Instrukcja obsługi APSystems EZ1


Przeczytaj poniżej 📖 instrukcję obsługi w języku polskim dla APSystems EZ1 (20 stron) w kategorii panel słoneczny. Ta instrukcja była pomocna dla 13 osób i została oceniona przez 2 użytkowników na średnio 4.5 gwiazdek

Strona 1/20
APsystems EZ1 series Microinverters
(For EMEA)
APsystems Microinverter User Manual
©All Rights Reserved
ALTENERGY POWER SYSTEM Inc.
emea.APsystems.com
APsystems
Karspeldreef 8, 1101 CJ, Amsterdam, The Netherlands
EMAIL: info.emea@APsystems.com
APsystems
22 Avenue Lionel Terray 69330 Jonage France
EMAIL:info.emea@APsystems.com
Please scan this QR code to have
access to our APPs and Products
Information.
APsystems Microinverter EZ1 series User manual
Table of Contents
1. Important Safety Instructions.......................................................................................... 2
1.1 Safety Instructions ......................................................................................................................................2
1.2 Radio Interference Statement ................................................................................................................ 3
1.3 Symbols in lieu of words ......................................................................................................................... 4
2. APsystems Microinverter System Introduction...................................................... 5
3. APsystems Microinverter EZ1 series Introduction................................................ 7
4. APsystems Microinverter System Installation.........................................................8
4.1 Additional accessories supplied by APsystems ................................................................................. 8
4.2 Installation Procedures ............................................................................................................................ 8
4.2.1 Step 1 - Verify that grid voltage matches microinverter rating.........................................8
4.2.2 Step 2 - Install the microinverters in proper position ......................................................... 8
4.2.3 Step 3 - Connect APsystems Microinverters to the PV Modules.....................................9
4.2.4 Step 4 - Connect the APsystems microinverter to EU power cord...............................10
4.2.5 Step 5 - Cable Connection ....................................................................................................... 10
5.Install and Use AP EasyPower......................................................................................... 11
5.1 Install APP ..................................................................................................................................................11
5.2 Connect the APsystems Microinverters ............................................................................................ 11
5.3 Monitor & Control ...................................................................................................................................12
6. Troubleshooting.................................................................................................................... 13
6.1 Status Indications and Error Reporting..............................................................................................13
6.1.1 Start up LED...................................................................................................................................13
6.1.2 Operation LED ...............................................................................................................................13
6.1.3 GFDI Error ...................................................................................................................................... 13
6.2 Trouble Shooting Guide........................................................................................................................ 13
6.3 APsystems Technical Support ............................................................................................................. 13
6.4 Maintenance ............................................................................................................................................. 13
7. Replace a microinverter....................................................................................................14
8. Technical Data....................................................................................................................... 15
8.1 EZ1 series Microinverter Datasheet .................................................................................................... 16
9. EZ1 Accessory....................................................................................................................... 18
9.1 Dimensions ................................................................................................................................................ 18
9.2 Single Device ........................................................................................................................................... 20
9.3 Multiple Devices......................................................................................................................................19
APsystems Microinverter EZ1 series User manual
2
1. Important Safety Instructions
This manual contains important instructions to follow during installation and maintenance of the APsystems
Photovoltaic Grid-connected Microinverter. To reduce the risk of electrical shock and ensure a safe installation and
operation of the APsystems Microinverter, the following symbols appear throughout this document to indicate
dangerous conditions and important safety instructions.
Specifications are subject to change without notice. Please ensure you are using the most recent update found at
https://emea.apsystems.com/resources/library/
WARNING:
This indicates a situation where failure to follow instructions may cause a serious hardware failure or personnel
danger if not applied appropriately. Use extreme caution when performing this task.
NOTICE:
This indicates information that is important for optimized microinverter operation. Follow these instructions closely.
1.1 Safety Instructions
Perform all electrical installations in accordance with local electrical codes.
Before installing or using the APsystems Microinverter, please read all instructions and cautionary markings in
the technical documents and on the APsystems Microinverter system and the solar array.
Do NOT disconnect the PV module from the APsystems Microinverter without first disconnecting the AC power.
Be aware that the body of the APsystems Microinverter is the heat sink and can reach a temperature of 80°C.
To reduce risk of burns, do not touch the body of the Microinverter.
Do NOT attempt to repair the APsystems Microinverter. If the microinverter is suspected to be faulty, please
contact your local APsystems Technical Support to start troubleshooting and obtain a RMA (Return Merchandise
Authorization) number to start the replacement process if needed. Damaging or opening the APsystems
Microinverter will void the warranty.


Specyfikacje produktu

Marka: APSystems
Kategoria: panel słoneczny
Model: EZ1

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z APSystems EZ1, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje panel słoneczny APSystems

APSystems

APSystems EZ1 Instrukcja

7 Października 2024

Instrukcje panel słoneczny

Najnowsze instrukcje dla panel słoneczny

CyberPower

CyberPower SCUN25A Instrukcja

9 Października 2024
CyberPower

CyberPower SCUN60A Instrukcja

9 Października 2024
CyberPower

CyberPower CPS1500ESA24 Instrukcja

9 Października 2024
CyberPower

CyberPower CPSHB300ETR Instrukcja

9 Października 2024
CyberPower

CyberPower CPS3000EILCD Instrukcja

9 Października 2024
V-TAC

V-TAC VT-AU450-36V Instrukcja

8 Października 2024
V-TAC

V-TAC VT-450 Instrukcja

8 Października 2024
Xtorm

Xtorm XR2S28 Instrukcja

5 Października 2024