1
Owner’s Manual
NetCommander® IP
Cat5 KVM Switch
Model: B070-016-19-IP2
(Series Number: AG-00C3)
1111 W. 35th Street, Chicago, IL 60609 USA • www.tripplite.com/support
Copyright © 2017 Tripp Lite. All rights reserved. All trademarks are the property of their respective owners.
PROTECT YOUR INVESTMENT!
Register your product for quicker service and ultimate peace of mind.
You could also win an ISOBAR6ULTRA surge protector—a $100 value!
www.tripplite.com/warranty
2
Table of Contents
Legal Notice............................3
1. Product Overview. . . . . . . . . . . . . . . . . . . . . . 3
1.1 Features and Benefits . . . . . . . . . . . . . . . . . . . . . . . .3
1.2 Terminology
................................
4
1.3 Target Server Compatibility . . . . . . . . . . . . . . . . . . . .4
1.4 Client Computer Compatibility . . . . . . . . . . . . . . . . . .4
1.5 Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
1.6 System Components . . . . . . . . . . . . . . . . . . . . . . . . .5
1.7 The NetCommander IP Unit . . . . . . . . . . . . . . . . . . . .6
1.8 Rackmounting the NetCommander IP . . . . . . . . . . . .8
1.8.1 Standard Console KVM Switch Instructions 8. . . . . . . . . . .
1.8.2 2-Post Rack Console KVM Switch Instructions 8
. . . . . . . .
1.9 Connecting the System
.......................
8
1.10 Initial Settings (Default IP Address) . . . . . . . . . . . .8
2. Web Configuration Interface
.............
12
2.1 Logging Into the Web Configuration Interface. . . . . .12
2.2 Web Configuration Interface Layout . . . . . . . . . . . . .13
2.3 My Targets Section . . . . . . . . . . . . . . . . . . . . . . . . . .14
2.4 Configuration Section . . . . . . . . . . . . . . . . . . . . . . . .15
2.4.1 Firmware Upgrade 16
............................
2.4.2 Backup/Restore 18. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2.4.3 SSL Certicate 19
..............................
2.4.4 Device 20
....................................
2.4.5 Users 21.....................................
2.4.6 Switch Configuration 22
..........................
2.4.7 User Targets 24
................................
2.4.8 Power Devices 24. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2.4.9 Power Outlets 26
...............................
2.4.10 Serial Ports 27. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2.4.11 Security 27
..................................
2.4.12 Authentication 29. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2.4.13 Date & Time 33
...............................
2.5 Password Section . . . . . . . . . . . . . . . . . . . . . . . . . . .33
2.6 Events Section. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .34
3. Conducting a Remote Session. . . . . . . . . . . . 35
3.1 Starting a Remote Session . . . . . . . . . . . . . . . . . . . .35
3.2 Remote Session Toolbar . . . . . . . . . . . . . . . . . . . . . .36
3.2.1 Pin Toolbar 36
.................................
3.2.2 Session 36
...................................
3.2.3 Video 38.....................................
3.2.4 Power 39.....................................
3.2.5 Keys 40......................................
3.2.6 Mouse 42
....................................
3.2.7 Server/Serial 45. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.2.8 Full Screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
3.2.9 Logout 45
....................................
3.3 Shared Session
.............................
45
3.4 Exclusive Session . . . . . . . . . . . . . . . . . . . . . . . . . . .45
4. Local Console ........................46
4.1 Move Label (F1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . .46
4.2 Tuning (F5) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .46
4.3 Power Management . . . . . . . . . . . . . . . . . . . . . . . . . .47
