Instrukcja obsługi Argoclima SOFTY PLUS

Argoclima klimatyzacja SOFTY PLUS

Przeczytaj poniżej 📖 instrukcję obsługi w języku polskim dla Argoclima SOFTY PLUS (11 stron) w kategorii klimatyzacja. Ta instrukcja była pomocna dla 14 osób i została oceniona przez 2 użytkowników na średnio 4.5 gwiazdek

Strona 1/11
13V 02/16
PORTABLE AIR CONDITIONER (LOCAL)
OPERATING INSTRUCTIONS
Read the instructions carefully before operating the appliance or carrying out maintenance work.
Observe all the safety instructions; failure to observe the instructions may lead to accidents and/or
damage. Store these instructions in a safe place for future reference.
EN
14V 02/16
GENERAL OPERATING AND SAFETY INSTRUCTIONS
This appliance is a portable air conditioner designed for domestic use.
Only use this air conditioner as described in this manual.
Ensure that the required voltage and frequency (220-240 V/50 Hz) match the available power source.
Ensure that the electricity system is ed by the air conditioner, in addition to thable to deliver the operating current requir at
normally absorbed by other appliances (electrical appliances, lighting system, etc.). Please refer to the maximum power
input data shown on the air conditioner's data plate.
Connection to the electricity grid must take place in accordance with current installation standards.
Ensure that the automatic switches and system protection valves are able to withstand a start-up current of 6A (normally
for less than 1 second).
The power socket must always include an efficient earth connection.
Make sure that the plug is properly inserted into the socket. Do not use multiple adapters. Do not touch the plug with wet
hands. Make sure that the plug is clean.
Do not use the plug for starting/stopping the air conditioner: use the ON/OFF button on the remote control or control
panel instead.
Do not install the air conditioner in rooms potentially subject to water sprays (e.g. laundries).
This air conditioner can be used by children of 8 years or older and by persons with reduced physical, sensory and
mental abilities, or lacking the necessary experience and knowledge, provided they are supervised or instructed on its
use by a person responsible for their safety, so that they are fully aware of the attendant risks.
Do not allow the unit to be cleaned or serviced by unsupervised children.
Before moving or cleaning the appliance, ensure that it is unplugged from the socket.
Do not move the air conditioner while it is operating; first turn the appliance off, then check and remove any condensate
which may have formed.
To turn the appliance off, set the remote control to OFF and remove the plug from the socket. Pull on the plug only. Do
not pull the cord.
Do not use the appliance if the cord or plug are damaged. Contact a service centre to replace a damaged power
cord, so as to avoid any safety risks.
PRECAUTION!
Do not insert any objects into the air conditioner: this is very dangerous as the fan turns at high speed.
Ensure that air circulates freely around the unit. Do not cover the air intake and delivery grilles with drapes or
any other means.
WARNING!
The air conditioner must be positioned at least 50 cm from the wall or any other obstacles, on a flat and stable surface
so as to avoid water leaks.
The air conditioner is fitted with a system to protect the compressor from overload. This means that the
compressor only starts 3 minutes after its previous stoppage.
Please wait at least 3 minutes before starting the unit. This helps prevent the compressor from being damaged.
WARNING!
In the event of an anomaly, switch the appliance off and unplug from the socket. Do not dismantle or attempt to
repair or modify the product. In the event of a malfunction, contact the service centre directly.
WARNING!
Do not expose the air conditioner to direct sunlight, as the colour of the materials may change; moreover, the
appliance may overheat causing the protection mechanism to intervene and switch the appliance off.
Do not use insecticides, oils, detergents or spray paints near the appliance; do not use aggressive chemical
detergents to clean the casing: this may damage the finish and colour.
Close all open windows to maximise air conditioning efficiency.
The manufacturer will not be held liable if safety and accident prevention rules are not observed.
15V 02/16
DESCRIPTION OF THE APPLIANCE
FRONT VIEW
REAR VIEW
Min/max operating limits (internal temperature)
Cooling: 16 °C DB / 35 °C DB
Heating: 5 °C DB / 27 °C DB
Dehumidification: 16 °C DB / 35 °C DB
Cooling mode room temperature adjustment range: 16 °C DB / 32 °C DB
1) CONTROL PANEL AND BUTTONS FOR
OPERATION WITHOUT REMOTE CONTROL
2) FIN AND AIR FLOW OUTLET
3) SIGNAL RECEIVER
4) FRONT
5) HANDLES
6) AIR INTAKE
7) HANDLES
8) DRAINAGE HOLE (DEHUMIDIFICATION)
9) AIR INTAKE
10) DRAINAGE HOLE (ONLY FOR MODELS WITH
HEAT PUMP)
11) POWER CORD OUTLET
12) DRAINAGE HOLE (COOLING)
13) UPPER FILTER (BEHIND GRILLE)
14) UPPER AIR INTAKE
15) LOWER FILTER (BEHIND GRILLE)
16) LOWER AIR INTAKE
17) WHEELS
18) REMOTE CONTROL
9) A
1
(18)


Specyfikacje produktu

Marka: Argoclima
Kategoria: klimatyzacja
Model: SOFTY PLUS

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z Argoclima SOFTY PLUS, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje klimatyzacja Argoclima

Instrukcje klimatyzacja

Najnowsze instrukcje dla klimatyzacja

LG

LG HS-H076QPA0 Instrukcja

15 Października 2024
Klarstein

Klarstein Vita Pure 2G Instrukcja

15 Października 2024
Gree

Gree ETAC-15HP265V20B Instrukcja

15 Października 2024
Qlima

Qlima P 126 Instrukcja

14 Października 2024
Mitsubishi

Mitsubishi MSZ-CB22VA Instrukcja

14 Października 2024
Suntec

Suntec Motion 90+ Instrukcja

14 Października 2024
Danby

Danby DTAC120B1WDB Instrukcja

14 Października 2024
Amana

Amana PTC093K35AXXX Instrukcja

14 Października 2024
Amana

Amana AMAP121AB-2 Instrukcja

14 Października 2024