Instrukcja obsługi Sauter FL 100


Przeczytaj poniżej 📖 instrukcję obsługi w języku polskim dla Sauter FL 100 (2 stron) w kategorii Niesklasyfikowane. Ta instrukcja była pomocna dla 2 osób i została oceniona przez 2 użytkowników na średnio 4.5 gwiazdek

Strona 1/2
Sauter GmbH
Ziegelei 1
D-72336 Balingen
E-Mail: info@sauter.eu
Tel: +49-[0]7433- -199 9933
Fax: +49-[0]7433- -149 9933
Internet: www.kern-sohn.com
Instruction Manual
FL
FL- -e-1411 1BA
Table of Contents
1. Introduction
2. Before Use
3. Operation Overview
4. Powering the FL
5. Battery Indicator
6. Fitting Accessories
7. Mounting to a Test Stand
8. Powering up
9. Basic Functions
10. Main Menus
AUTO-OFF
PASS-FAIL
MEMORY
CALIBRATION
DIAGNOSTIC
ABOUT
11. Measurement Practice
12. FL Specications
13. Conversion Factor
14. Declaration of Conformity
1. Introduction
Thank you for choosing the SAUTER FL series instrument.
With correct use and regular re-calibration it will give many
years of accurate and reliable service.
The FL can measure tensile and compressive forces
accurately, being simply used by the operator. It may be
used handheld or mounted a xture or test stand. on
SAUTER oers software and accessories to make the
force gauge even more versatile. Ask your SAUTER
distributor for additional information or visit our website at
www.kern-sohn.com
2. Before Use
After having receiv the unit please check that no ed
physical damage has occurred to the packaging material,
plastic case or the instrument itself. If any damage is
evident, please notify SAUTER immediately.
3. Operation Overview
The most common used features (such as displaying
force, peak hold, zero and changing of displayed units) can
all be done by pressing a single dedicated key identied on
the front panel-see the Basic Functions section.
You can press a menu key to access the gauge
conguration- see the Main Menu section.
4. Powering the FL
The FL is supplied with a set of 4 Nickel Metal Hydride AA
rechargeable batteries. For safety reasons during
transportation the batteries are shipped discharged. To
obtain maximum battery life we recommend that you
charge them with the charger/adaptor supplied for at least
14-16 hours when you rst receive the instrument.
5. Battery Indicator
If battery level is less than 3.9 V, The “battery empty”
message will be displayed and the gauge will power down
automatically.
Important: Only use the adaptor/charger supplied
6. Fitting Accessories
Couple ttings directly to the load cell stem or use an
extension rod. The threads are and have capacities up M6
to 2500 N.
Ensure that the xing does nor contact the force gauge
case. Ensure that anything coupled to the gauge is
screwed finger-tight only. Excessive torque can damage
the load cell and is not covered by warranty.
7. Mounting to a Fixture or Test Stand
The two 10-32 threaded holes, or fours thread holes on M3
the rear of the gauge can be used for mounting the gauge.
A versatile stand mounting plate is available to couple the
force gauge to many brands of test stands.
8. Powering up
As shown in Figure 1 the control panel has eight keys.
Sauter GmbH
Ziegelei 1
D-72336 Balingen
E-Mail: info@sauter.eu
Tel: +49-[0]7433- -199 9933
Fax: +49-[0]7433- -149 9933
Internet: www.kern-sohn.com
Instruction Manual
FL
FL- -e-1411 4BA
Use UP and DOWN key to move the cursor. Press the
ENTER key to select auto-o option and return to main
menu page.
2) PASS-FAIL
The Pass-Fail feature used to set a dened acceptable
maximum and minimum forces gap for measuring. It is
activated by setting the lower level and upper level forces
limit. If the forces value is within the gap level, the display
will show message . Any reading values outside this PASS
gap (higher or lower), the display will show message FAIL.
If you activate this feature the symbol will be shown on PF
main display.
To access menu, Press UP and DOWN to PASS-FAIL
move the cursor point to PASS-FAIL and press the ENTER
key the display will show the Pass-Fail menu page. Press
ESC key to return to the main menu page.
Figure 6
Use LEFT ARROW keys to move the cursor point to the
desired value.
Use UP and DOWN keys to change the value, press and
hold to scroll values. Use RIGHT ARROW key to change
the unit. Press ENTER to save the settings and return to
main menu page.
*Pass-Fail feature will automatically disabled if you set be
LOWER and UPPER = 0 N.
*LOWER must be less than the UPPER.
Example LOWER LEVEL = 0 N, UPPER LEVEL = 20 N
Example LOWER LEVEL = 10 N, UPPER LEVEL = 20 N
Example LOWER LEVEL = 10 N, UPPER LEVEL = 20 N
3) MEMORY
This is used view the saved record, delete current to
record, delete all record and print data of the saved record.
To access menu, go to the main menu page MEMORY
press UP and DOWN to move the cursor point to
MEMORY and press ENTER key the display will show the
memory page. Press ESC key to return to main menu
page.
Figure 7a Memory Page
Press UP and DOWN to change memory page, press and
hold to scroll change memory page. Press PRINT key to
print the memory to the serial port. Press ZERO key to
access the DELETE menu.
Figure 7b Delete last Menu
Press UP and DOWN to select the delete option. If you
selected and press ENTER key, the gauge will return NO


Specyfikacje produktu

Marka: Sauter
Kategoria: Niesklasyfikowane
Model: FL 100

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z Sauter FL 100, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje Niesklasyfikowane Sauter

Sauter

Sauter FK 10 Instrukcja

12 Września 2024
Sauter

Sauter FA 200 Instrukcja

6 Września 2024
Sauter

Sauter FK 500 Instrukcja

5 Września 2024
Sauter

Sauter FK 1K Instrukcja

5 Września 2024
Sauter

Sauter FA 10 Instrukcja

2 Września 2024
Sauter

Sauter FL 200 Instrukcja

2 Września 2024
Sauter

Sauter FL 500 Instrukcja

2 Września 2024
Sauter

Sauter FL 100 Instrukcja

2 Września 2024
Sauter

Sauter HMM Instrukcja

29 Sierpnia 2024

Instrukcje Niesklasyfikowane

Najnowsze instrukcje dla Niesklasyfikowane