4.4 (F2) Setting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .47
5. Serial Port Pinout . . . . . . . . . . . . . . . . . . . . . 50
6. Security Certificate Installation . . . . . . . . . . 50
7. Technical Specifications . . . . . . . . . . . . . . . . 56
8. Video Resolution and Refresh Rates . . . . . . . 56
9. Warranty and Product Registration . . . . . . . . 57
3
Legal Notice
This manual and the software described in it are furnished under license, and may be used or copied only in accordance with the terms
of such license. The content of this manual is provided for informational use only, and is subject to change without notice. It should not in
and of itself be construed as a commitment by Tripp Lite, which assumes no responsibility of liability for any errors or inaccuracies that may
appear in this book.
The software that accompanies this manual is licensed for use by the Licensee only, in strict accordance with the software license
agreement, which the Licensee should read carefully before commencing use of the software. Except as permitted by the license, no part
of this publication may be reproduced, stored in retrieval system, or transmitted in any form or by any means, electronic, mechanical,
recording, or otherwise, without the prior written permission of Tripp Lite.
1. Product Overview
1.1 Features and Benefits
Directly connect up to 16 computers/servers.
Up to 3 users (1 local, 2 remote) can simultaneously access the KVM.
• Up to 5 users can share a single remote session.
Multi-level account access: and account types.Administrator User
• Remote authentication support; RADIUS and LDAP/S.
• Supports both IPv4 and IPv6.
• PDU Control - Add IP PDUs as devices that can be controlled by the KVM. Assign individual ports on the KVM to a PDU port to power cycle
or power off/on the computer/server connected to that port.
BIOS level control to any server’s brand and model, regardless of the server condition and network connectivity. Covers the entire spectrum
of crash scenarios.
Compatible with Windows® and Linux® operating systems.
Connect computer/servers up to 100 ft. (30 m) away from the KVM using inexpensive Cat5e/6* cabling and B078-101-USB2,
B078-101-USB-1 and B078-101-PS2 SIUs.
Java-based application allows control of a target server via web browser from any location over a secured IP connection.
Features two 10/100 Mbps LAN ports, so that if one fails, the other takes over.
Supports the highest security standards for encryption (128-bit AES and HTTPS).
Virtual Media allows an .iso file located in a Shared folder of a SAMBA or NFS server to be mounted to a Target Server and accessed as if
it were directly stored on it.
Supports Virtual Media data transfer rates up to 12Mbps (B078-101-USB2 required). A B078-101-USB-1 can be used to provide Virtual
Media support, but only at speeds up to 1Mbps.
Event log records events that take place on the installation, such as logins, reboots, network settings changes, etc..
Features two RJ45 serial ports for connecting serial manageable devices, such as PDUs, firewalls, and routers.
Allows for system sent messages to SNMP server to notify of LAN failures.
Allows for the installation of a SSL certicate to ensure secure transactions between the Web servers and browsers.
Graphical OSD and toolbars provide convenient, user-friendly remote operation.
Text based OSD provides convenient, user-friendly local operation.
Supports video resolutions up to 1920 x 1080 @ 60Hz. (B070-console KVMs are limited to video resolutions up to 1366 x 768 at the
local console.)
Flash upgradeable firmware over the network.
* To ensure proper functionality, shielded Cat5e/6 cable must be used with the B078-101-USB2, and is recommended for all other SIUs for best performance.


