Instrukcja obsługi Tripp Lite SmartPro SMART1500LCDT
Tripp Lite
UPS
SmartPro SMART1500LCDT
Przeczytaj poniżej 📖 instrukcję obsługi w języku polskim dla Tripp Lite SmartPro SMART1500LCDT (36 stron) w kategorii UPS. Ta instrukcja była pomocna dla 4 osób i została oceniona przez 2 użytkowników na średnio 4.5 gwiazdek
Strona 1/36

LCDT-Series UPS Systems
Models:
SMART1500LCDT, OMNI1500LCDT, SMART1300LCDT
(AG-0066, AG-0067, AG-0068)
Important Safety Instructions 2
Quick Installation 3
Basic Operation 4
UPS On/Off 4
LCD Display 5
Display UPS/Power Conditions 6
Enable/Disable Alarm 6
Self-Test 7
Error Messages 7
Features 8
Battery Replacement 9
Storage and Service 10
Warranty Registration 11
Español 13
Français 25
Owner’s Manual
Warranty
Registration
Register online today for a
chance to win a FREE Tripp Lite
product! www.tripplite.com/warranty
1111 W. 35th Street, Chicago, IL 60609 USA • www.tripplite.com/support
Copyright © 2012 Tripp Lite. All rights reserved. SmartPro
® is a registered trademark of Tripp Lite.
TEST MUTE
TEST MUTE
12-12-069-93-327C.indb 1 12/6/2012 9:28:34 AM

2
SAVE THESE INSTRUCTIONS
This manual contains instructions and warnings that should be followed during the installation, operation and
storage of this product. Failure to heed these warnings may affect the warranty.
UPS Location Warnings
• InstallyourUPSindoors,awayfromexcessmoistureorheat,conductivecontaminants,dustordirectsunlight.
• Forbestperformance,keeptheindoortemperaturebetween32ºFand104ºF(0ºCand40ºC).
• LeaveadequatespacearoundallsidesoftheUPSforproperventilation.
• OnlysettheUPSuprightonasturdyatsurface.Donotblockfansorventilationholes,asthiswillseriouslyinhibittheunit'sinternal
cooling and cause product damage not covered under warranty.
UPS Connection Warnings
• ConnectyourUPSdirectlytoaproperlygroundedACpoweroutlet.DonotplugtheUPSintoitself;thiswilldamagetheUPS.
• DonotmodifytheUPS’splug,anddonotuseanadapterthatwouldeliminatetheUPS’sgroundconnection.
• DonotuseextensioncordstoconnecttheUPStoanACoutlet.
• IftheUPSreceivespowerfromamotor-poweredACgenerator,thegeneratormustprovideclean,ltered,computer-gradeoutput.
• ThemainssocketoutletthatsuppliestheUPSshouldbeeasilyaccessibleandlocatedneartheUPS.
Equipment Connection Warnings
• Useofthisequipmentinlifesupportapplicationswherefailureofthisequipmentcanreasonablybeexpectedtocausethefailureof
thelifesupportequipmentortosignicantlyaffectitssafetyoreffectivenessisnotrecommended.Donotusethisequipmentinthe
presenceofaammableanestheticmixturewithair,oxygenornitrousoxide.
• DonotconnectsurgesuppressorsorextensioncordstotheoutputofyourUPS.ThismightdamagetheUPSandmayaffectthesurge
suppressor and UPS warranties.
• ConnecttheUPStoanoutletthatisadequatelyprotectedagainstexcesscurrents,shortcircuitsandearthfaultsaspartofthe
building installation.
Battery Warnings
• Batteriescanpresentariskofelectricalshockandburnfromhighshort-circuitcurrent.Observeproperprecautions.Thereareno
user-serviceablepartsinsidetheUPS.DonotopentheUPSexcepttoperformbatteryreplacement.Donotopenbatteries.Donot
short or bridge the battery terminals with any object. Unplug and turn off the UPS before performing battery replacement. Use tools
withinsulatedhandles.Batteryreplacementshouldbeperformedonlybyauthorizedservicepersonnelusingthesamenumberand
typeofbatteries(SealedLead-Acid).Donotdisposeofthebatteriesinare.Thebatteriesarerecyclable.Refertoyourlocalcodes
fordisposalrequirementsorintheUSAonlycall1-800-SAV-LEADor1-800-8-BATTERY(1-800-822-8837)orvisitwww.rbrc.com
forrecyclinginformation.TrippLiteoffersacompletelineofUPSSystemReplacementBatteryCartridges(R.B.C.).VisitTrippLiteon
theWebatwww.tripplite.com/support/battery/index.cfmtolocatethespecicreplacementbatteryforyourUPS.
Important Safety Instructions
12-12-069-93-327C.indb 2 12/6/2012 9:28:34 AM

