Cardioid Condenser Microphone
General Description
The Beta 98H/C miniature cardioid condenser micro-
phone clamps onto the bell of wind instruments or onto
the rim of percussion instruments. The integrated goose-
neck and ratcheting swivel joint allows the mic to be
easily positioned and secured, and an isolation shock-
mount reduces the transmission of instrument vibrations.
A gooseneck angle brace is included to provide better
retention of the desired microphone placement.
Featuring a highly consistent cardioid polar pattern, the
Beta 98H/C provides high gain before feedback and
smooth off-axis rejection. It's ability to handle extremely
high sound presure levels (SPL) makes it ideal for live
sound reinforcement on a variety of instruments.
Features
• Premier live performance microphone with Shure
quality, ruggedness, and reliability
• Uniform cardioid pick-up pattern for maximum gain
before feedback and excellent rejection of off-axis
sound
• Tailored frequency response specifically shaped for
open, natural sound reproduction
• Wide dynamic range for use in high sound pressure
level SPL environments
• Adjustable gooseneck, angle brace and ratcheting
swivel joint allow for optimal microphone positioning
• Compact, lightweight construction provide a low
degree of visibility
• Interchangeable microphone cartridges with different
polar patterns are available
• Snap-fit foam windscreens stay in place, minimizing
wind noise
General Rules for Use
• Do not cover any part of the microphone grille with
your hand, as this will adversely affect microphone
performance.
• Aim the microphone toward the desired sound source
(such as the talker, singer, or instrument) and away
from unwanted sources.
• Place the microphone as close as practical to the
desired sound source.
• Work close to the microphone for extra bass
response.
• For better gain before feedback, use fewer
microphones.
• Keep the distance between microphones at least
three times the distance from each microphone to its
source ("three to one rule").
• Place microphones as far as possible from reflective
surfaces.
• Add a windscreen when using the microphone
outdoors.
• Avoid excessive handling to minimize pickup of
mechanical noise and vibration.
Applications And Placement
The following table lists the most common applications and placement techniques. Keep in mind that microphone
technique is largely a matter of personal taste; there is no one "correct" microphone position.
APPLICATION SUGGESTED MICROPHONE PLACEMENT TONE QUALITY
Reed Instruments Place microphone a few inches from and aiming
into bell.
Bright, minimizes feedback and
leakage.
Brass & Woodwinds Brass: 30 to 90 cm (1 to 3 ft.) away, on-axis with
bell of instrument.
Bright, clear sound.
Woodwinds: 2.5 to 15 cm (1 to 6 in.) away, on-
axis with bell of instrument.
Bright, clear sound.
Bell of instrument 90° off-axis from front of mic. Softer, mellow sound.
Avoiding Pickup of Unwanted
Sound Sources
A cardioid microphone has the greatest sound rejection
at the rear of the microphone. Place the microphone
so that unwanted sound sources, such as monitors
and loudspeakers, are directly behind it. To minimize
feedback and ensure optimum rejection of unwanted
sound, always test microphone placement before a
performance.
BETA 98H/C
MONITOR
P.A.
LOUDSPEAKER
RECOMMENDED LOUDSPEAKER LOCATIONS FOR
CARDIOID MICROPHONES
Power Requirements
This microphone requires phantom power and performs
best with a 48 Vdc supply (IEC-61938). However, it will
operate with slightly decreased headroom and sensitivity
with supplies as low as 11 Vdc.
Most modern mixers provide phantom power. You must
use a microphone cable: XLR-to-XLR or balanced
XLR-to-TRS.
4
Type Electret Condenser
Frequency Response 20 to 20,000 Hz
Polar Pattern Cardioid
Output Impedance 150Ω
Sensitivity
(at 1 kHz, open circuit
voltage)
−56dBV/Pa(1.6mV)
1 Pascal=94 dB SPL
Maximum SPL
(1kHzat1%THD,1kΩ
load)
155 dB SPL (typical)
Equivalent Output
Noise
(A-weighted)
31 dB SPL (typical)
Signal-to-Noise Ratio
(referenced at 94 dB
SPL at 1 kHz)
63 dB
S/N ratio is difference between 94 dB SPL and equivalent SPL of
self noise, A-weighted
Dynamic Range
(at1kHz,1kΩload)
124 dB
132 dB
Preamplifier Output
Clipping Level
(1% THD)
3 dBV (1.4 V)
Polarity Positive pressure on diaphragm produces positive volt-
age on pin 2 with respect to pin 3
Power Requirements 11 to 52 Vdc phantom
Accessories and Parts
Furnished Accessories
Zippered Carrying Bag 95A2398
In-Line Preamplifier (1 piece) RPM626
CERTIFICATION
Eligible to bear CE Marking. Conforms to European EMC Directive 2004/108/EC.
Meets Harmonized Standards EN55103-1:1996 and EN55103-2:1996, for residential
(E1) and light industrial (E2) environments.
The Declaration of Conformity can be obtained from:
Authorized European representative:
Shure Europe GmbH
Headquarters Europe, Middle East & Africa
Department: EMEA Approval
Jakob-Dieffenbacher-Str. 12
75031 Eppingen, Germany
Phone: +49 7262 92490
Fax: +49 7262 9249114
Email: info@shure.de
Optional Accessories
Supercardioid cartridge RPM110
Metal Locking Windscreen A412MWS
Replacement Parts
Snap-Fit Windscreen (4 per package) RK183WS
Cardioid cartridge RPM108
Clamp Assembly (A98D) RPM618
125 Hz
250 Hz
500 Hz
1000 Hz
5000 Hz
10000 Hz
SPECIFICATIONS
Red (to drain) (DC bias)
12
3
2
3
1
CARTRIDGE
PREAMP
XLR CONNECTOR
RC
FILTER
FET
G
D
S
MIC
ELEMENT Black (to source) (audio)
Shield
Wiring Diagram
Proximity Effect
Directional microphones progressively boost bass frequencies as the microphone is
placed in closer proximity to the source. This phenomenon, known as proximity effect,
can be used to create a warmer, more powerful sound.


