Instrukcja obsługi Salus PMV38


Przeczytaj poniżej 📖 instrukcję obsługi w języku polskim dla Salus PMV38 (1 stron) w kategorii Niesklasyfikowane. Ta instrukcja była pomocna dla 6 osób i została oceniona przez 2 użytkowników na średnio 4.5 gwiazdek

Strona 1/1
white
blueN
E
L
orange
grey
green/yellow
Auxiliary
Switch
M
230V SL
Isolate grey
3 PORT MOTORISED VALVE
PMV31 (1”) PMV32 (22 mm) PMV34 (3/4”) PMV38 (28 mm)
PRODUCT COMPLIANCE
This product complies with the essential requirements of the following EC Directives:
Electro-Magnetic Compatibility Directive 2014/30/EU
Low Voltage Directive 2014/35/EU
RoHS 2011/65/EU
SAFETY INFORMATION
These instructions are applicable to the SALUS Controls model stated on the front cover of this
manual only, and must not be used with any other make or model.
This accessory must be fitted by a Competent person, and installation must comply with the
guidance provided in the current editions of BS7671 (IEE Wiring Regulations) and Part ‘P’ of the
Building Regulations. Failure to comply with the requirements of these publications could lead
to prosecution.
Always isolate the AC Mains supply before removing or refitting the actuator assembly.
Please leave these instructions with the end user where they should be kept in a safe place for
future reference.
INTRODUCTION
A motorised valve is used to control the flow of water in a central heating system. The motorised
valve can be used for control of both heating and hot water, and it works by controlling the flow
of water from the heating boiler to other parts of the system.
There are two types of motorised valve used in domestic heating systems: two port (also called
zone valves), and three port (also called mid position valves). SALUS Controls offers both types
of valve in a range of standard port sizes.
FEATURES
Three port option in 1”, 22mm, 3/4” and 28mm sizes
Removable actuator assembly
Manual lever and position indicator
Spring return
Industry standard wiring
INSTALLATION
Please read the important safety information at the start of this manual before you begin to
install the device.
Before Installation
This valve must only be installed in compatible systems. Before installing, please check that:
The system pipework has been flushed out to remove any residue.
There is enough clearance around the valve to allow removal and refitting of the actuator.
The valve is not installed with the actuator facing down.
The supply voltage is the same as the voltage indicated on the actuator cover.
The mains water pressure and the pressure differentials between valve ports are suitable for
this valve (see Product Specification).
Do not restore the mains supply to the system until all associated items are fully installed.
NOTE: All electrical installation work should be carried out by a suitably qualified Electrician or
other competent person. If you are not sure how to install this motorised valve consult either
with a qualified electrician, heating engineer or your boiler / heating system supplier for advice
on how to continue.
Electrical Connection
The electrical connections to the motorised valve are made using the pre-wired cable. This
simplifies installation, as no connections need to be made to the actuator itself. The connecting
cable uses industry standard colours, and the connection details are shown below:
MANUAL LEVER
There is a lever on the side of the actuator cover: this lever
allows manual operation of the valve, e.g. for refilling and
draining of the system or if the actuator fails. For two way
valves, the lever allows the valve to be kept open; with three
way valves the lever allows both ports A and B to be open
at the same time.
To manually operate the valve, gently push the lever forward and latch it in the MAN position.
The valve will automatically return to AUTO when the actuator is powered up again.
NOTE: Push the manual lever slowly to prevent damage to the actuator motor and gear system.
The valve should be in manual position to be fitted.
ACTUATOR REMOVAL AND REFITTING
The valve actuator can be removed or refitted without having to disturb the valve installation.
Removal:
1. Remove actuator cover
2. Lock lever in ‘MAN’ position
3 Loosen 2 securing screws
4. Lift actuator from valve body.
Re-tting:
1. Remove actuator cover
2. Lock lever in ‘MAN’ position
3. Turn valve stem to parallel position
as indicated
4. