Instrukcja obsługi Apollo Ultrasonic Smart Alarm


Przeczytaj poniżej 📖 instrukcję obsługi w języku polskim dla Apollo Ultrasonic Smart Alarm (1 stron) w kategorii Sprzęt pomiarowy. Ta instrukcja była pomocna dla 5 osób i została oceniona przez 2 użytkowników na średnio 4.5 gwiazdek

Strona 1/1
STEP 1 - DETERMINE THE SHAPE OF YOUR OIL TANK
For tank types shown above, select the tank type that is closest in shape to your tank and complete the chart
above.
Note: For unusual tank shapes or to improve the accuracy of the Apollo Smart Monitor you may require a lookup/strapping table. This can be
obtained from your tank manufacturer. Once you have the appropriate informaon, please email it to support@dunravensystems.com. We will
then update the lookup/strapping table so it is compable with our equipment and send it back to you, with instrucons on how to import it into
your Apollo Smart Monitor.
Determine the dimensions of your tank either from manufacturer’s data for the tank or by physically
measuring to complete the chart.
You only need to note the dimensions indicated on the chart shown above.
For bunded tanks the informaon required is for the internal tank only, where the Apollo Smart Transmier
will be located.
To determine the tank height measure from the top of the tank, i.e. where the Apollo Smart Transmier will
be posioned, to the boom of the tank (N.B. of the internal tank in a bunded tank)
Determine the capacity of the tank from the manufacturer’s data for the brimful capacity.
STEP 2 – SETTING UP YOUR APOLLO SMART MONITOR
On rst powering your Apollo Smart Monitor automacally displays its setup mode. The Apollo Smart Monitor
screen will show SETUP 1. One or more segments of the display may be ashing. Flashing segments are circled
in RED in the diagrams. Please follow the steps below to store the sengs to congure your Apollo Smart
Monitor. If you make a mistake and store an incorrect value, simply press ENTER repeatedly unl you return to
the same SETUP number and then select the correct value and press ENTER to store.
SETUP 1 – Seng the me (hrs)
Adjust the hour displayed using
 / . Press ENTER to save.
SETUP 2 – Seng the me
(mins) Adjust minutes dis-
played using / . Press
ENTER to save.
Packaging contains:
Apollo Smart Monitor + mains plug
Apollo Smart Transmier + 2 self
tapping screws + weather seal
Apollo Smart Product manual
This installaon guide
SETUP 3 – Seng the tank type
Select Tank Type i.e. A, B, or C, using
 / to match the Type you noted
from above. Press ENTER to save.
SETUP 4 Seng the tank
capacity (Ltr) Refer to the
chart above for nominal capaci-
ty and adjust the amount in
Litres displayed using / .
Press ENTER to save.
SETUP 5 – Seng the tank height (cm)
Refer to the chart above for tank
height and adjust the amount in cm
displayed using  /. Press ENTER to
save. Note that if Tank Type ‘A’ was
selected, SETUP 6 will be skipped.
SETUP 6 (Type B & C tanks only) -
Seng the tank width (cm)
Refer to the tank chart above for
the width and adjust the amount
in cm displayed using / . Press
ENTER to save.
N.B. If you cannot select the correct dimensions for your tank, conrm that you have selected the correct tank type.
Tips
When taking the tank
dimensions, conrm
tank is prepared for
STEP 4
Have a previous oil bill
handy or call your oil
dealer to nd out
today’s oil cost per
litre.
INSTALLATION GUIDE
Do NOT install/ t your Apollo Smart Transmier to the tank at this me.
Tank Type
Height
(H) cms
Width
(W) cms
Brimful
Capacity
(Ltrs)
Your tank
dimension chart
N/A
Type B - (H >= W) Oval/
cylindrical horizontal
Type A - Rectangular/
cylindrical vercal
Type C - (W > H) Lo prole
STEP 2 – SETTING UP YOUR APOLLO SMART MONITOR—cont’d
SETUP 7 Seng the fuel cost per litre. Adjust the amount displayed
using /
. Press ENTER to save. (You may need to consult you last
oil bill or your oil supplier)
SETUP 8 – Seng the Fuel The and Low Level Audi-
ble Alarm: Alarm on: The Apollo Smart Monitor will
sound an audible alarm when it detects a sudden drop
in fuel level. It also sounds an audible beep when the
fuel level falls to below 5% of usable fuel remaining.
Alarm o: Disengages all alarms.
For further informaon please refer to Secon 6 of
the Product manual.
Select AL ON/OFF using /
. When the display
shows your preferred seng press ENTER to save.
The SETUP should now be complete. Press SETUP to exit and progress to STEP 3.
On exing SETUP mode the Apollo Smart Monitor temporarily displays CALC.
N.B. If at any stage you exit SETUP mode for any reason, to re-enter simply hold SETUP for 3 seconds and begin again.
STEP 3 - MATCHING THE APOLLO SMART TRANSMITTER TO THE SMART MONITOR
The Apollo Smart Monitor must be in LEARN mode which can be entered in one of two ways:
A) Pressing SETUP aer compleng STEP 2 above
B) By disconnecng and reconnecng the power
When in LEARN mode the display showsLrn’ in
the main display area. See image 1. LEARN
mode will last for 2 minutes during which me
you must ‘match/pair’ the Apollo Smart Trans-
mier to the Apollo Smart Monitor.
To match/pair the units: Firstly, note the loca-
on of the alignment pin on the right hand side
of the base of the Smart Monitor. See Image 2.
Using the screw hole of the Apollo Smart Trans-
mier slot it onto the pin as shown in Image 3.
The display of the Apollo Smart Transmier
should be facing in the same direcon as the
Apollo Smart Monitor’s display as shown in
Image 4.
When located properly, the bars in the bar
