Strona 1/22
Eikon
20453-20457
Arké
19453-19457
Idea
16923-16927
Plana
14453-14457
Transponder card readers
Installer manual
Index
TRANSPONDER CARD READERS from page 5
COMMUNICATION OBJECTS from page 5
FAQ from page 20
COMMUNICATION OBJECTS TRANSPONDER CARD READERSFAQ
4
For all the details about the Well-contact Plus system, refer to the installer manual that can be downloaded from
the Download Software Well-contact Plus section on the website www.vimar.com. 
5
Transponder card readers
TRANSPONDER CARD READERS
Transponder card readers
Transponder card readers
20457, 19457, 16927, 14457
Transponder card reader for installation outside rooms, KNX
standard, 2 relay outputs NO 4 A 24 V~, 2 inputs, power supply
12-24 V~ 50-60 Hz and 12-24 V d.c. (SELV) - 3 modules.
Supplied without transponder card.
20453, 19453, 16923, 14453
Transponder card reader with vertical pocket for installation
inside rooms, KNX standard, 2 relay outputs NO 4 A 24 V~, 2
inputs, supplementary power supply 12-24 V~ 50-60 Hz and
12-24 V d.c. (SELV) - 3 modules.
Functionality
The device controls room access and various additional
functions. It also has 2 outputs and 2 inputs. The following
functions are the same for both channels.
3 functions are available for the outputs:
Not Active
Channel without any function.
Switch
The output is switched according to the other parameters.
Staircase
According to the other parameters, the output is switched for
a certain period of time.
3 functions are also available for the inputs:
Not Active
Channel without any function.
Grouped channels
Dimmer or shutter function.
Single channels
Switch, counter, scene, short/long switch function. Single key
dimming, Single key shutter.
Behaviour after bus on/off
Bus off: depends on the parameter settings.
Bus on: depends on the parameter settings.
Behaviour after reset
As for bus on.
Behaviour after power supply on/off
Off: the relays return to Off.
On: as for bus on.
Communication objects
List of existing communication objects (output)
20457 20453
6
Transponder card readers
Communication objects
These objects exist only once.
General communication objects
Output communication objects (example: Output A - Switch, Output B - Staircase)
Input communication objects (example: Input A - 8-bit value counter, Input B - single key dimming)
7
COMMUNICATION OBJECTS
Transponder card readers
Communication objects
Continues
Channel communication objects (if a channel is inactive, no communication objects are present)
No. ETS name Function Description Function details length Flag 1
C R W T U
0 Transito Transito reader +
pocket
a byte with the access card data is sent with each
pass of a valid card: this object must be associated
with a dedicated group for each device in each room
to enable Well-Contact Suite to compile the list of
accesses
4 byte X X X
1 Transit&Purse Transit + electronic purse reader +
pocket
a byte with the access card data (including monetary
software data) with each pass of a valid card 8 byte X X X
2 CO_accessType1 Access Guest Access reader +
pocket
this bit is set to 1 when a valid card with a Guest
(room customer) profile is recognised 1 bit X X X
3 CO_accessType2 Access Service Staff reader +
pocket
this bit is set to 1 when a valid card with a Service
(cleaning staff) profile is recognised 1 bit X X X
4 CO_accessType3 Access Maintenance reader +
pocket
this bit is set to 1 when a valid card with a Mainte-
nance (facility maintenance staff) profile is recognised 1 bit X X X
5 CO_accessType4 Access Installer reader +
pocket
this bit is set to 1 when a valid card with an Installer
(system installer) profile is recognised 1 bit X X X
6 CO_accessType5 Access Security Staff reader +
pocket
this bit is set to 1 when a valid card with a Security
(facility security staff) profile is recognised 1 bit X X X
7 CO_accessType6 Access Assistance reader +
pocket
this bit is set to 1 when a valid card with a Assis-
tance (facility assistance staff) profile is recognised 1 bit X X X
8 CO_accessType7 Access Administration reader +
pocket
this bit is set to 1 when a valid card with the Admin-
istration (facility director) profile is recognised 1 bit X X X
9CO_Scen
Control Scene control reader +
pocket
(if the "Scene number for access XY" parameters are
activated for the various Guest, Service profiles, etc.
and a scene number to be activated is associated