3
STEP 1: Plug the UPS into a properly grounded outlet.
After plugging the UPS into a wall outlet, press and hold the POWER BUTTONforone
secondtoturnontheUPS(SeeBasicOperationSection).
Note: The UPS will not turn on automatically in the presence of live utility power.
STEP 2: Plug your equipment into the UPS.
There are two sets of outlets on the back of your UPS. Outlets marked SURGE PROTECTED
do not provide battery backup power during power outages. Connect common desktop
itemslikeprinters,scannersandotheraccessoriesnotrequiringbatterysupporttothese
outlets.
OutletsmarkedBATTERY/SURGEPROTECTED offer UPS battery backup support during
powerfailures.Connectyourvitalcomputerequipmentintotheseoutlets.
YourUPSisdesignedtosupportelectronicequipmentonly.YouwilloverloadtheUPSif
thetotalVAratingsforalltheequipmentconnectedtotheBATTERY/SURGEPROTECTED
outletsexceedtheUPSoutputcapacity.Tondyourequipment’sVAratings,lookontheir
nameplates.Ifthe equipment islistedin amps, multiplythe numberofamps by 120to
determineVA.Forexample:1amp×120=120VA.Ifyoususpectyouhaveoverloaded
the outlets, check the Load Percentage and Load Meter screens (See Display UPS/Power
ConditionsdescriptionsinBasicOperationSection).Ifyouarestillunsure,runaself-test
(SeeSelf-TestdescriptioninBasicOperationSection).
Optional Installation
AllmodelsincludeUSBcommunicationports,tel/DSL/Ethernet(NotcompatiblewithPoE
applications)surgeprotectionjacksandcoaxiallineprotectionjacks.Theseconnections
areoptional;theUPSwillworkproperlywithouttheseconnections.Seetheconnector's
descriptionintheBasicOperationsectionforconnectioninstructions.
IftheLINEPOWERicon doesnotilluminatewhentheUPSisturnedON,trythefollowing:
1. Make sure that the UPS is plugged into a live AC outlet.
2. Press and hold the POWER BUTTONforonesecondtoturnontheUPS.Abeepshould
sound when the UPS starts.
3. IftheUPSstilldoesnotstart,contactTrippLiteTechSupportforassistance.
Quick Installation
12-12-069-93-327C.indb 3 12/6/2012 9:28:35 AM
Specyfikacje produktu
Marka: | Tripp Lite |
Kategoria: | UPS |
Model: | SmartPro SMART1500LCDT |
Potrzebujesz pomocy?
Jeśli potrzebujesz pomocy z Tripp Lite SmartPro SMART1500LCDT, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą
Instrukcje UPS Tripp Lite

30 Grudnia 2025

9 Października 2024

9 Października 2024

9 Października 2024

4 Października 2024

1 Października 2024

29 Września 2024

29 Września 2024

16 Września 2024

15 Września 2024
Instrukcje UPS
- UPS Ikea
- UPS AEG
- UPS Lenovo
- UPS Voltcraft
- UPS LC-Power
- UPS Conceptronic
- UPS Siemens
- UPS APC
- UPS HP
- UPS Teltonika
- UPS Block
- UPS Gembird
- UPS V7
- UPS Dell
- UPS Digitus
- UPS Schneider
- UPS FSP
- UPS GYS
- UPS Online USV
- UPS LevelOne
- UPS Equip
- UPS Emerson
- UPS CyberPower
- UPS JUNG
- UPS Eaton
- UPS Adj
- UPS PowerWalker
- UPS Salicru
- UPS Energenie
- UPS Steren
- UPS East
- UPS Liebert
- UPS Avocent
- UPS Minute Man
- UPS Furman
- UPS Minuteman
- UPS Riello
- UPS Maruson
- UPS Phoenix Contact
- UPS Puls Dimension
- UPS Vanson
- UPS Approx
- UPS Altronix
- UPS Bxterra
- UPS Middle Atlantic
- UPS Atlantis Land
- UPS FSP/Fortron
Najnowsze instrukcje dla UPS

5 Marca 2025

5 Marca 2025

30 Stycznia 2025

30 Stycznia 2025

30 Stycznia 2025

15 Stycznia 2025

15 Stycznia 2025

14 Stycznia 2025

14 Stycznia 2025

14 Stycznia 2025