Instrukcja obsługi Toshiba RAS-H10BKCV-M
Przeczytaj poniżej 📖 instrukcję obsługi w języku polskim dla Toshiba RAS-H10BKCV-M (8 stron) w kategorii Airco. Ta instrukcja była pomocna dla 4 osób i została oceniona przez 2 użytkowników na średnio 4.5 gwiazdek
Strona 1/8
OWNER’S MANUAL
AIR CONDITIONER (SPLIT TYPE)
For general public use
Indoor unit
RAS-H10, 13, 18BKCV-M
RAS-10, 13, 16, 18BKCV-IN
Outdoor unit
RAS-H10, 13, 18BACV-M
RAS-10, 13, 16, 18BACV-IN
ENGLISH
ESPAÑOL
FRANÇAIS
ENGLISH
BAHASA MALAYSIA
01_1118350205_EN.indd 1
01_1118350205_EN.indd 1
01_1118350205_EN.indd 1
01_1118350205_EN.indd 101_1118350205_EN.indd 1 2/17/2559 BE 17:21
2/17/2559 BE 17:21
2/17/2559 BE 17:21
2/17/2559 BE 17:212/17/2559 BE 17:21
4
5
"
!
1
2
7
8
#
3
9
6
1Press : Move the louver in
the desired vertical direction.
2Press : Swing the air
automatically and press again to
stop.
3For horizontal direction, adjust
manually.
Note:
● Do not move the louver manually by others.
● The louver may automation positioning by some operation mode.
● Display brightness can be adjusted, follow procedure on . "
AUTOMATIC OPERATION
5
To automatically select cooling or fan only operation
1. Press : Select A.
2. Press : Set the desired temperature.
3. Press : Select AUTO, LOW , LOW+ , MED ,
MED+ , or HIGH .
1. Press : Select Cool or Fan only .
2. Press : Set the desired temperature.
Cooling: Min. 17°C, Fan Only: No temperature indication
3. Press : Select AUTO, LOW , LOW+ , MED ,
MED+ , or HIGH .
DRY OPERATION
COOLING / FAN ONLY OPERATION
7
6
For dehumidi cation, a moderate cooling performance is controlled fi
automatically.
1. Press : Select Dry .
2. Press : Set the desired temperature.
Hi-POWER OPERATION
8
To automatically control room temperature and air ow for faster cooling fl
(except in DRY and FAN ONLY mode)
Press : Start and stop the operation.
1TIMER (White)
2OPERATION (White)
1Infrared signal emitter
2Start/Stop button
3Mode select button (MODE)
4Temperature button (TEMP)
5Fan speed button (FAN)
6Swing louver button (SWING)
7Set louver button (FIX)
8Off timer button (OFF)
9High power button (Hi-POWER)
!Economy button (ECO)
"Clear button (CLEAR)
#Check button (CHECK)
PRECAUTIONS FOR SAFETY
REMOTE CONTROL
4
INDOOR UNIT DISPLAY
1
PREPARATION BEFORE USE
2
AIRFLOW DIRECTION
3
Preparing Filters
1. Open the air inlet grille and remove the air lters.fi
2. Attach the lters. (see detail in the accessory sheet).fi
Loading Batteries (when use wireless operation.)
1. Remove the slide cover.
2. Insert 2 new batteries (AAA type) following the (+)
and (–) positions.
Remote Control Reset
1. Remove the batteries.
2. Press .
3. Insert the batteries.
DANGER
●
Do not install, repair, open or remove the cover. It may
expose you to dangerous voltages. Ask the dealer or the
specialist to do this.
●
Turning off the power supply will not prevent potential electric
shock.
●
The appliance shall be installed in accordance with national
wiring regulation.
●
Means for disconnection from the supply having a contact
separation of at least 3 mm in all poles must be incorporated
in the xed wiring.fi
WARNING
●
Do not expose your body directly to cool air for a long time.
●
Do not insert your nger or any article into the air inlet/outlet.fi
●
When an abnormality (burning smell, etc.) occurs, stop the
air conditioner and disconnect the power supply or turn off
the breaker.
●
This appliance is not intended for use by persons (including
children) with reduced physical, sensory or mental
capabilities, or lack of experience and knowledge, unless they
have been given supervision or instruction concerning use of
the appliance by a person responsible for their safety.
●
Children should be supervised to ensure that they do not play
with the appliance.
●
Do not use any refrigerant different from the one speci ed fi
for complement or replacement. Otherwise, abnormally high
pressure may be generated in the refrigeration cycle, which
may result in a failure or explosion of the product or an injury
to your body.
CAUTION
●
Do not wash the unit with water. It may cause an electric
shock.
●
Do not use this air conditioner for other purposes such as
preserving food, breeding animal, etc.
●
Do not step or put anything on the indoor/outdoor unit. It may
cause an injury or damage the unit.
●
Do not touch aluminium n because it may cause an injury.fi
●
Before cleaning the unit, turn off the main switch or the circuit
breaker.
●
When the unit won’t be used for a long time, turn off the main
switch or the circuit breaker.