for the desired profiles) if access with a valid card
with a profile enabled for activation of a scene 1..64,
when the card is passed the value of the associated
scene in the parameters to that profile will be sent
1 byte X X X
10 CO_Energy Energy pocket on recognising a valid card this object commands
the room's ENERGY FM relay 1 bit X X X
11 CO_Light Light pocket on recognising a valid card this object commands
the room's GENERAL LIGHT relay 1 bit X X X
12 CO_validAccess Valid access reader
on recognising a valid card, this object goes to 1 to
activate the electrical lock relay (step relay that can
be automatically deactivated by this reader object af-
ter a time that can be set in the reader's parameters)
1 bit X X X
13 CO_courtesyLight Courtesy Light reader
on recognising a valid card, this object goes to 1 to
activate the electrical lock relay (step relay that can
be automatically deactivated by this reader object af-
ter a time that can be set in the reader's parameters)
1 bit X X X
14 CO_alarm1 Alarm 1 reader +
pocket
alarm objects inside the device (after a power failure
the internal clock must be resynchronised) 1 bit X X X
15 CO_alarm2 Alarm 2 reader +
pocket
alarm objects inside the device ("device fault" alarm,
e.g. after a CRC-ERROR) 1 bit X X X
16 CO_alarm3 Alarm 3 reader +
pocket
alarm objects inside the device (full list of 250 transits
without transit overwriting activated) 1 bit X X X
17 CO_clock Clock reader +
pocket
object needed by Well-Contact Suite to synchronise
the system devices 8 bytes X X X X
18 CO_time Time reader +
pocket
object needed by Well-Contact Suite to synchronise
the system devices 3 byte X X X X
19 CO_date Date reader +
pocket
object needed by Well-Contact Suite to synchronise
the system devices 3 byte X X X X
20 CO_serverConfirm Server Confirm reader +
pocket
object needed by Well-Contact Suite to make the
device wait for an Acknowledge response from the
reception PC after receiving the sent access data
4 byte X X X X
21 CO_plantID Plant number reader +
pocket
object dedicated to system divertification with
Well-Contact Suite software 4 byte X X X
C R W T = Communication; = Read; = Write; = Transmission; = Enable updateU
8
Transponder card readers
Communication objects
No. ETS name Function Description Function details length Flag 1
C R W T U
22 CO_accessData Access data reader +
pocket
object dedicated to system divertification with
Well-Contact Suite software 10 byte X X X X
23 CO_disableAc-
cessType1
Disable Access Guest
Access
reader +
pocket
if this object is activated the device will deny access
to the Guest card profile 1 bit X X X
24 CO_disableAc-
cessType2
Disable Access Service
Access Staff
reader +
pocket
if this object is activated the device will deny access
to the Service card profile 1 bit X X X
25 CO_disableAc-
cessType3 Disable Access Maintenance reader +
pocket
if this object is activated the device will deny access
to the Service Engineer card profile 1 bit X X X
26 CO_disableAc-
cessType4 Disable Access Installer reader +
pocket
if this object is activated the device will deny access
to the Installer card profile 1 bit X X X
27 CO_disableAc-
cessType5 Disable Access Security Staff reader +
pocket
if this object is activated the device will deny access
to the Security card profile 1 bit X X X
28 CO_disableAc-
cessType6 Disable Access Assistance reader +
pocket
if this object is activated the device will deny access
to the Assistance card profile 1 bit X X X
29 CO_disableAc-
cessType7
Disable Access Adminis-
tration
reader +
pocket
if this object is activated the device will deny access
to the Administration card profile 1 bit X X X
30 CO_led On1 LED 1 On reader LED 1 On (controls on/off of 2nd LED generally used
for "do not disturb" or "room occupied") 1 bit X X X
31 CO_ledBlink1 LED 1 fast blink reader LED 1 Fast blink 1 bit X X X
32 CO_led On2 LED 2 On reader LED 2 On (controls on/off of 3rd LED generally used
for "room service call") 1 bit X X X
33 CO_ledBlink2 LED 2 Fast blink reader LED 2 Fast blink 1 bit X X X
34 CO_led On3 LED 3 On reader LED 3 On (controls on/off of 4th LED generally used
for "make up room") 1 bit X X X
35 CO_ledBlink3 LED 3 Fast blink reader LED 3 Fast blink 1 bit X X X
36 CO_sound Sound 1 reader +
pocket
single sound (sound can be associated with a 1-bit
object on the bus) 1 bit X X X
37 CO_repeatedSound Repeated sound 1 reader +
pocket
