Instrukcja obsługi Tripp Lite SmartPro SMART3000RMXL2U

Tripp Lite UPS SmartPro SMART3000RMXL2U

Przeczytaj poniżej 📖 instrukcję obsługi w języku polskim dla Tripp Lite SmartPro SMART3000RMXL2U (64 stron) w kategorii UPS. Ta instrukcja była pomocna dla 12 osób i została oceniona przez 2 użytkowników na średnio 4.5 gwiazdek

Strona 1/64
1
Owner’s Manual
1111 W. 35th Street, Chicago, IL 60609 USA • www.tripplite.com/support
Copyright © 2014 Tripp Lite. All rights reserved. SmartPro
® is a registered trademark of Tripp Lite.
Español 22
Français 43
SmartPro® 2U Rackmount
Intelligent, Line-Interactive UPS Systems
120V Sine Wave Output • 2200VA—3000VA Capacities
SMART2200RM2U
(Series Number: AGSM8207)
SMART2200RMXL2U
(Series Number: AGSM8208)
SMART2200RMXL2UP
(Series Number: AGSM7012)
SMART3000RM2U
(Series Number: AGSM8209)
SMART3000RMXL2U
(Series Number: AGSM7010)
SMART3000RM2UP
(Series Number: AGSM7499)
Not suitable for mobile applications.
SMART2600RM2U
(Series Number: AGSM7012)
14-03-028-93-3088.indb 1 3/20/2014 4:08:27 PM
2
Important Safety Instructions
SAVE THESE INSTRUCTIONS
This manual contains important instructions that should be followed during the installation,
operation and storage of this product. Failure to heed these warnings may affect the warranty.
UPS Location Warnings
• UsecautionwhenliftingtheUPS.BecauseoftheconsiderableweightofallrackmountUPS
systems, at least two people should assist in lifting and installing them.
• InstalltheUPSindoors,awayfromexcessmoistureorheat,dustordirectsunlight.
• Forbestperformance,theambienttemperatureneartheUPSshouldbebetween0°Cand40°C
(between32°Fand104°F).
• LeaveadequatespacearoundallsidesoftheUPSforproperventilation.Donotobstructitsvents
or fan openings.
• WhenmountingtheUPSsysteminatowerorientation,makesuretheLCDScreenpanelisatthe
topoftheUPS,notatthebottom.
• Donotmountunitwithitsfrontorrearpanelfacingdown(atanyangle).Mountinginthismanner
will seriously inhibit the unit’s internal cooling, eventually causing product damage not covered
under warranty.
UPS Connection Warnings
• TheUPScontainsitsownenergysource(battery).Theoutputterminalsmaybeliveevenwhen
theUPSisnotconnectedtoanACsupply.
• ConnecttheUPStoaproperlygroundedACpoweroutlet.DonotmodifytheUPS’spluginaway
thatwouldeliminatetheUPS’sconnectiontoground.Donotuseadaptersthateliminatethe
UPS’sconnectiontoground.
• DonotplugtheUPSintoitself;thiswilldamagetheUPSandvoidyourwarranty.
• IfyouareconnectingtheUPStoamotor-poweredACgenerator,thegeneratormustprovide
filtered,frequency-regulatedcomputer-gradeoutput.ConnectingtheUPStoageneratorwillvoid
itsUltimateLifetimeInsurance.
Equipment Connection Warnings
• Useofthisequipmentinlifesupportapplicationswherefailureofthisequipmentcanreasonably
beexpectedtocausethefailureofthelifesupportequipmentortosignificantlyaffectitssafety
oreffectivenessisnotrecommended.Donotusethisequipmentinthepresenceofaflammable
anestheticmixturewithair,oxygenornitrousoxide.
• DonotconnectsurgesuppressorsorextensioncordstotheoutputoftheUPS.Thismight
damagetheUPSandmayaffectthesurgesuppressorandUPSwarranties.
14-03-028-93-3088.indb 2 3/20/2014 4:08:27 PM
3
Battery Warnings
• Batteriescanpresentariskofelectricalshockandburnfromhighshort-circuitcurrent.Observe
properprecautions.Donotdisposeofthebatteriesinafire.DonotopentheUPSorbatteries.
Donotshortorbridgethebatteryterminalswithanyobject.UnplugandturnofftheUPSbefore
performingbatteryreplacement.Usetoolswithinsulatedhandles.Therearenouser-serviceable
partsinsidetheUPS.Batteryreplacementshouldbeperformedonlybyauthorizedservice
personnelusingthesamenumberandtypeofbatteries(SealedLead-Acid).Thebatteries
arerecyclable.Refertoyourlocalcodesfordisposalrequirementsorvisitwww.tripplite.com/
UPSbatteryrecyclingforrecyclinginformation.TrippLiteoffersacompletelineofUPSSystem
ReplacementBatteryCartridges(R.B.C.).VisitTrippLiteontheWebatwww.tripplite.com/support/
battery/index.cfmtolocatethespecificreplacementbatteryforyourUPS.TheRBCTypecan
alsobefoundonthelabelaffixedtotheBatteryRetentionPlate.
• Duringhot-swapbatteryreplacement,theUPSwillnotprovidebackuppowerintheeventofa
blackout or other power interruptions.
• DonotoperatetheUPSwithoutbatteries.
External Battery Connection Warnings
• Whenaddingexternalbatterypackstoselectmodelswithexternalbatterypackconnectors,
connectonlyTrippLite-recommendedbatterypacksofthecorrectvoltageandtype.Donot
connectordisconnectbatterypackswhentheUPSisoperatingonbatterypower.
Visitwww.tripplite.com/support/battery/index.cfmtolocatethesupportedbatterytype(s)for
yourUPS.
Important Safety Instructions
14-03-028-93-3088.indb 3 3/20/2014 4:08:27 PM


Specyfikacje produktu

Marka: Tripp Lite
Kategoria: UPS
Model: SmartPro SMART3000RMXL2U

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z Tripp Lite SmartPro SMART3000RMXL2U, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje UPS Tripp Lite

Instrukcje UPS

Najnowsze instrukcje dla UPS