Instrukcja obsługi Samsung AC120MXASEH

Samsung pompa ciepła AC120MXASEH

Przeczytaj poniżej 📖 instrukcję obsługi w języku polskim dla Samsung AC120MXASEH (52 stron) w kategorii pompa ciepła. Ta instrukcja była pomocna dla 3 osób i została oceniona przez 2 użytkowników na średnio 4.5 gwiazdek

Strona 1/52
Air conditioner
Installation manual
AC***MXAD*H / AC***MXAS*H
Thank you for purchasing this Samsung air conditioner.
Before operating this unit, please read this manual carefully and retain it for future
reference.
2English
Contents
Safety Information 3
General information 3
Installing the unit 4
Power supply line, fuse or circuit breaker 4
Installation Procedure 5
Step 1 Choosing the installation location 5
Step 2 Fixing the outdoor unit in place 8
Step 3 Connecting the power cables, communication cable, and controllers 9
Step 4 Optional: Extending the power cable 15
Step 5 Connecting the refrigerant pipe 17
Step 6 Optional: Cutting and flaring the pipes 18
Step 7 Installing oil traps 19
Step 8 Connecting up and removing air in the circuit 19
Step 9 Adding refrigerant (R-410A) 20
Step 10 Performing the gas leak test 23
Step 11 Connecting the drain hose to the outdoor unit 24
Step 12 Insulating the refrigerant pipes 24
Step 13 Checking the earthing 25
Step 14 Performing final check and trial operation 26
Extra procedures 29
Pumping down refrigerant 29
Relocating the indoor and outdoor units 29
Using the stop valve 30
Appendix 31
Troubleshooting 31
Technical specifications 32
COMMISSION DELEGATED REGULATION (EU) No 626/2011i) 33
For information on Samsung’s environmental commitments and product-specific regulatory obligations, e.g. REACH,
WEEE, Batteries, visit : samsung.com/uk/aboutsamsung/samsungelectronics/corporatecitizenship/data_corner.html
3English
Safety Information
Safety Information
WARNING
Hazards or unsafe practices that may result in severe
personal injury or death.
CAUTION
Hazards or unsafe practices that may result in minor
personal injury or property damage.
Carefully follow the precautions listed below because
they are essential to guarantee the safety of the
equipment.
WARNING
Always disconnect the air conditioner from the power
supply before servicing it or accessing its internal
components.
Verify that installation and testing operations are
performed by qualified personnel.
Verify that the air conditioner is not installed in an
easily accessible area.
General information
WARNING
Carefully read the content of this manual before
installing the air conditioner and store the manual in
a safe place in order to be able to use it as reference
after installation.
For maximum safety, installers should always
carefully read the following warnings.
Store the operation and installation manual in a safe
location and remember to hand it over to the new
owner if the air conditioner is sold or transferred.
This manual explains how to install an indoor unit
with a split system with two SAMSUNG units. The use
of other types of units with different control systems
may damage the units and invalidate the warranty.
The manufacturer shall not be responsible for
damages arising from the use of non compliant units.
The manufacturer shall not be responsible for damage
originating from unauthorized changes or the
improper connection of electric and requirements set
forth in the “Operating limits” table, included in the
manual, shall immediately invalidate the warranty.
The air conditioner should be used only for the
applications for which it has been designed: the
indoor unit is not suitable to be installed in areas
used for laundry.
Do not use the units if damaged. If problems occur,
switch the unit off and disconnect it from the power
supply.
In order to prevent electric shocks, fires or injuries,
always stop the unit, disable the protection switch
and contact SAMSUNG’s technical support if the unit
produces smoke, if the power cable is hot or damaged
or if the unit is very noisy.
Always remember to inspect the unit, electric
connections, refrigerant tubes and protections
regularly. These operations should be performed by
qualified personnel only.
The unit contains moving parts, which should always
be kept out of the reach of children.
Do not attempt to repair, move, alter or reinstall the
unit. If performed by unauthorized personnel, these
operations may cause electric shocks or fires.
Do not place containers with liquids or other objects
on the unit.
All the materials used for the manufacture and
packaging of the air conditioner are recyclable.
The packing material and exhaust batteries of the
remote controller(optional) must be disposed of in
accordance with current laws.
The air conditioner contains a refrigerant that has
to be disposed of as special waste. At the end of its
life cycle, the air conditioner must be disposed of in
authorized centres or returned to the retailer so that
it can be disposed of correctly and safely.


Specyfikacje produktu

Marka: Samsung
Kategoria: pompa ciepła
Model: AC120MXASEH

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z Samsung AC120MXASEH, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje pompa ciepła Samsung

Instrukcje pompa ciepła

Najnowsze instrukcje dla pompa ciepła

Balay

Balay 3SB288BE Instrukcja

9 Października 2024
Arçelik

Arçelik AHPH-MM08 Instrukcja

9 Października 2024
Arçelik

Arçelik AHPH-MM12 Instrukcja

9 Października 2024
Arçelik

Arçelik AHPH-MM16 Instrukcja

9 Października 2024
Balay

Balay 3SB3091BR Instrukcja

8 Października 2024
Remeha

Remeha Elga Ace 4 kW Instrukcja

7 Października 2024
Miele

Miele TWV780WPS Instrukcja

4 Października 2024
AEG

AEG T858M6OBC Instrukcja

4 Października 2024
AEG

AEG T859M6OBC Instrukcja

4 Października 2024
AEG

AEG T738A4OBC Instrukcja

4 Października 2024