Instrukcja obsługi Baracuda Supra Eco 3

Baracuda Przepych Supra Eco 3

Przeczytaj poniżej 📖 instrukcję obsługi w języku polskim dla Baracuda Supra Eco 3 (16 stron) w kategorii Przepych. Ta instrukcja była pomocna dla 3 osób i została oceniona przez 2 użytkowników na średnio 4.5 gwiazdek

Strona 1/16
H0766100_REVA
SUPRA ECO 3
Installation & Operating Instructions
Baracuda® SUPRA ECO 3 | Installation and Operating Instructions
2
Refer to the following websites for information on warranty and service in your country:
Australia, NZ, Asia and South Pacific go to www.baracuda.com.au
Date of Installation ____________________
Installer Information _____________________________________________________________
Initial Pressure Gauge Reading (with clean filter) ___________________________________
Pump Model Horsepower __________________________ __________________________
Filter Model ___________________________ _______________________________________
Control Panel Model Serial Number ___________________ ________________________
Notes ___________________________________________________________________________
__________________________________________________________________________________
EQUIPMENT INFORMATION RECORD
Table of Contents
Section 1. Important Safety Instructions 3 .....
Section 2. Installation 7 ......................................
2.1 Location Requirements 7 ...................................
2.2 Hydraulic Connections 7 ....................................
2.3 Electrical Connection 8 .....................................
Section 3. Operation 8 .......................................
3.1 Operating Principle 8 .........................................
3.2 Operating the Pump 8 .......................................
3.3 User Interface .................................................. 9
3.4 Pump Speeds 9 ..................................................
3.5 Pump Shutdown and Reset...........................10
3.6 Priming the Pump 10 ..........................................
Section 4. Maintenance 10 ................................
4.1 Routine Maintenance 10 .....................................
4.2 General Maintenance Information 11 ..............
4.3 Winterising ...................................................... 11
4.4 Servicing .........................................................12
Section 5. Repair Parts 12 .................................
Section 6. Troubleshooting 13 ...........................
6.1 Appliance Behaviour 13 ......................................
6.2 Error Codes 14 .....................................................
Section 7. Pump Parts 15 ...................................
Baracuda® SUPRA ECO 3 | Installation and Operating Instructions
3
Section 1. Important Safety Instructions
WARNING
READ AND FOLLOW ALL INSTRUCTIONS
All electrical work must be performed by a licensed electrician and conform to all national,
state, and local codes. When installing and using this electrical equipment, basic safety
precautions should always be followed, including the following:
RISK OF SUCTION ENTRAPMENT HAZARD,
WHICH, IF NOT AVOIDED, CAN RESULT IN
SERIOUS INJURY OR DEATH.
Do not block pump suction, as this can cause severe injury or death. Do not use this pump for
wading pools, shallow pools, or spas containing bottom drains, unless the pump is connected
to at least two (2) functioning suction outlets. Drain covers must be certified to the latest
published edition of ANSI/ASME A112.19.8 or its successor standard ANSI/APSP-16.
In Australia AS1926.3 is also an acceptable standard.
A check valve can interfere with the proper operation of certain Suction Vacuum Release System
(SVRS) products. To avoid possible entrapment hazard, serious injury, or death, make sure to review
the operation/owner's manual of your particular SVRS product before installing the check valve.
To reduce the risk of injury, do not permit children to use this product.
To reduce the risk of property damage or injury, do not attempt to change the backwash
(multiport, slide, or full flow) valve position with the pump running.
Baracuda pumps are powered by a high-voltage electric motor and should be installed by a
licensed or certified electrician or a qualified swimming pool service technician.
The pump is for fixed installations only and to be used in conjunction with swimming
pool equipment (e.g., filters). The pump is to be installed in accordance with the relevant
requirements of the Australian wiring rules AS/NZS 3000. Also refer to the installation
instructions relating to the swimming pool equipment for which the pump will be an integral
part. The pump is to be supplied through a residual current device (RCD) with a rated
residual operating current of 30 mA. If the supply cord is damaged it must be replaced by the
manufacturer or its service agent or similarly qualified person in order to avoid hazard. Only a
qualified person/s, should perform repairs and/or maintenance work on the pump and motor,
including any cabling work to the motor.
Incorrectly installed equipment may fail, causing severe injury or property damage.
Do not connect system to an unregulated city water system or other external source of
pressurized water producing pressures greater than 250 KPA (35 PSI). Trapped air in the
system can cause the filter lid to be blown off, which can result in death, serious personal injury,
or property damage. Be sure all air is out of the system before operating.
To minimize risk of severe injury or death, the filter and/or pump should not be subjected to the piping
system pressurization test. Local codes may require the pool piping system to be subjected to a
pressure test. These requirements are generally not intended to apply to the pool equipment, such as
lters or pumps. Baracuda pool equipment is pressure tested at the factory. If, however, the WARNING
cannot be followed, pressure testing of the piping system must include the filter and/or pump.


Specyfikacje produktu

Marka: Baracuda
Kategoria: Przepych
Model: Supra Eco 3

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z Baracuda Supra Eco 3, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje Przepych Baracuda

Baracuda

Baracuda Hydra+ Instrukcja

18 Września 2024
Baracuda

Baracuda Supra Eco Instrukcja

17 Września 2024

Instrukcje Przepych

Najnowsze instrukcje dla Przepych

Ozito

Ozito PTP-012A Instrukcja

15 Października 2024
MSW

MSW -AN-100 Instrukcja

15 Października 2024
MSW

MSW -MN34 Instrukcja

15 Października 2024
MSW

MSW -MN34M Instrukcja

15 Października 2024
MSW

MSW -AOP40S Instrukcja

15 Października 2024
Nefit

Nefit VentiLine Instrukcja

12 Października 2024
Liberty Pumps

Liberty Pumps 250 Instrukcja

9 Października 2024
Liberty Pumps

Liberty Pumps 457 Instrukcja

9 Października 2024
Liberty Pumps

Liberty Pumps 230 Instrukcja

9 Października 2024