OPERATING MANUAL
WATER SEPARATOR
EN
TRT-BA-WA4I-HS-001-EN
WA 4i
A - 1 Operating manual – WA 4i water separator
EN
TABLE OF CONTENTS
01. General description . . . . . . . . . . . . . . . . A - 01
02. Read before start-up A - 01 . . . . . . . . . . . . . . .
03. Principle of operation A - 03 . . . . . . . . . . . . . .
04. Start-up ......................... A - 04
05. Shutdown ....................... A - 04
06. Care and maintenance A - 05 .............
07. Technical data WA 4 i A - 06 ..............
08. Faults and troubleshooting A - 06 ..........
09. Warranty ........................ A - 07
10. EC Declaration of Conformity A - 08 ........
This release replaces all previous releases. No part of this publication may be
reproduced without written permission. The same applies for electronically
processing, duplicating or spreading the publication. Subject to technical chang-
es. All rights reserved. Trademarks are used without guarantee that they may be
used freely and primarily following the spelling of the manufacturer. The product
names used are registered and should be treated appropriately. The right to make
construction changes in the interests of constant product improvement as well
as changes to the shape and colour is reserved. The scope of delivery may vary
from product images. This document was produced with all due care. We accept
no liability whatsoever for mistakes or omissions. © TROTEC
®
01. GENERAL DESCRIPTION
The water separator WA4i is a device for commercial
use that was designed for combined usage with the
Trotec insulation dryers VX5, the HEPA lter and the
NR silencers.
The insulation dryer and the water separator constitute
an operating unit. The water separator WA 4i enables
suction of both contaminated air containing water and
free water itself.
02. READ BEFORE START-UP
The WA 4i is to be used as a water
separator for insulation drying of
screeds or flat roofs. It must be
set up vertically with all castors
standing on flat ground. The device
must not be used as storage place
or footstep.
For storage, up to 3 WA 4i devices
may be stacked on top of one another. The WA 4i is
positioned inside the provided borders.
The WA 4i water separator's task is to keep water
and dirt particles away from the intake flow of
downstream side channel blower.
1
2)
3
4
5
6
1. Vacuum connectors
2. Inlet connectors
3. Socket for the
insulation drying unit
4. Power button
5. Status indicator/
residual water button
6. Waste water
connection
7. TTKwic
quick coupling
2
7
EN Operating manual – WA 4i water separator
A - 2
The WA 4i is to be used in combination with a Trotec
Insulation drying unit. The use of other insulation dry-
ing units may lead to an insufficient water separation
and can thus cause damage.
The WA 4i's function is the separation of solids and
water during low-pressure insulation drying. To
protect the insulation drying units, the WA 4i has
fine filters with a filtration efficiency of 99% at 2
μm installed (see g.4). If there is a risk posed by
micro fibres or other harmful particles, the air exiting
the WA4i must be additionally cleaned with suitable
filters.
When using a downstream HEPA filter from Trotec,
the particle filtration efficiency can be increased to
99.8% of all particles up to a size of 0.3µm.
When using a Trotec silencer (see fig.3), the noise
level of the entire combined installation can be
reduced by up to 17 dBA.
Do not use the device with a relative humidity of more
than 90% or in the rain.
Please take the utmost care to ensure that neither
water nor solids enter the downstream insulation
drying unit. This would lead to blocking of the turbine
and thus to the destruction of the device. Therefore
it is always necessary to install a suitable water
separator upstream of the insulation drying unit in
low-pressure operation (see fig.3).
To avoid harmful emissions, it is recommended to
use HEPA filters in addition to the fine filters for every
low-pressure application.
The HEPA filters must be installed professionally
between the water separator (OUT) and the insu-
lation drying unit. The filters shown in the example
(fig. 3) are consumables and must be exchanged and
properly disposed of when they are dirty or saturated
or after every application at the latest.
Filter mat
The filter mat serves to protect the pump in the
water separator from dirt particles.
• Insert the mat in a way that the pump
is entirely enclosed.
• Please clean the mat regularly.
• You can rinse the filter mat with water.
Blue filter mat
3)
Industrial
insulation dryer
HEPA filter
WA 4i water
separator
Drying control
unit DA
Silencer


Specyfikacje produktu

Marka: Trotec
Kategoria: Niesklasyfikowane
Model: WA 4i

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z Trotec WA 4i, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje Niesklasyfikowane Trotec

Trotec

Trotec FS200 Instrukcja

8 Października 2024
Trotec

Trotec BZ21M Instrukcja

4 Października 2024
Trotec

Trotec IC300 Instrukcja

29 Września 2024
Trotec

Trotec IC200 Instrukcja

29 Września 2024
Trotec

Trotec IR 1510 SC Instrukcja

29 Września 2024
Trotec

Trotec BO22 Instrukcja

27 Września 2024
Trotec

Trotec BZ29OS Instrukcja

26 Września 2024
Trotec

Trotec VE 4 Instrukcja

24 Września 2024
Trotec

Trotec TD120 Instrukcja

23 Września 2024
Trotec

Trotec BD6A Instrukcja

23 Września 2024

Instrukcje Niesklasyfikowane

Najnowsze instrukcje dla Niesklasyfikowane

Stihl

Stihl HT 70 Instrukcja

15 Października 2024
Ernesto

Ernesto H14270 Instrukcja

15 Października 2024
Uniden

Uniden BT MIC KIT Instrukcja

15 Października 2024
Vaude

Vaude Omnis Bike 26 Instrukcja

15 Października 2024
ART

ART ProChannel II Instrukcja

15 Października 2024
Aukey

Aukey DR02J Instrukcja

15 Października 2024
Master Lock

Master Lock 653EURD Instrukcja

15 Października 2024
Roland

Roland FR-18 Diatonic Instrukcja

15 Października 2024