Specyfikacje produktu

Marka: Tripp Lite
Kategoria: Niesklasyfikowane
Model: NetCommander B070-016-19-IP2
Kolor produktu: Biały
Wbudowany wyłącznik: Tak
Wbudowany wyświetlacz: Nie
Częstotliwość wejściowa AC: 50 - 60 Hz
Napięcie wejściowe AC: 100 - 240 V
Wysokość produktu: 165 mm
Szerokość produktu: 100 mm
Głębokość produktu: 225.5 mm
Waga produktu: 880 g
Certyfikat środowiskowy (zrównoważonego rozwoju): RoHS
Poziom hałasu: 18.2 dB
Wbudowane głośniki: Nie
Certyfikaty: EAC\nCCC\nRCM\nKC\nFCC\nCE\nBSMI
Port USB: Tak
Obsługiwane systemy operacyjne Windows: Tak
Zgodny z Mac: Tak
Obsługiwane systemy operacyjne Mac: Tak
Prędkość transferu danych przez Ethernet LAN: 10,100,1000 Mbit/s
Ilość portów Ethernet LAN (RJ-45): 1
Zakres temperatur (eksploatacja): 5 - 40 °C
Zakres wilgotności względnej: 5 - 95 %
Zarządzanie przez stronę www: Tak
Taktowanie procesora: 1.3 GHz
Typ procesora: Marvell Armada 385
Model procesora: 88F6820
Przewody: AC,LAN (RJ-45),Wieland
Przewodowa sieć LAN: Tak
Zintegrowany czytnik kart: Nie
Obsługiwany systemy operacyjne Linux: Tak
Szyfrowanie / bezpieczeństwo: HTTPS,SSH,SSL/TLS
Diody LED: Tak
Zakres temperatur (przechowywanie): -20 - 60 °C
Funkcja kopii zapasowej: Tak
Cechy kopii zapasowej: Cloud,iSCSI LUN
Model: NAS
Klasa urządzenia: Home i Home Office
Zainstalowane urządzenie pamięci masowej: Tak
Całkowita pojemność zainstalowanej pamięci: 12 TB
Ilość obsługiwanych rozmiarów dysków pamięci: 2
Rodzaje zainstalowanych dysków: HDD
Obsługiwane rodzaje dysków: HDD & SSD
Interfejs napędów pamięci masowej: SATA
Pojemność dysku: 6000 GB
Rozmiary napędów pamięci masowej: 2.5/3.5 "
Usługa RAID: Tak
Liczba rdzeni procesora: 2
Typ pamięci wewnętrznej: DDR3
Pamięć wewnętrzna: 0.512 GB
Ilość portów USB 3.2 Gen 1 (3.1 Gen 1) Typu-A: 2
Obudowa: Komputer stacjonarny
Rodzaj chłodzenia: Aktywne
Liczba wentylatorów: 1 went.
Zainstalowany system operacyjny: DiskStation Manager
Lokalizacja zasilania: Zewnętrzny
Moc zasilacza: 60 W
Ilość jednostek zasilania: 1
Adapter zewnętrznego zasilania: Tak
Poziomy raid: 0,1,JBOD
Port wyjścia S/PDIF: Nie
Protokoły zarządzające: SNMP
Funkcja Wake-On-LAN: Tak
Kensington Lock: Tak
Typ gniazda zamka kabla: Kensington
Przycisk reset: Tak
Certyfikat Digital Living Network Alliance (DLNA): Tak
Obsługiwane protokoły sieciowe: SMB, AFP, NFS, FTP, WebDAV, CalDAV, Telnet, SSH, SNMP
Lista kontrolna dostępu (ACL): Tak
Zdalnie sterowany: Tak
Obsługiwane systemy plików: FAT,NTFS,ext3,ext4
Technologia okablowania Copper Ethernet: 10BASE-T,100BASE-TX,1000BASE-T
Obsługiwane przeglądarki: Chrome, Firefox, Internet Explorer 10+, Safari 10
Wersja systemu operacyjnego: 6.1.5
Obsługa zasilania zapasowego (RPS): Nie
Liczba zainstalowanych dysków: 2
Średnica czaszy wentylatora: 92 mm
Zatoka hot-swap: Nie
Wbudowany dysk optyczny: Nie
Obsługa iSCSI: Tak
Wbudowany serwer iTunes: Tak
Wsparcie wielojęzyczne: Tak
Wbudowany serwer FTP: Tak
Folder udostępniający: 256
Rejestr systemowy: Tak
Online RAID migration: Tak
Online RAID expansion: Tak
FireWire 800: Nie

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z Tripp Lite NetCommander B070-016-19-IP2, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje Niesklasyfikowane Tripp Lite

Instrukcje Niesklasyfikowane

Najnowsze instrukcje dla Niesklasyfikowane

SmallRig

SmallRig VB99 SE Instrukcja

29 Stycznia 2025
QSC

QSC TSC-8 Instrukcja

29 Stycznia 2025
XTRARM

XTRARM XTR-FS5130 Instrukcja

29 Stycznia 2025
Sunding

Sunding SD-581G Instrukcja

29 Stycznia 2025
XTRARM

XTRARM XTR-FS5070 Instrukcja

29 Stycznia 2025
XTRARM

XTRARM XTR-FS2010 Instrukcja

29 Stycznia 2025
OSEE

OSEE TX402 Instrukcja

29 Stycznia 2025