Note: Leveling brackets
can be removed and re-attached in other positions. Bottom
flange may have to face inward in tight cabinet installations.)
2. Secure the downdraft to the countertop as follows: Hold the
downdraft against the back of countertop cut-out and tightening
the 2 mounting screws (one on each end of unit) on underside
of countertop. Use a wood shim between screw and underside
of granite countertops.
3. Screw leveling brackets to bottom of cabinet. Tighten screws
holding leveling bracket to unit on each side.


Specyfikacje produktu

Marka: Broan
Kategoria: Okap wyciągowy
Model: 273003

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z Broan 273003, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje Okap wyciągowy Broan

Broan

Broan Elite RMIP45 Instrukcja

4 Października 2024
Broan

Broan Elite 619004 Instrukcja

4 Października 2024
Broan

Broan BWS1304SS Instrukcja

4 Października 2024
Broan

Broan EWS1306BLS Instrukcja

4 Października 2024
Broan

Broan BWP1304SS Instrukcja

4 Października 2024
Broan

Broan PM250 Instrukcja

4 Października 2024
Broan

Broan Elite 614804EX Instrukcja

4 Października 2024
Broan

Broan BWP1364SS Instrukcja

4 Października 2024
Broan

Broan BC4130SS Instrukcja

4 Października 2024
Broan

Broan BBN3306SSC Instrukcja

4 Października 2024

Instrukcje Okap wyciągowy

Najnowsze instrukcje dla Okap wyciągowy

Pelgrim

Pelgrim ISW990 Instrukcja

15 Października 2024
PKM

PKM 6080X Instrukcja

15 Października 2024
M-System

M-System MSPK 761 IX Instrukcja

15 Października 2024
Pelgrim

Pelgrim ISWA991RVS Instrukcja

15 Października 2024
Pelgrim

Pelgrim ISW751RVS Instrukcja

15 Października 2024
Pelgrim

Pelgrim ISW771RVS Instrukcja

15 Października 2024
Amana

Amana WVW53UC6HV Instrukcja

15 Października 2024
Haier

Haier HPH60IMB2 Instrukcja

15 Października 2024
Haier

Haier HC60BMB2 Instrukcja

15 Października 2024
Haier

Haier HPH90IMB2 Instrukcja

15 Października 2024