©2013 Shure Incorporated
27A20377 (Rev. 2)
Printed in China
Model Variations
CVB-B/C: Black, Cardioid
CVB-B/O: Black, Omnidirectional
CVB-W/C: White, Cardioid
CVB-W/O: White, Omnidirectional
Note: Model availability depends on region. See your
local Shure dealer or distributor for details.
Centraverse Boundary
Microphone
The Shure Centraverse CVB is a professional boundary
electret condenser microphone for use in desktop installed
sound reinforcement applications. Available in cardioid and
omnidirectional polar patterns and black or white color op-
tions, its low-profile design fits seamlessly within any design
aesthetic.
Features
Superior Shure design and rugged, dependable
construction
Available in cardioid or omnidirectional polar patterns
Attached 12 ft XLR cable
Mounting holes for secure installation
Commshield® technology guards against unwanted
RF interference from portable wireless devices
(smartphones, etc.)
Installation
1. Install two screws into the mounting surface, exactly 24 mm
(15/16 in.) apart. Leave a 5 mm (3/16 in.) gap between the
screw head and the mounting surface. Only use screws with
a flat-bottom head.
2. Place the microphone onto the screws and slide backwards
to lock into place.
3. Connect the XLR cable to a mixer or P.A. system.
Note: This microphone requires +48V phantom power to
operate.
5 mm
(3/16 in.)
24 mm
(15/16 in.)
Microphone Placement
Use the following information to achieve the best results for
each model variation.
① Cardioid
The cardioid model captures sound in front of the microphone
and rejects off-axis sounds. It is best suited to capture one
person or a small group in close proximity to one another.
② Omnidirectional
The omnidirectional model captures sound from all angles. It
is ideal for capturing larger groups and sounds coming from
multiple directions.
Centraverse™ Series
Installed Sound Microphones
CVB
500 Hz
250 Hz
1,000 Hz
4,000 Hz
2,000 Hz
20
15
10
5
0
-30
-25
-20
-15
-10
-5
dB
Hz
20 100 1k 10k 20k
2 ft. (0.6 m) from sound source
500 Hz
250 Hz
1,000 Hz
4,000 Hz
2,000 Hz
20
15
10
5
0
-30
-25
-20
-15
-10
-5
dB
Hz
20 100 1k 10k 20k
2 ft. (0.6 m) from sound source
CVB / C
CVB / O
Cartridge Type
Electret Condenser
Polar Pattern
CVB/O Omnidirectional
CVB/C Cardioid
Frequency Response
70–16000 Hz
Output Impedance
180Ω
Sensitivity
open circuit voltage, @ 1 kHz, typical
CVB/O –28 dBV/Pa[1] (40 mV)
CVB/C –32.5 dBV/Pa[1] (23 mV)
Maximum SPL[2]
1 kHz at 1% THD
CVB/O 117 dB SPL
CVB/C 120 dB SPL
Signal-to-Noise Ratio[3]
Ref. 94 dB SPL at 1 kHz
CVB/O 74 dB
CVB/C 67 dB
Dynamic Range
CVB/O 97 dB
CVB/C 93 dB
Self Noise
equivalent SPL, A-weighted, typical
CVB/O 20 dB SPL
CVB/C 27 dB SPL
Preamplifier Output Clipping Level
@ 1 kHz, at 1% THD
CVB/O -6 dBV
CVB/C -7 dBV
Common Mode Rejection
10 Hz to 100 kHz
>45 dB
Specifications Certifications
Meets essential requirements of all applicable European Directives.
Eligible for CE marking.
The CE Declaration of Conformity can be obtained from Shure Incorporated
or any of its European representatives. For contact information please visit
www.shure.com
The CE Declaration of Conformity can be obtained from: www.shure.com/
europe/compliance
Authorized European representative:
Shure Europe GmbH
Headquarters Europe, Middle East & Africa
Department: EMEA Approval
Jakob-Dieffenbacher-Str. 12
75031 Eppingen, Germany
Phone: 49-7262-92 49 0
Fax: 49-7262-92 49 11 4
Email: EMEAsupport@shure.de
Polarity
Positive pressure on diaphragm pro-
duces positive voltage on pin 2 with
respect to pin 3
Environmental Conditions
Operating
Temperature
–18 to 57°C (0
to 135°F)
Storage
Temperature
–29 to 74°C
(–20 to 165°F)
Relative
Humidity
0 to 95%
Power Requirements
11–52 V DC[4], 2.0 mA
Weight
8 oz. (227 g)
[1] 1 Pa=94 dB SPL
[2] THD of microphone preampli-
fier when applied input signal level
is equivalent to cartridge output at
specified SPL
[3] S/N ratio is the difference be-
tween 94 dB SPL and equivalent
SPL of self noise, A-weighted
[4] All specifications measured with
a 48 Vdc phantom power supply.
The microphone operates at lower
voltages, but with slightly decreased
headroom and sensitivity.
3.5 in.
(88 mm)
2.5 in.
(63 mm)
0.9 in.
(24 mm)
PT. GOSHEN SWARA INDONESIA
Kompleks Harco Mangga Dua Blok L No. 35 Jakarta Pusat
I.16.GSI31.00501.0211
Europe, Middle East, Africa:
Shure Europe GmbH
Jakob-Dieffenbacher-Str. 12,
75031 Eppingen, Germany
Phone: 49-7262-92490
Fax: 49-7262-9249114
Email: info@shure.de


Specyfikacje produktu

Marka: Shure
Kategoria: mikrofon
Model: Centraverse CVB

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z Shure Centraverse CVB, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje mikrofon Shure

Shure

Shure MXA901-R Instrukcja

8 Października 2024
Shure

Shure SBC-DC-903 Instrukcja

5 Października 2024
Shure

Shure SM7dB Instrukcja

29 Września 2024
Shure

Shure MX412SE/C Instrukcja

21 Września 2024
Shure

Shure SBC10-904 Instrukcja

21 Września 2024
Shure

Shure PG27 Instrukcja

20 Września 2024
Shure

Shure TH53 Instrukcja

20 Września 2024
Shure

Shure KSM8 Instrukcja

20 Września 2024
Shure

Shure UA834 Instrukcja

17 Września 2024

Instrukcje mikrofon

Najnowsze instrukcje dla mikrofon

Audio-Technica

Audio-Technica BP4073 Instrukcja

15 Października 2024
Power Dynamics

Power Dynamics PD524 Instrukcja

15 Października 2024
Audio-Technica

Audio-Technica AT4060 Instrukcja

14 Października 2024
Pyle

Pyle PDWM8225 Instrukcja

13 Października 2024
AKG

AKG WMS420 Instrukcja

13 Października 2024
Audio-Technica

Audio-Technica BP892xCH Instrukcja

12 Października 2024
Apart

Apart MDS.DEL Instrukcja

10 Października 2024
BOYA

BOYA BY-V4 Instrukcja

9 Października 2024