Instrukcja obsługi Airwell MFH - Mobile
Airwell
Airconditioner
MFH - Mobile
Przeczytaj poniżej 📖 instrukcję obsługi w języku polskim dla Airwell MFH - Mobile (20 stron) w kategorii Airconditioner. Ta instrukcja była pomocna dla 6 osób i została oceniona przez 2 użytkowników na średnio 4.5 gwiazdek
Strona 1/20
IMPORTANT NOTE:
Read this manual carefully before installing or operating your new air conditioning unit. Make sure to
save this manual for future reference.
MFH/MFR1-20190110-Rev1
Installation Manual
MFH MFR - Mobile
R290 - Version 1
English Manual
Contents
Safety Precautions
Cautions
Warnings(for using R290/R32 refrigerant only)
Preparations
Installation
Operation
Maintenance
Faults Diagnosis
Design and Compliance Notes
Sociable Remark
2
3
4
8
9
12
15
16
17
18
-------------
-----------------
-----------------
-------------------
-----------------
---------------
---------------
-------------------
------
-----
1
Safety Precautions
-Installation must be performed according to the installation instructions. Improper installation
can cause water leakage, electrical shock, or fire.
-Use only the included accessories and parts, and specified tools for the installation. Using
non-standard parts can cause water leakage, electrical shock, fire, and injury or property damage.
-Make sure that the outlet you are using is grounded and has the appropriate voltage. The
power cord is equipped with a three-prong grounding plug to protect against shock. Voltage
information can be found on the nameplate of the unit.
-Your unit must be used in a properly grounded wall receptacle. If the wall receptacle you
intend to use is not adequately grounded or protected by a time delay fuse or circuit breaker
(the fuse or circuit breaker needed is determined by the maximum current of the unit. The
maximum current is indicated on the nameplate located on unit), have a qualified electrician
install the proper receptacle.
-Install the unit on a flat, sturdy surface. Failure to do so could result in damage or excessive
noise and vibration.
-The unit must be kept free from obstruction to ensure proper function and to mitigate safety hazards.
-DO NOT modify the length of the power cord or use an extension cord to power the unit.
-DO NOT share a single outlet with other electrical appliances. Improper power supply can
cause fire or electrical shock.
-DO NOT install your air conditioner in a wet room such as a bathroom or laundry room. Too
much exposure to water can cause electrical components to short circuit.
-DO NOT install the unit in a location that may be exposed to combustible gas, as this could cause fire.
-The unit has wheels to facilitate moving. Make sure not to use the wheels on thick carpet or to roll
over objects, as these could cause tipping.
-DO NOT operate a unit that it has been dropped or damaged.
-The appliance with electric heater shall have at least 1 meter space to the combustible materials.
-Do not touch the unit with wet or damp hands or when barefoot.
-If the air conditioner is knocked over during use, turn off the unit and unplug it from the main power
supply immediately. Visually inspect the unit to ensure there is no damage. If you suspect the unit
has been damaged, contact a technician or customer service for assistance.
-In a thunderstorm, the power must be cut off to avoid damage to the machine due to lightning.
-Your air conditioner should be used in such a way that it is protected from moisture. e.g.
condensation, splashed water, etc. Do not place or store your air conditioner where it can fall or be
pulled into water or any other liquid. Unplug immediately if it occurs.
-All wiring must be performed strictly in accordance with the wiring diagram located inside of the unit.
-The unit's circuit board(PCB) is designed with a fuse to provide overcurrent protection. The
specifications of the fuse are printed on the circuit board, such as: T 3.15A/250V, etc.
WARNING: To prevent death or injury to the user or other people and property damage,
the following instructions must be followed. Incorrect operation due to ignoring of
instructions may cause death, harm or damage.
This symbol indicates that ignoring instructions may cause death or serious injury.
2
Specyfikacje produktu
Marka: | Airwell |
Kategoria: | Airconditioner |
Model: | MFH - Mobile |
Potrzebujesz pomocy?
Jeśli potrzebujesz pomocy z Airwell MFH - Mobile, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą
Instrukcje Airconditioner Airwell
4 Lipca 2024
4 Lipca 2024
3 Lipca 2024
3 Lipca 2024
1 Lipca 2024
1 Lipca 2024
1 Lipca 2024
30 Czerwca 2024
28 Czerwca 2024
28 Czerwca 2024
Instrukcje Airconditioner
- Airconditioner Bauknecht
- Airconditioner Samsung
- Airconditioner Electrolux
- Airconditioner LG
- Airconditioner Dometic
- Airconditioner Whirlpool
- Airconditioner Fujitsu
- Airconditioner Panasonic
- Airconditioner Toshiba
- Airconditioner Einhell
- Airconditioner Haier
- Airconditioner Honeywell
- Airconditioner Daikin
- Airconditioner Alaska
- Airconditioner OneConcept
- Airconditioner Trotec
- Airconditioner AKAI
- Airconditioner Aermec
- Airconditioner Kenmore
- Airconditioner Galanz
- Airconditioner Daewoo
- Airconditioner Zibro
- Airconditioner Eurom
- Airconditioner Airlux
- Airconditioner Acson
- Airconditioner Amcor
- Airconditioner Andrews
- Airconditioner Akira
- Airconditioner Aircooler
- Airconditioner Argo
- Airconditioner Ariston
- Airconditioner Aertesi
- Airconditioner Tosot
- Airconditioner Termozeta
- Airconditioner Inventor
- Airconditioner Olimpia Splendid
- Airconditioner Duux
- Airconditioner Maiko
- Airconditioner Aircool
- Airconditioner MundoClima
- Airconditioner Telair
- Airconditioner MDV
- Airconditioner Mobile Airco
- Airconditioner Qlima - Zibro
- Airconditioner Bryant
- Airconditioner Klima1stKlaas
- Airconditioner Shinco
- Airconditioner Innova
Najnowsze instrukcje dla Airconditioner
19 Września 2024
19 Września 2024
17 Września 2024
17 Września 2024
11 Września 2024
9 Września 2024
8 Września 2024
8 Września 2024
7 Września 2024
5 Września 2024