Specyfikacje produktu

Marka: Shure
Kategoria: mikrofon
Model: Beta 98H/C
Kolor produktu: Czarny
Długość kabla: 3 m
Technologia łączności: Przewodowa
Częstotliwość mikrofonu: 20 - 20000 Hz
Czułość mikrofonu: -56 dB
Typ kierunku mikrofonu: Kardioid
Napięcie pracy: 52 V
Interfejs urządzenia: XLR-3
Waga odbiornika: 65 g
Model: Mikrofon studyjny
Zużycie energii: 1.2 mA
Liczba dołączonych produktów: 1 szt.
Impedencja wyjścia: 150 Ω

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z Shure Beta 98H/C, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje mikrofon Shure

Shure

Shure MXA901-R Instrukcja

8 Października 2024
Shure

Shure SBC-DC-903 Instrukcja

5 Października 2024
Shure

Shure SM7dB Instrukcja

29 Września 2024
Shure

Shure MX412SE/C Instrukcja

21 Września 2024
Shure

Shure SBC10-904 Instrukcja

21 Września 2024
Shure

Shure PG27 Instrukcja

20 Września 2024
Shure

Shure TH53 Instrukcja

20 Września 2024
Shure

Shure KSM8 Instrukcja

20 Września 2024
Shure

Shure UA834 Instrukcja

17 Września 2024

Instrukcje mikrofon

Najnowsze instrukcje dla mikrofon

Audio-Technica

Audio-Technica BP4073 Instrukcja

15 Października 2024
Power Dynamics

Power Dynamics PD524 Instrukcja

15 Października 2024
Audio-Technica

Audio-Technica AT4060 Instrukcja

14 Października 2024
Pyle

Pyle PDWM8225 Instrukcja

13 Października 2024
AKG

AKG WMS420 Instrukcja

13 Października 2024
Audio-Technica

Audio-Technica BP892xCH Instrukcja

12 Października 2024
Apart

Apart MDS.DEL Instrukcja

10 Października 2024
BOYA

BOYA BY-V4 Instrukcja

9 Października 2024