repeated sound (repeated sound can be associated
with a 1-bit object on the bus and can be reset with
0 bit)
1 bit X X X
38 CO_Reset Reset Alarm reader +
pocket
object used to reset the internal alarms (objects nos.
14,15,16 ) 1 bit X X X
39 Not used
40 CO_CardInserted Card Inserted pocket
Simulates the insertion of a generic valid card (to
simulate the presence of staff in the room from the
supervision page)
1 bit X X x
41 Output 1 Switch on/off reader +
pocket to switch On/Off relay output (if set as "Switch") 1 bit X X
42 Output 1 Staircase reader +
pocket
to set relay output to automatically deactivate after
the time set in the device parameters (if set as "Stair
Light")
1 bit X X
43 Output 1 Block reader +
pocket
to block command of relay output via the bus (if set
as "Switch" and the "Block" function is activated) 1 bit X X
44 Output 1 Forced reader +
pocket
to force the relay output via bus (if set as "Switch"
and the "Forcing" function is activated) 2 bit X X
45 Output 1 Scene reader +
pocket
to activate a scene on the relay output (if set as
"Switch" and the Scene function is activated); it is
also possible to save the scene if the corresponding
function is activated in the bus parameters
1 byte X X
46 Output 1 Status reader +
pocket
to determine the On/Off status of the relay output (if
set as "Switch" or as "Staircase") 1 bit X X X
47 Output 1 Logic 1 reader +
pocket
(if set as "Switch" and the "One-object/Two-objects
logic" is activated): if a 1 bit is sent to this object the
output will be activated when the "on/off" and op-
tional "Logic-2" objects are also activated (depend-
ing on the AND/OR conditions that are managed on
these objects)
1 bit X X
48 Output 1 Logic 2 reader +
pocket
(if set as "Switch" and the " One-object/Two-objects
logic" is activated): if a 1 bit is sent to this object
the output will be activated when the "on/off" and
"Logic-2" objects are also activated (depending on
the AND/OR conditions that are managed on these
objects)
1 bit X X
Continued
Continues C R W T = Communication; = Read; = Write; = Transmission; = Enable updateU
9
COMMUNICATION OBJECTS
Transponder card readers
Communication objects
No. ETS name Function Description Function details length Flag 1
C R W T U
49 Output 2 Switch on/off reader +
pocket to switch relay output On/Off (if set as "Switch") 1 bit X X
50 Output 2 Staircase reader +
pocket
to set the relay output to automatically deactivate
after the time set in the device parameters (if set as
"Staircase")
1 bit X X
51 Output 2 Block reader +
pocket
to block command of relay output via the bus (if set
as "Switch" and the "Block" function is activated) 1 bit X X
52 Output 2 Forced reader +
pocket
to force the relay output via bus (if set as "Switch"
and the "Forcing" function is activated) 2 bit X X
45 Output 2 Scene reader +
pocket
to activate a scene on the relay output (if set as
"Switch" and the "Scene" function is activated); it is
also possible to save the scene if the corresponding
function is activated in the bus parameters
1 byte X X
54 Output 2 Status reader +
pocket
to determine the On/Off status of the relay output (if
set as "Switch" or as "Staircase") 1 bit X X X
55 Output 2 Logic 1 reader +
pocket
to activate the Logic on the relay output (if set as
"Switch" and the "One-object/Two-objects logic"
function is activated)
1 bit X X
48 Output 2 Logic 2 reader +
pocket
to activate the Logic on the relay output (if set as
"Switch" and the "Two-objects logic" function is
activated)
1 bit X X
57 Input 1 Switch reader +
pocket
if the device is set to "single inputs" - for On/Off
command from a contact connected to the input
(if set as "Switch", with "Switch rising/falling edge"
or "Toggle rising/falling edge" or "Send Status"
functions)
1 bit X X X
57 Input 1 Send value reader +
pocket
if the device is set to "single inputs" - to send a
numerical value 0-255 to the bus on activation of the
input (if set as "Switch", with "Send Value" function
"Number" type)
1 byte X X X
57 Input 1 Send value reader +
pocket
if the device is set to "single inputs" - to send a nu-
merical value 0-65535 to the bus on activation of the
input (if set as "Switch", with "Send Value" function
"Float" type)
2 byte X X X
57 Input 1 Counter reset reader +
pocket
if the device is set to "single inputs" - to reset the
value of the counter (if set as "Counter") 1 bit X X X
57 Input 1 Button reader +