graph display, of both the Apollo Smart Moni-
tor and the Apollo Smart Transmier will ash
and begin to increase in synch together rising
from one bar to ten bars. A connuous audible
beep and ashing LED on the monitor will also
indicate the matching is in progress. Connue
to hold the units in place unl all 10 bars are
ashing. The Apollo Smart Monitor will make
a loud beep. The Red LED on the Apollo Smart
Transmier will ash. They are now matched
and should be separated immediately.
Following the ‘matching/pairing’ the Apollo Smart Transmier will send data connuously to the Apollo
Smart Monitor for approximately 10 minutes. Each me the Apollo Smart Monitor receives a reading, it will
make a clicking noise and the LED on the Apollo Smart Monitor will blink (this is ‘fast’ mode for the trans-
mier).
During this me conrm that the matching procedure was successful by slowly raising and lowering the Apol-
lo Smart Transmier over a at surface and observing that the display in the Apollo Smart Monitor changes .
‘Fast’ mode will stop aer 10 minutes. The Apollo Smart Transmier is now ready to t onto the tank and
should be ed whilst in ‘Fast’ mode.
You should now proceed immediately to STEP 4 and t the Apollo Smart Trans-
mier to your tank. If it is not ed within 10 minutes, the Apollo Smart Monitor
may display an error or an incorrect reading. It may then take up to 2 hours before
the correct tank level informaon is displayed on the Apollo Smart Monitor screen.
Image 3: Correct posioning Image 4 : Alignment
Image 2: Alignment Pin Image 1: ‘Lrn’ mode
STEP 4 INSTALLING THE APOLLO SMART TRANSMITTER ON THE TANK-
The procedure is the same for ng to both old and new tanks. For bunded
tanks ensure that the Apollo Smart Transmier is located on top of the inner
tank.
For Tank with pre drilled 30/32mm hole-
Remove cap from hole and insert transmier, ensuring the weather seal is
securely in place.
Ensure the transmier is vercal on top of the tank
Tighten on to the tank using the 2 stainless steel 19mm long self tapping -
screws supplied. Do not use longer screws. Do not over ghten.-
For Tank without pre drilled holes-
If tank is not pre-drilled, then using a 30/32mm hole saw, drill hole in top of the tank in a suitable area
to allow ease of ng of the transmier and in an area that the transmier can see the tank contents.
Posion so that there are no internal obstrucons, (i.e. Ribs, Stays, Side of Tank, internal equipment),
that may interfere with the ultrasonic signal.
Use Installaon Help Diagram below to ensure suitable ng.
Ensure the transmier is vercal on top of the tank
Tighten on to the tank using the 2 stainless steel 19mm long self tapping screws supplied. -Do not use
longer screws. Do not over ghten.-
Check the Apollo Smart Monitor display two hours aer mounng the transmier and verify that your Apollo
Smart Monitor display shows the tank level in the bar graph area and the oil volume informaon in the main -
display area. If this is not the case consult the ‘Troubleshoong’ secon of the Apollo Smart Product Manual.
N.B. the bar graph displays on the Apollo Smart Transmier and the Apollo Smart Monitor -
may not be the same. The transmier display indicates the top 1m of the tank while the
Apollo Smart Monitor bar-graph displays the oil level relave to the overall tank height.
STEP 5 (OPTIONAL) PERFORM -
ONLY IF THERE WAS A DELAY IN
INSTALLING THE APOLLO SMART
TRANSMITTER ON THE TANK
You only need to complete this step if there was a gap of
more than an hour between compleng STEP 3 and STEP 4.
STEP 5 is otherwise completed automacally as part of STEP
3.
When your Apollo Smart Transmier is installed and has
been conrmed as working reset the usage calculaons by
pressing SETUP for 3 seconds to enter SETUP mode and then
press ENTER repeatedly unl SETUP 9 is shown.
The segments at the boom of the
display will be ashing. Press the
ENTER key for 5 seconds. The screen
will temporarily show ‘CALC and then
returns to showing SETUP Seng 1 -
the Time (hrs). Press SETUP to leave
SETUP mode.
Setup of your Apollo Smart Monitor is
now complete and will now begin to it
monitor and track your oil consump-
on on a day to day and week to week
basis. On the ‘Days to Empty’ CUR-
RENT informaon screen, will be ---
displayed for 1 week.
Don’t forget to register your warranty!
www.dunravensystems.com
Should you have any queries, please refer to our FAQ secon of the website or
complete our online enquiry form.
The contents and images in this guide are subject to copyright and may not be reproduced without the permission of Dunraven
9-5538- 03


Specyfikacje produktu

Marka: Apollo Ultrasonic
Kategoria: Sprzęt pomiarowy
Model: Smart Alarm

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z Apollo Ultrasonic Smart Alarm, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje Sprzęt pomiarowy Apollo Ultrasonic

Instrukcje Sprzęt pomiarowy

Najnowsze instrukcje dla Sprzęt pomiarowy

Stamos

Stamos S-LS-28 Instrukcja

15 Października 2024
Stamos

Stamos S-LS-86 Instrukcja

15 Października 2024
Stamos

Stamos S-LS-61 Instrukcja

15 Października 2024
Stamos

Stamos S-LS-81 Instrukcja

15 Października 2024
Stamos

Stamos S-LS-84 Instrukcja

15 Października 2024
Stamos

Stamos S-LS-74 Instrukcja

15 Października 2024
Stamos

Stamos S-LS-76 Instrukcja

15 Października 2024
Stamos

Stamos S-LS-42 Instrukcja

15 Października 2024
Stamos

Stamos S-LS-75 Instrukcja

15 Października 2024
Stamos

Stamos S-LS-35 Instrukcja

15 Października 2024