Instrukcja obsługi Thermaltake Pacific V-RX 5700

Thermaltake Hardwarekoeling Pacific V-RX 5700

Przeczytaj poniżej 📖 instrukcję obsługi w języku polskim dla Thermaltake Pacific V-RX 5700 (2 stron) w kategorii Hardwarekoeling. Ta instrukcja była pomocna dla 4 osób i została oceniona przez 2 użytkowników na średnio 4.5 gwiazdek

Strona 1/2
Pacific V-RX 5700 Series Plus
VGA Water Block
Patented
16.8 Million Color
A x 1 B x 1 C D E F H I x 17 x 5 x 11 x 6 x 6 x 2G x 1
3
Remove the screws circled on the diagram.
Remove the screws circled on the diagram.
Remove the backplate (Remove the screws circled
on the diagram. All heat sink assembly screws
should be removed).
Use AMD RX 5700XT as a demonstration,
other model reference the installation guide.
When installing the water block, carefully position the water block with the preinstalled standoffs
on the graphics card.
Remove the power connector(Carefully detach the original stock cooler)
Cut the thermal pads to the dimensions listed and place them on the spots shown on the diagram.
Parts List
9
Apply thermal compound
Clean the original thermal compound
off the GPU die
Finish
2
1
87
G
This product is intended for installation only by expert users. Please consult with a qualified technician for installation. Improper installation may result in damage to your equipment.
Before you start using this product please follow these basic guidelines:
1. Please carefully read through the instruction manual before beginning the installation process.
2. Please remove your graphics card from your motherboard to insure the safest process and in order to prevent any possible damages to your CPU and motherboard.
3. It is strongly recommended to use market proven pre-mix coolant, such as Thermaltake Coolant 1000.
H
40 mm
54 mm
78 mm
78 mm
54 mm
9mm
7mm
F
C
E
D
CB
I
B
A
CD B
B
AB
C
D
5
46
10
Pacific V-RX 5700 Series Plus
VGA Water Block
Patented
16.8 Million Color
Parts List
Installation Guide
11
13
14
15 16
12
J
N
Connect the Waterblock onto the controller.
J
A
N
123
45
Set the DIP switch on the back side of the controller to assign the
number of the controller
J
NO. 1
ON
1234
NO. 3
ON
1234
NO. 2
ON
1234
NO. 4
ON
1234
NO. 9
ON
1234
NO. 11
ON
1234
NO. 10
ON
1234
NO. 12
ON
1234
NO. 5
ON
1234
NO. 7
ON
1234
NO. 6
ON
1234
NO. 8
ON
1234
NO. 13
ON
1234
NO. 15
ON
1234
NO. 14
ON
1234
NO. 16
ON
1234
K
K
Connect the controller cable onto the mainboard (USB 2.0 9 pin)
and controller.
If you want to connect two or more connectors, you can use the bridge
cable to connect the controllers.
M M
Connect the power cable to the 4pin Molex connecter and controller.
L L
J K L M Px 1 x 1 x 1 x 1 x 1N Ox 1 x 1
Controller Power Cable VelcroController Cable Bridge Cable LED Y - Cable MB SYNC Cable
© 2019 Thermaltake Technology Co., Ltd. All Rights Reserved.
www.thermaltake.com
Connect the LED Y-Cable onto the waterblock.
ON
1 2 3 4

Specyfikacje produktu

Marka: Thermaltake
Kategoria: Hardwarekoeling
Model: Pacific V-RX 5700

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z Thermaltake Pacific V-RX 5700, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą