Version 1.3 ©Copyright 2011, Ambient LLC. All Rights Reserved. Page 1
Ambient Weather WS-YG302A-Y Cherry Finish Cream
Dial Traditional Weather Station User Manual
Table of Contents
1. Introduction .................................................................................................................................... 2
2. Preparation ...................................................................................................................................... 2
3. Care and Cleaning .......................................................................................................................... 2
4. Hygrometer (Humidity Meter) ....................................................................................................... 3
4.1 How the hygrometer works .................................................................................................... 3
4.2 Hygrometer Accuracy ............................................................................................................. 3
5. Aneroid Barometer ......................................................................................................................... 3
5.1 How the aneroid barometer works ......................................................................................... 3
5.2 ading the barometer Re ............................................................................................................ 3
5.3 Absolute vs. Relative Pressure ...................................................................................................... 4
5.4 Barometer Calibration ............................................................................................................ 4
6. Dial Thermometer .......................................................................................................................... 5
7. Installation ...................................................................................................................................... 5
8. Measurement Specifications ........................................................................................................... 5
9. Troubleshooting Guide ................................................................................................................... 6
10. Liability Disclaimer ........................................................................................................................ 8
11. Warranty Information ..................................................................................................................... 9
12. California Prop 65 .......................................................................................................................... 9
Version 1.3 ©Copyright 2011, Ambient LLC. All Rights Reserved. Page 2
1. Introduction
Thank you for your purchase of the Ambient Weather -YG302A-Y Cherry Finish Brass Dial WS
Traditional Weather Station. The following is a guide for preparation, care and operation of your
traditional weather station.
Figure 1
Note: Barometric pressure readings, under normal conditions, only fluctuate between 1-1.25 inHg per
day. Not to be confused with +/- 1-1.25. So, the needle may never actually reach either forecast icon.
2. Preparation
Your weather instrument includes a protective pad to prevent damage to the barometer glass case during
shipment. Remove this protective pad and circular instruction sheet. The barometer is ready to use.
For accurate barometric pressure readings, please see Section 5.4 below Barometer Calibration.
3. Care and Cleaning
The solid wood case is finished with a clear, satin lacquer to protect and preserve the appearance.
Although occasional use of a good furniture polish is acceptable, we recommend periodic cleaning with
a very lightly water dampened soft cloth. Be sure to wipe the wood dry with a soft cloth before
cleaning.
Avoid use of harsh household cleaners and coarse paper towels, which can damage the lacquer coating
or scratch the bezel or lens. Fingerprints and dirt may be removed the lenses and bezels with a soft cloth
lightly dampened with a mixture of water and mild dishwashing liquid. Be sure to dry the lens and
bezel with a soft cloth after cleaning.
Do not install the weather station outside. The weather station is intended for indoor use only.
Version 1.3 ©Copyright 2011, Ambient LLC. All Rights Reserved. Page 3
4. Hygrometer (Humidity Meter)
4.1 How the hygrometer works
The hygrometer measures the indoor relative humidity. The sensor measures the air moisture by a
sensitive mechanical coil spring that is bonded with a moisture absorbent material.
Hygrometers register the percentage of water vapor present in the air, compared to the maximum amount
that can be present at a given temperature.
The coils in hygrometers respond slowly and while humidity levels change abruptly, it can take an hour
or more for the meter to reach an accurate reading. Remember that the hygrometer is reading indoor
humidity, and is vastly different than outdoor humidity, as reported by the National Weather Service.
It is not uncommon to have low humidity reading during cold weather when indoor air is heater. Air
conditioning also removes moisture from the air. The optimum levels are 45% to 50% during heating
and cooling seasons. Low humidity can cause health problems and can be hard on wood furnishings.
High humidity can cause mold or mildew to grow.
4.2 Hygrometer Accuracy
Humidity measurement is among the more difficult problems in basic meteorology. Accuracy is difficult
to achieve and are subject to drift, so need regular recalibration.
A further difficulty is that most hygrometers sense relative humidity rather than the absolute amount of
water present, but relative humidity is a function of both temperature and absolute moisture content, so
small temperature variations within the air in a test chamber will translate into relative humidity
variations.
5. Aneroid Barometer
5.1 How the aneroid barometer works
An aneroid barometer uses a small, flexible metal box called an aneroid cell. This aneroid capsule (cell)
is made from an alloy of beryllium and copper. The evacuated capsule (or usually more capsules) is
prevented from collapsing by a strong spring. Small changes in external air pressure cause the cell to
expand or contract. This expansion and contraction drives mechanical levers such that the tiny
movements of the capsule are amplified and displayed on the face of the aneroid barometer. Many
models include a manually set needle which is used to mark the current measurement so a change can
be seen. It was invented by Blaise Pascal.
5.2 Reading the barometer
It is highly advisable to lightly tap the glass near the center brass knob with your fingers before taking
a barometer reading. The light tap will overcome any friction that may affect accurate hand readings,
especially during periods of slow atmospheric changes. The Coast Guard has informed us that tapping
the barometer is even required on the most expensive aneroid barometers, because the mechanism is
made deliberately “stiff”.
The ability if the barometer to indicate changes in barometric pressure makes it a useful instrument in
weather forecasting.


Specyfikacje produktu

Marka: Ambient Weather
Kategoria: Niesklasyfikowane
Model: WS-YG302A-Y

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z Ambient Weather WS-YG302A-Y, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje Niesklasyfikowane Ambient Weather

Instrukcje Niesklasyfikowane

Najnowsze instrukcje dla Niesklasyfikowane

Stihl

Stihl HT 70 Instrukcja

15 Października 2024
Ernesto

Ernesto H14270 Instrukcja

15 Października 2024
Uniden

Uniden BT MIC KIT Instrukcja

15 Października 2024
Vaude

Vaude Omnis Bike 26 Instrukcja

15 Października 2024
ART

ART ProChannel II Instrukcja

15 Października 2024
Aukey

Aukey DR02J Instrukcja

15 Października 2024
Master Lock

Master Lock 653EURD Instrukcja

15 Października 2024
Roland

Roland FR-18 Diatonic Instrukcja

15 Października 2024