DESCRIPTION
The VAR1Voice-Activated Relay is a DPDT relay device that is
activated when an audio signal is detected at the microphone pre-
amp or at 70V, 25V, or 600-ohm line level inputs. It has a number
of useful applications, such as muting a sound system in response
to a microphone or telephone page, activation of accessory (secu-
rity) equipment, or activation of a zone paging module.
A slide switch is included to select the pre-amp or the line inputs.
The VOX detect circuit also includes volume, sensitivity, and delay
controls. The audio output is an isolated 600-ohm transformer.
The unit operates from a DC power source (not included).
INSTALLATION
Set input source switch on the top side of the unit to LINE if
using one of the line inputs or to MIC if using a microphone.
Connect a power supply to the 2 to 24V DC jack on the top of1
the unit or to the + and - screw terminals. The Bogen model
PRS40C power supply is recommended.
WIRING
Refer to the block diagrams and the sample wiring diagrams on
the next page to wire the VAR1for your application.
OPERATION
Sensitivity can be adjusted according to the needs of the applica-
tion. Clockwise rotation of the control increases sensitivity. Do
not over rotate the control or you may damage the trimpot.
The delay control is also adjustable in the field. The maximum
delay time is 25 seconds. Clockwise rotation of the control
increases delay time.
SPECIFICATIONS
LINE INPUT
Impedance: 600 ohms
Frequency Response: 00 Hz to 0 kHz1 1
70V Input Impedance: 200k ohms
Output Level: 400 m VRMS
25V Input Impedance: 75k ohms
Output Level: 420 m VRMS
MIC PREAMP
Gain: 62 dB
Sensitivity: 750 m VRMS for 1VRMS out
Distortion: <2%
Frequency Response: 200 Hz to 10 kHz
Output Signal-to-Noise Ratio: 55 dB
GENERAL
VOX Sensitivity: 20 mV - 50 m VRMS 1
@ 600 ohms Line input
Time Delay Range (approx.): 0.25 to 25 sec.
Relay Contact Rating: 2 amps/30V DC,
0.5 amp/120V AC
Power Requirements: External 2V to 24V DC @1
100 mA (not included)
SERVICE
There are no user serviceable components within the VAR1. The
warranty may become void if the unit is serviced by other than
an authorized Bogen service agency.
Contact the Bogen Applications Department if you have any
questions concerning VAR1applications.
©2003 Bogen Communications, Inc.
Specifications subject to change without notice.
54-5934-01D 0902
www.bogen.com
Limited Warranty; Exclusion of Certain Damages:
Bogen Voice-Activated Relay is warranted to be free from defects in material and workmanship for two (2) years from the date of sale to the original purchaser.
Any part of any Bogen product covered by this warranty that, with normal installation and use, becomes defective (as confirmed by Bogen upon inspection)
during the applicable warranty period, will be repaired or replaced by Bogen, at Bogenʼs option, provided the product is shipped insured and prepaid to: Bogen
Factory Service Department, 50 Spring Street, Ramsey, NJ 07446, USA. Repaired or replacement product will be returned to you freight prepaid. This warranty
does not extend to any of our products that have been subjected to abuse, misuse, improper storage, neglect, accident, improper installation or have been
modified or repaired or altered in any manner whatsoever, or where the serial number or date code has been removed or defaced.
THE FOREGOING LIMITED WARRANTY IS BOGENʼS SOLE AND EXCLUSIVE WARRANTY AND THE PURCHASERʼS SOLE AND EXCLUSIVE REME-
DY. BOGEN MAKES NO OTHER WARRANTIES OF ANY KIND, EITHER EXPRESS OR IMPLIED, AND ALL IMPLIED WARRANTIES OF MER-
CHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY DISCLAIMED AND EXCLUDED TO THE MAXIMUM EXTENT ALLOWABLE
BY LAW. Bogen's liability arising out of the manufacture, sale or supplying of products or their use or disposition, whether based upon warranty, contract, tort
or otherwise, shall be limited to the price of the product. IN NO EVENT SHALL BOGEN BE LIABLE FOR SPECIAL, INCIDENTAL OR CONSEQUENTIAL
DAMAGES (INCLUDING, BUT NOT LIMITED TO, LOSS OF PROFITS, LOSS OF DATA OR LOSS OF USE DAMAGES) ARISING OUT OF THE MANU-
FACTURE, SALE OR SUPPLYING OF PRODUCTS, EVEN IF BOGEN HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES OR LOSSES.
Some States do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. This
warranty gives you specific legal rights, and you may also have other rights which vary from State to State.
Products that are out of warranty will also be repaired by the Bogen Factory Service Department -- same address as above or call 201-934-8500. The parts
and labor involved in these repairs are warranted for 90 days when repaired by the Bogen Factory Service Department. All shipping charges in addition to
parts and labor charges will be at the owner's expense. All returns require a Return Authorization number. For most efficient warranty or repair service, please
include a description of the failure.
Products manufactured and labeled by other companies may be covered by warranties offered by such companies. Please call Bogen Customer Service or
refer to product packaging for manufacturerʼs warranty for non-Bogen branded products.
12/2008
VOICE-ACTIVATED RELAY
Model VAR1
VAR1used with amplifiers to mute music during
a telephone page (paging port without contact closure).
VAR1used in a security system to activate an amplifier, CCTV, and light relay control.
VAR1for connecting a Paging Port to a ZPM3.
VAR1Block Diagram


Specyfikacje produktu

Marka: Bogen
Kategoria: Niesklasyfikowane
Model: VAR1

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z Bogen VAR1, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje Niesklasyfikowane Bogen

Bogen

Bogen VAR1 Instrukcja

7 Października 2024
Bogen

Bogen AH5A Instrukcja

7 Października 2024
Bogen

Bogen ADP1 Instrukcja

7 Października 2024
Bogen

Bogen SPT5A Instrukcja

7 Października 2024
Bogen

Bogen SPT15A Instrukcja

7 Października 2024
Bogen

Bogen SPT30A Instrukcja

7 Października 2024
Bogen

Bogen TBL1S Instrukcja

4 Października 2024
Bogen

Bogen BCIRS Instrukcja

24 Września 2024
Bogen

Bogen SAX1R Instrukcja

23 Września 2024

Instrukcje Niesklasyfikowane

Najnowsze instrukcje dla Niesklasyfikowane

Stihl

Stihl HT 70 Instrukcja

15 Października 2024
Ernesto

Ernesto H14270 Instrukcja

15 Października 2024
Uniden

Uniden BT MIC KIT Instrukcja

15 Października 2024
Vaude

Vaude Omnis Bike 26 Instrukcja

15 Października 2024
ART

ART ProChannel II Instrukcja

15 Października 2024
Aukey

Aukey DR02J Instrukcja

15 Października 2024
Master Lock

Master Lock 653EURD Instrukcja

15 Października 2024
Roland

Roland FR-18 Diatonic Instrukcja

15 Października 2024