DIS Digital Conference Systems
Distributes up to 8 or 32 audio channels
Connection for up to 180 RA 6013 or RA 6025 Infrared radiators
Built-in mini radiator for audio monitoring
Description
The DT 60xx Digital Transmitter is the central modulator unit in the DIS digital infra-
red system. The system allows participants to listen on headphones to the confer-
ence in a variety of languages. Audio is transmitted wirelessly to the receiver, where
each individual can select the channel and adjust the volume to the headphones.
The system is useful in a variety of installations, such as multipurpose halls, hotels,
or conference centers.
The DT 60xx Digital Transmitter accepts audio from CU 5905/6105/6110 Central
Units, the AO 6004/6008 Audio Output Units or other audio sources, and modulates
these signals onto RF carrier frequencies between 2-8 MHz. These carriers are then
transmitted to the RA 60xx Digital Infrared Radiators for line-of-sight wireless digital
language distribution to the DR 60xx Digital Receivers.
DT 60xx is available in two model variations:
Model Name Number of Channels
DT 6008 8
DT 6032 32
The DIS Digital IR system can transmit audio in four modes. The standard quality
mode uses less bandwidth and can be used for transmitting speech. For music, the
premium quality mode provides near-CD quality.
Mono, standard quality, maximum 32 channels
Mono, premium quality, maximum 16 channels
Stereo, standard quality, maximum 16 channels
Stereo, premium quality, maximum 8 channels
The standard quality mode uses less bandwidth and can be used for transmitting
speech. For music the premium quality mode provides near CD quality.
Features
Distributes audio channels for wireless monitoring of
interpretation or the floor mix
Flexible configuration of channels and channel quality modes
for efficient distribution
Can be used with both the DCS 6000 and the DDS 5900
systems
Automatic distribution of emergency messages to all channels
Auxiliary mode for distribution of music to all channels during
a break
Adjustable sensitivity for each input to enable fine tuning of
audio levels
Test mode for verifying proper connection for each channel
Slave mode for distribution of signals from another transmitter
allows multiple rooms to be used
Built-in mini infra-red radiator for audio monitoring
Radiator and system status indication via display
Configuration of transmitter and system using a single display
and a rotary push button
Transmitter can be assigned a unique name for easy
identification in a multi-transmitter system
Each audio channel can be assigned a unique name. These
names can be selected from a list of options or entered
manually
19" housing for table top use or rack mounting
Hand grips for easy transportation
19" rack mounting brackets, detachable feet and mounting
accessories for modules included
The DT 6008/6032 features multiple channel settings. Each indi-
vidual channel can be set to any of the 8 or 32 channels.
DT 6008/6032 Digital Transmitter
DT 6008/6032 Digital Transmitter
Specifications
Electrical
Audio Frequency
Response
Premium Quality: 20 Hz to 10 kHz (-3 dB)
Standard Quality: 20 Hz to 20 kHz (-3 dB)
Dynamic Range >80 dB
Total Harmonic
Distortion <0.05% @ 1kHz
Crosstalk Attenuation >80 dB @ 1kHz
Signal-to-Noise Ratio >80 dB, A-weighted
Audio Input Level Balanced: -6 to +6 dBV
Unbalanced: +6 to +18 dBV nominal
Impedance
(headphones) 32 Ω to 2
HF Input Nominal 1Vpp, minimal 10 mVpp, 75 Ω
HF Output 1 Vpp, 6 VDC, 75 Ω
Mains Voltage 100 to 240 V, 50 to 60 Hz
Power Consumption operation: 55 W maximum
standby: 29 W
Interconnections
Audio Input
DT 6008: 8x RCA unbalanced; 1 XLR
balanced
DT 6032: 32x RCA unbalanced; 1 XLR
balanced
Emergency Input 1x XLR with terminal block connector
Headphone Input 3.5 mm (1/8") stereo
Antenna Input ( from
another transmitter) 1x BNC; 75 Ω
Antenna Output (to
radiators) 6x BNC; 75
Mechanical
LCD 2 x 16 character
Mounting 2 RU
Controls Rotary push-button
Dimensions (W x H x D) 483 x 87 x 357 mm (with brackets)
Color Grey and black
Weight 4 kg (with mounting brackets)
Temperature range Operation: 5° to 40° C (35 to 80% humidity)
Storage: -20° to 60° C (10 to 80% humidity)
Certifications
The DCS 6000 system conforms to standard IEC 60914. The DIS
Digital Infrared System fully complies with the IEC 61603-PART7,
which is the industry standard for digital infra-red transmission in the
2 to 6 MHz frequency band.
How To Order
8-channel digital IR transmitter DT 6008
32-channel digital IR transmitter DT 6032
XLR to RCA phono cable EC 6105-01
Drawing


Specyfikacje produktu

Marka: Shure
Kategoria: Niesklasyfikowane
Model: DT 6008

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z Shure DT 6008, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje Niesklasyfikowane Shure

Shure

Shure Plus Channels Instrukcja

9 Października 2024
Shure

Shure Plus PLAY Instrukcja

9 Października 2024
Shure

Shure UA864 Instrukcja

9 Października 2024
Shure

Shure SLXD5 Instrukcja

4 Października 2024
Shure

Shure ULX-S Instrukcja

22 Września 2024
Shure

Shure GLXD14+/85 Instrukcja

22 Września 2024
Shure

Shure GLXD124R+/85 Instrukcja

18 Września 2024

Instrukcje Niesklasyfikowane

Najnowsze instrukcje dla Niesklasyfikowane

Stihl

Stihl HT 70 Instrukcja

15 Października 2024
Ernesto

Ernesto H14270 Instrukcja

15 Października 2024
Uniden

Uniden BT MIC KIT Instrukcja

15 Października 2024
Vaude

Vaude Omnis Bike 26 Instrukcja

15 Października 2024
ART

ART ProChannel II Instrukcja

15 Października 2024
Aukey

Aukey DR02J Instrukcja

15 Października 2024
Master Lock

Master Lock 653EURD Instrukcja

15 Października 2024
Roland

Roland FR-18 Diatonic Instrukcja

15 Października 2024