●
It is recommended that maintenance be performed by a
specialist when the unit has been operated for a long time.
●
The manufacturer shall not assume any liability for the
damage caused by not observing the description of this
manual.
01_1118350205_EN.indd 2
01_1118350205_EN.indd 2
01_1118350205_EN.indd 2
01_1118350205_EN.indd 201_1118350205_EN.indd 2 2/17/2559 BE 17:21
2/17/2559 BE 17:21
2/17/2559 BE 17:21
2/17/2559 BE 17:212/17/2559 BE 17:21
21
ECO OPERATION
9
To automatically control room to save energy (except in DRY and FAN ONLY
mode)
Press : Start and stop the operation.
Note: Cooling operation; the set temperature will increase automatically 1
degree/hour for 2 hours (maximum 2 degrees increase).
TEMPORARY OPERATION
12
In case of the misplaced or discharged remote control
● Pressing the RESET button, the unit can start
or stop without using the remote control.
● Operation mode is set on AUTOMATIC
operation, preset temperature is 24°C and fan
operation is automatic speed.
Set the timer when the air conditioner is operating.
Setting the OFF timer
1Press for enter OFF timer setting.
2Press for select desired OFF timer. (0.5 - 12 hrs)
3Press for set OFF timer.
4Press again for cancel OFF timer.
TIMER OPERATION
10
AUTO RESTART OPERATION
DISPLAY LAMP BRIGHTNESS ADJUSTMENT
13
11
To automatically restart the air conditioner after the power failure (Power of
the unit must be on.)
Setting
1. Press and hold the RESET button on the indoor unit for 3 seconds to
set the operation. (3 beep sound and OPERATION lamp blink 5 time/
sec for 5 seconds)
2. Press and hold the RESET button on the indoor unit for 3 seconds to
cancel the operation. (3 beep sound but OPERATION lamp does not
blink)
• In case of ON timer or OFF timer are set, AUTO RESTART
OPERATION does not activate.
To decrease the display lamp brightness or turn it off.
1. Press and hold for 3 seconds until brightness level ( , ,
or ) is shown on remote control LCD then release the button.
2. Press Rise or
Decrease
to adjust brightness in 4 levels.
Remote control
LCD Operation display Brightness
Lamp illuminates full brightness.
100%
Lamp illuminates 50% brightness.
50%
Lamp illuminates 50% brightness and the operation lamp
is turned off.
50%
All lamps are turned off.
All turned off
● In the examples of and , the lamp illuminates for 5 seconds before
going off.
SELF CLEANING OPERATION
(COOL AND DRY OPERATION ONLY)
14
OPERATION AND PERFORMANCE
16
1. Three-minute protection feature: To prevent the unit from being
activated for 3 minutes when suddenly restarted or switched to ON.
2. Some minor cracking sound may occur when unit operating. This is
normal because the cracking sound may be caused by expansion/
contraction of plastic.
Air conditioner operating conditions
Temp.
Operation
Outdoor Temperature Room Temperature
Cooling –10°C ~ 46°C 21°C ~ 32°C
Dry –10°C ~ 46°C 17°C ~ 32°C
The unit does not operate. Cooling is abnormally low.
● The power main switch is
turned off.
● The circuit breaker is
activated to cut off the power
supply.
● Stoppage of electric current
● ON timer is set.
● The lters are blocked with dust.fi
● The temperature has been set
improperly.
● The windows or doors are opened.
● The air inlet or outlet of the outdoor
unit is blocked.
● The fan speed is too low.
● The operation mode is FAN or DRY.
TROUBLESHOOTING (CHECK POINT)
17
REMOTE CONTROL A-B SELECTION
18
To separate using of remote control for each indoor unit in case of 2 air
conditioner are installed nearly.
Remote Control B Setup.
1. Press RESET button on the indoor unit to turn the air conditioner ON.
2. Point the remote control at the indoor unit.
3. Push and hold button on the Remote Control by the tip of the
pencil. “00” will be shown on the display. (Picture )1
4. Press during pushing . “B” will show on the display
and “00” will disappear and the air conditioner will turn OFF. The
Remote Control B is memorized. (Picture )2
Note: 1. Repeat above step to reset Remote Control to be A.
2. Remote Control A has not “A” display.
3. Default setting of Remote Control from factory is A.
Firstly, turn off the circuit breaker.
Indoor Unit and Remote Control
● Clean the indoor unit and the remote control with a wet cloth when
needed.
● No benzine, thinner, polishing powder or chemically-treated duster.
Air ltersfi
Clean every 2 weeks.
1. Open the air inlet grille.
2. Remove the air lters.fi
3. Vacuum or wash and then dry them.
4. Reinstall the air lters and close the air inlet grille.fi
MAINTENANCE
15
To protect bad smell caused by the humidity in the indoor unit.
1. If the button is pressed once during “Cool” or “Dry” mode,
the fan will continue to run for other 30 minutes, then it will turn off
automatically. This will reduce the moisture in the indoor unit.
2. To stop the unit immediately, press the more 2 times
within 30 seconds.
MA
CS
EN
01_1118350205_EN.indd 3
01_1118350205_EN.indd 3
01_1118350205_EN.indd 3
01_1118350205_EN.indd 301_1118350205_EN.indd 3 2/17/2559 BE 17:21
2/17/2559 BE 17:21
2/17/2559 BE 17:21
2/17/2559 BE 17:212/17/2559 BE 17:21
Specyfikacje produktu
Marka: | Toshiba |
Kategoria: | Airco |
Model: | RAS-H10BKCV-M |
Potrzebujesz pomocy?
Jeśli potrzebujesz pomocy z Toshiba RAS-H10BKCV-M, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą
Instrukcje Airco Toshiba
1 Października 2024
1 Października 2024
13 Września 2024
17 Sierpnia 2024
14 Sierpnia 2024
9 Sierpnia 2024
6 Lipca 2024
6 Lipca 2024
4 Lipca 2024
Instrukcje Airco
- Airco Samsung
- Airco Electrolux
- Airco DeLonghi
- Airco AEG
- Airco Beko
- Airco LG
- Airco Gorenje
- Airco Sharp
- Airco TCL
- Airco Russell Hobbs
- Airco Livoo
- Airco Dometic
- Airco Bosch
- Airco Whirlpool
- Airco Fujitsu
- Airco Ferroli
- Airco Midea
- Airco Kärcher
- Airco Hisense
- Airco Infiniton
- Airco Panasonic
- Airco Nedis
- Airco Medion
- Airco Black & Decker
- Airco Adler
- Airco Rinnai
- Airco Domo
- Airco GE
- Airco Ardes
- Airco Taurus
- Airco Orbegozo
- Airco Blaupunkt
- Airco Vivax
- Airco Siemens
- Airco Danby
- Airco Einhell
- Airco Haier
- Airco Sigma
- Airco Jocel
- Airco Rowenta
- Airco Mesko
- Airco Master
- Airco Honeywell
- Airco Tripp Lite
- Airco Truma
- Airco Hotpoint
- Airco Friedrich
- Airco Ariston Thermo
- Airco Zelmer
- Airco Wilfa
- Airco Amana
- Airco Furrion
- Airco Bomann
- Airco Emerio
- Airco Daikin
- Airco Stirling
- Airco MPM
- Airco Philco
- Airco Zanussi
- Airco Ravanson
- Airco Trotec
- Airco Thomson
- Airco Klarstein
- Airco Manta
- Airco Vaillant
- Airco Bavaria
- Airco Waeco
- Airco Camry
- Airco NewAir
- Airco Qlima
- Airco GUTFELS
- Airco TriStar
- Airco Bartscher
- Airco Mitsubishi
- Airco Dimplex
- Airco Baxi
- Airco Arçelik
- Airco Lavorwash
- Airco Gree
- Airco DCG
- Airco Sanyo
- Airco Clatronic
- Airco Telefunken
- Airco SVAN
- Airco Carson
- Airco Innoliving
- Airco Argoclima
- Airco Comfee
- Airco Bonaire
- Airco Meaco
- Airco Kenmore
- Airco VOX
- Airco Orima
- Airco Aspes
- Airco Hitachi
- Airco SereneLife
- Airco Frigidaire
- Airco EcoFlow
- Airco RCA
- Airco Climadiff
- Airco Sencor
- Airco Fuave
- Airco Kalorik
- Airco Suntec
- Airco Carrier
- Airco Geist
- Airco Daewoo
- Airco Livington
- Airco Consul
- Airco Zibro
- Airco Becken
- Airco Guzzanti
- Airco Tectro
- Airco Eurom
- Airco Proline
- Airco Amcor
- Airco Argo
- Airco Tosot
- Airco Vestel
- Airco Itho
- Airco Mabe
- Airco Heinner
- Airco Jocca
- Airco White Knight
- Airco Evolar
- Airco Royal Sovereign
- Airco Malmbergs
- Airco Listo
- Airco Daitsu
- Airco Milectric
- Airco Olimpia Splendid
- Airco Godrej
- Airco Maiko
- Airco Equation
- Airco Edy
- Airco Maxicool
- Airco Dantherm
- Airco Carrefour Home
- Airco MundoClima
- Airco Proklima
- Airco Eco-De
- Airco Hokkaido
- Airco Tarrington House
- Airco Evapolar
- Airco Kogan
- Airco Braemar
- Airco Klimaire
- Airco General Electric
- Airco SPT
- Airco Starlyf
- Airco Fuji Electric
- Airco Kibernetik
- Airco Companion
- Airco Prem-i-air
- Airco Bodin
- Airco AFINTEK
- Airco Brivis
- Airco MRCOOL
- Airco B-Air
- Airco Avallon
- Airco Protector
- Airco KwiKool
- Airco Arctic King
- Airco Climachill
- Airco Riffel
Najnowsze instrukcje dla Airco
1 Października 2024
1 Października 2024
1 Października 2024
1 Października 2024
30 Września 2024
30 Września 2024
30 Września 2024
30 Września 2024
30 Września 2024
30 Września 2024