3M™ No Polish SC Connector SM and MM
250/900 µm
Instructions
3
November 2010
78-8140-0034-1-E
2
Contents
1.0 KitContents............................................................................................................................................................................... 3
2.0 3M™NoPolishSCConnectorSMandMM250/900µm........................................................................................................ 3
3.0 3M™NoPolishConnector(NPC)Re-termination...............................................................................................................7
4.0 LossTesting............................................................................................................................................................................... 8
Safety Precautions
Protective Eyewear
c CAUTION
Safetyglassesshouldbewornwhenhandlingchemicalsandcleavingtheopticalber.
Chemical Precautions
c WARNING
Storage,useanddisposalofisopropylalcoholshouldbeperyourcompanyhealth,safetyandenvironmentalinstructions.Referto
MaterialSafetyDataSheetforhealthhazards,safehandling,properuseandcontrolmeasures.
c CAUTION
Productcontainsphenylmethylsilicone(63148-58-3),hydrophobicsilica(68611-44-9)andmaycauseminimaleyeirritation.Avoid
contactwitheyesandwashhandsbeforeeatingorsmoking.Uponeyecontact,immediatelyusheyeswithwaterwhileholdingeyelids
openandcontinueushingfortenminutes.Contactaphysician.Uponskincontact,washwithsoapandwater.ProductInformation:
MaterialSafetyDataSheetor3MCompany,St.PaulMN,55144-1000,(651)733-1110Operator55
Bare Fiber Handling
c CAUTION
Cleavedglassbersaresharpandcanpiercetheskin.Usetweezerswhenhandlingshardsanddisposeofthemproperlyperyourcom-
panyhealthandsafetyinstructions.
Fiber/Cable Handling
c CAUTION
Opticalbercanbedamagedbyexcessivetensile,compressiveandbendingforces.Consultthemanufactures'specicationsforproper
handlinginstructions.
Laser Safety
c CAUTION
Taketheproperprecautionswhenworkingwithopticalberbecauseinvisiblelaserlightmaybepresent.Theprincipallaserhazardwhen
workingwithberopticsisinjurytotheeye.Neverlookdirectlyintotheberorconnectorusingthenakedeyeoramicroscope.
3
1.0 Kit Contents
1.1 Thediagramsbelowshowthepartsofthe3M™No
PolishConnector(singlemodepictured)andthe3M
™
NoPolishConnectorAssemblyTool8865-AT.Please
reviewthesedrawingstounderstandtheinstructionsin
thefollowingpages.
3M
™
No Polish SC Connector
Fiber
Ferrule
Splice
Element
Buffer
Clamp
Boot
Spring
< 50 mm ( )2”
Length
Shell
Collar
Backbone
3M™ No Polish Connector Assembly Tool 8865-AT
SC coupling
Element actuator button
Drag finger
Release lever
Actuation Tool
Assembly Base
Guide Funnel
Fiber Clamp
Fiber Covers
Fiber Holder
Fiber Holder
2.0 3M™ No Polish SC Connector SM
and MM 250/900 µm
2.1 Removethedustcapsfromthefrontandrearofthe
connector.Opentheactuatorbuttonontheassemblytool.
Inserttheconnectorwiththewhiteactuationcapfacing
upintothecoupling,pushingforwarduntilitclicks.
2.2 Cleantheberholderwithalint-freeclothsoaked
withalcohol.Moveguidefunnelforwardonber
holderuntilitstops;openbercoversandber
clamp.
Specyfikacje produktu
Marka: | 3M |
Kategoria: | Tang |
Model: | 8865 |
Potrzebujesz pomocy?
Jeśli potrzebujesz pomocy z 3M 8865, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą
Instrukcje Tang 3M
16 Sierpnia 2024
Instrukcje Tang
Najnowsze instrukcje dla Tang
3 Października 2024
3 Października 2024
26 Września 2024
4 Września 2024
3 Września 2024
1 Września 2024
1 Września 2024
31 Sierpnia 2024
28 Sierpnia 2024
24 Sierpnia 2024