pocket
if the device is set to "single inputs" - to send an
ON or OFF for short and long activation of the input
contact, depending on the possible selections in
the parameters (if set as "Switch short/long" with
"Switch" type)
1 bit X X X
57 Input 1 Send value reader +
pocket
if the device is set to "single inputs" - to send two
different 1-byte values for short and long activation
of the input contact, depending on the possible
selections in the parameters (if set as " Switch short/
long" with "Number" type)
1 byte X X X
57 Input 1 Send value reader +
pocket
if the device is set to "single inputs" - to send two
different 2-byte values for short and long activation
of the input contact, depending on the possible
selections in the parameters (if set as " Switch short/
long" with "Float" type)
2 byte X X X
57 Input 1 Dimming On/Off reader +
pocket
if the device is set to "single inputs" - to perform
On/Off of a dimmable light (if set as "One button
dimming")
1 bit X X X
57 Input 1 Shutter reader +
pocket
if the device is set to "single inputs" - for operation
of the shutter by long activation of the input (if set
as "One-button shutter control"), it does not control
the blinds
1 bit X X X
57 Input 1/2 Dimming On/Off reader +
pocket
if the device is set to "grouped inputs" - to perform
On/Off of a dimmable light by means of short activa-
tion of one input or another (if set as "dimming")
1 bit X X X
57 Input 1/2 Sun protection reader +
pocket
if the device is set to "grouped inputs" - for operation
of the shutter by means of activation of one input or
another (if set as "shutter control")
1 bit X X X
Continued
Continues C R W T = Communication; = Read; = Write; = Transmission; = Enable updateU
11
COMMUNICATION OBJECTS
Transponder card readers
Communication objects
No. ETS name Function Description Function details length Flag 1
C R W T U
62 Input 2 Send value reader +
pocket
if the device is set to "single inputs" - to send a nu-
merical value 0-65535 to the bus on activation of the
input (if set as "Switch", with "Send Value" function
"Float" type)
2 byte X X X
62 Input 2 Counter reset reader +
pocket
if the device is set to "single inputs" - to reset the
value of the counter (if set as "Counter") 1 bit X X X
62 Input 2 Button reader +
pocket
if the device is set to "single inputs" - to send an
ON or OFF for short and long activation of the input
contact, depending on the possible selections in the
parameters (if set as "Switch short/long" press with
"Switch" type)
1 bit X X X
62 Input 2 Send value reader +
pocket
if the device is set to "single inputs" - to send two
different 1-byte values for short and long activation
of the input contact, depending on the possible
selections in the parameters (if set as "Switch short/
long" press with "Number" type)
1 byte X X X
62 Input 2 Send value reader +
pocket
if the device is set to "single inputs" - to send two
different 2-byte values for short and long activation
of the input contact, depending on the possible
selections in the parameters (if set as "Switch short/
long" press with "Float" type)
2 byte X X X
62 Input 2 Dimming On/Off reader +
pocket
if the device is set to "single inputs" - to perform
On/Off of a dimmable light (if set as "One button
dimming")
1 bit X X X
62 Input 2 Shutter reader +
pocket
if the device is set to "single inputs" - for operation
of the shutter by long activation of the input (if set as
"One-button shutter"), it does not control the blinds
1 bit X X X
63 Input 2 Counter Threshold reader +
pocket
if the device is set to "single inputs" - to activate
the counter threshold (if set as "Counter" and the
"Threshold" parameter is activated with a desired
value)
1 byte X X X X
63 Input 2 Dimming reader +
pocket
if the device is set to "single inputs" - to dim a light (if
set as "single key dimming") 4 bit X X X
63 Input 2 Shutter Stop reader +
pocket
if the device is set to "single inputs" - to stop the
shutter (if set as "1-button shutter control") with short
activation of the input
1 bit X X X
64 Input 2 Scene reader +
pocket
if the device is set to "single inputs" - to send a
scene call-up on activation of the input (if set as
"Scene" with the desired numerical value): it is also
possible a prolonged 2 sec. activation of the input
sends a scene-save message to the bus, if the
parameter with "Save" function is enabled
1 byte X X X
64 Input 2 1-Bit Scene reader +
pocket
to send a 1-bit scene call-up on activation of the
input (if set as "1-bit type scene): useful for old KNX
devices that operate with 1-bit scenes
1 bit X X X
65 Input 2 Counter reader +
pocket
if the device is set to "single inputs" - 8-bit value of
counter that increases with the input contact pulse
count according to the count settings and the bus
message send settings in the Parameters (if set as
"Counter" with "8 bit" type)
1 byte X X X
65 Input 2 Counter reader +
pocket
if the device is set to "single inputs" - 16-bit value of
counter that increases with the input contact pulse
count according to the count settings and the bus
message send settings in the Parameters (if set as
"Counter" with "16 bit" type)
2 byte X X X
65 Input 2 Counter reader +
pocket
if the device is set to "single inputs" - 32-bit value of
counter that increases with the input contact pulse
count according to the count settings and the bus
message send settings in the Parameters (if set as
"Counter" with "32 bit" type)
4 byte X X X
Continued
Continues C R W T = Communication; = Read; = Write; = Transmission; = Enable updateU
12
Transponder card readers
Communication objects
No. ETS name Function Description Function details length Flag 1
C R W T U
65 Input 2 Status reader +
pocket
if the device is set to "single inputs" - to deter-
mine the input On/Off status (if set as "single key
dimming")
1 bit X X X X
66 Input 2 Blocking object reader +
pocket
if the device is set to "single inputs" - to block
sending of bus commands from the bus for the input
regardless of the switching status of the connected
contact, if the "Block" parameter is activated on the
input
1 bit X X X
67 Central Switch
function ON/OFF reader +
pocket
(for simultaneous control of two outputs, if the cor-
responding parameters are activated on the device
outputs)
1 bit X X
Continued
C R W T = Communication; = Read; = Write; = Transmission; = Enable updateU
ETS text Available values Comment
[Default value]
Key A Upper [2 byte] 0-65535
Parameters on card
cells for
MyFare protocol
(for monetary systems)
[65535]
Key A Mid [2 byte] 0-65535
[65535]
Key A Lower [2 byte] 0-65535
[65535]
Key A Upper [2 byte] 0-65535
[65535]
Key A Mid [2 byte] 0-65535
[65535]
Key A Lower [2 byte] 0-65535
[65535]
CCP Upper [2 byte] 0-65535
[65535]
CCP Lower [2 byte] 0-65535
[65535]
Advanced Menu
0 Disable If enabled, a new
parameter section
appears with various
values to be set for in-
terfacing with monetary
software (as in notes
below)
1 Enable
[0]
ETS Reference parameters
Card data and software configuration
Card Info
Card info
Distinguish diversify devices from different systems interfacing
with monetary software.
13
COMMUNICATION OBJECTS
Transponder card readers
Communication objects
ETS text Available values Comment
[Default value]
Block Size 0-65535
Parameters on card
cells for MyFare pro-
tocol (for monetary
systems)
[16]
Total Block Numbers 0-65535
[63]
Base Address Block 0-65535
[4]
Block AUX1 address 0-65535
[5]
Block AUX2 address 0-65535
[6]
Block Keys
address + CCP
0-65535
[7]
Key B Upper [2 byte] 0-65535
[65535]
Key B Mid [2 byte] 0-65535
[65535]
Key B Lower [2 byte] 0-65535
[65535]
CCP Upper [2 byte] 0-65535
[65535]
CCP Lower [2 byte] 0-65535
[65535]
Block Base address 0-65535
[8]
Block AUX1 address 0-65535
[9]
Block AUX2 address 0-65535
[10]
Block Keys address
+ CCP
0-65535
[11]
Key B Upper [2 byte] 0-65535
[65535]
Key B Mid [2 byte] 0-65535
[65535]
Key B Lower [2 byte] 0-65535
[65535]
CCP Upper [2 byte] 0-65535
[143]
CCP Lower [2 byte] 0-65535
[30472]
Advanced Menu
Advanced Menu
If the parameter is enabled, an additional "Advanced Menu"
page for interfacing with monetary software is displayed.


Specyfikacje produktu

Marka: Vimar
Kategoria: Niesklasyfikowane
Model: 19457

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z Vimar 19457, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje Niesklasyfikowane Vimar

Instrukcje Niesklasyfikowane

Najnowsze instrukcje dla Niesklasyfikowane

SmallRig

SmallRig VB99 SE Instrukcja

29 Stycznia 2025
QSC

QSC TSC-8 Instrukcja

29 Stycznia 2025
XTRARM

XTRARM XTR-FS5130 Instrukcja

29 Stycznia 2025
Sunding

Sunding SD-581G Instrukcja

29 Stycznia 2025
XTRARM

XTRARM XTR-FS5070 Instrukcja

29 Stycznia 2025
XTRARM

XTRARM XTR-FS2010 Instrukcja

29 Stycznia 2025
OSEE

OSEE TX402 Instrukcja

29 Stycznia 2025