OM7
OVERVIEW:
Designed, assembled and tested by Audix in the USA, the OM7 is a
dynamic vocal microphone used for professional sound companies,
front of house and mixing engineers, and high prole xed installations.
The OM7 is known for its ability to provide unprecedented gain before
feedback on concert level stages without sacricing sound quality. In
addition, the OM7 is very resistant to feedback on extremely loud stages,
and for performers who tend to “cup” the microphone with both hands.
In order to achieve these extraordinary performance benets, the OM7
is designed with an unconventionally low output level (8-10 dB lower
than typical dynamic microphones). This low gain stage acts as a natural
“pad” at the capsule in order to maintain high delity at the source.
For this reason, the OM7 is best suited for use with high quality mixing
consoles with plenty of head room to compensate for the low gain.
The OM7 is characterized with a super-tight hypercardioid polar pattern
which effectively isolates the vocals from the rest of the instruments on
stage. With a wide frequency range of 48 Hz - 19 kHz, the OM7 employs
a VLM™ (Very Low Mass) diaphragm for a very clean and punchy sound
with exceptional transient response.
Well balanced, comfortable to hold and durable, the OM7 is
manufactured with very high standards and tight tolerances. Roadworthy
construction includes a precision die cast zinc alloy body, black e-
coat nish, laser etched model and serial number, steel mesh grill,
Switchcraft® XLR connector, and heavy duty nylon clip.
FEATURES:
Studio quality sound
Low gain stage acts as natural pad
Unprecedented gain before feedback
Handles high SPL without distortion
Low handling noise
Provides exceptional vocal isolation on stage
Dent resistant steel spring grill
5 year warranty
APPLICATIONS:
Lead or backing vocals
Live recording
Broadcast
Home studio - vocal and instrument
Sax, brass, guitar, dobro, flute, percussion, drums
SUPPLIED ACCESSORIES:
Heavy duty nylon mic clip (MC1)
Carrying pouch (P1)
OPTIONAL ACCESSORIES:
WS357 - External foam windscreen
CBL20 - 20’ XLR-XLR mic cable
DYNAMIC VOCAL MICROPHONE
MC1 WS357 CBL20
Transducer Type Dynamic
Frequency Response 48 Hz - 19 kHz
Polar Pattern Hypercardioid
Output Impedance 150 ohms
Off Axis Rejection > 30 dB
Maximum SPL ≥144 dB
Power Requirements None
Connector Switchcraft® male
XLR connector
Polarity Positive pressure on diaphragm
produces positive voltage on pin 2
relative to pin 3 of output
XLR connector
Housing / Finish Zinc Alloy /
Black E-coat
Length 176 mm / 6.9 inches
SPECIFICATIONS: ARCHITECTS AND ENGINEERS SPECIFICATIONS:
The microphone shall be of the dynamic type and the polar pattern of the microphone
shall be hypercardioid. The nominal output impedance shall be equal to 150 ohms at
1 kHz.The microphone shall have a sensitivity of 0.8 mV / Pa at 1 kHz and a sound
pressure level ≥144 dB. The microphone body shall be of die cast zinc alloy and the
grill cap shall be steel wire mesh. The overall dimensions shall be 23 mm in diameter
at the base, 53 mm in diameter at the widest point on the grill and 176 mm in length.
The microphone shall be the Audix OM7.
OPERATION:
The OM7 is a low impedance microphone and should be plugged into the “mic level”
input of your console, mixer, or recording device. Please note that your microphone
does not require phantom power and will not be effected in any way by phantom
power should it be running simultaneously while the microphone is in operation. Avoid
plugging or unplugging the microphone from the PA system unless the channel is
muted or the volume of the system turned down. Failure to do so may result in a loud
“popping” noise which could seriously damage the speakers in the PA system.
USER TIPS:
The OM7 is designed with an unconventionally low output level; this means that the
gain will have to be compensated on the mixing console or mic preamp. The OM7 has
the tightest pick-up pattern of any microphone on the market in order to help eliminate
sound from other instruments on stage from “bleeding” into the microphone. For best
results, it is important to sing directly into the mic as close as possible (within 1-inch)!
When using oor monitors, position the microphone so that it is parallel to the oor.
When using multiple microphones on a live performance stage, allow a distance of 2-3
feet between mics to avoid phase issues.
*Further miking techniques may be found on our website at www.audixusa.com
www.audixusa.com Call: 503-682-6933 Fax: 503-682-7114
Audix Corporation 9400 SW Barber Street, Wilsonville, OR 97070
SERVICE AND WARRANTY:
This microphone is under warranty for
a period of 5 years from any and all
manufacturing defects. Should your
microphone fail in any way, please con-
tact the Audix Service department at
503-682-6933. A Return Authorization
number is required before returning
any products.
CARE AND MAINTENANCE:
The OM7 is manufactured to exacting specs
with roadworthy construction. However, the
capsule is highly sensitive and should be
handled with care. Avoid extreme temperatures
and be sure to store your microphone in the
pouch provided when not in use. Moisture of
any kind can adversely affect the sound and
performance of your microphone.
FREQUENCY / POLARS:
To register your
microphone, please visit
www.audixusa.com
***All specications subject to change without notice.
DIMENSIONS (mm):


Specyfikacje produktu

Marka: Audix
Kategoria: mikrofon
Model: OM7

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z Audix OM7, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje mikrofon Audix

Audix

Audix M63 Instrukcja

8 Października 2024
Audix

Audix M45 Shortgun Instrukcja

8 Października 2024
Audix

Audix M55D Instrukcja

4 Października 2024
Audix

Audix M40 Instrukcja

2 Października 2024
Audix

Audix M55WO Instrukcja

23 Września 2024
Audix

Audix M40W12HC Instrukcja

22 Września 2024
Audix

Audix OM2 Instrukcja

22 Września 2024
Audix

Audix Fireball Instrukcja

22 Września 2024
Audix

Audix M55W Instrukcja

22 Września 2024
Audix

Audix TM1 Instrukcja

22 Września 2024

Instrukcje mikrofon

Najnowsze instrukcje dla mikrofon

Audio-Technica

Audio-Technica BP4073 Instrukcja

15 Października 2024
Power Dynamics

Power Dynamics PD524 Instrukcja

15 Października 2024
Audio-Technica

Audio-Technica AT4060 Instrukcja

14 Października 2024
Pyle

Pyle PDWM8225 Instrukcja

13 Października 2024
AKG

AKG WMS420 Instrukcja

13 Października 2024
Audio-Technica

Audio-Technica BP892xCH Instrukcja

12 Października 2024
Apart

Apart MDS.DEL Instrukcja

10 Października 2024
BOYA

BOYA BY-V4 Instrukcja

9 Października 2024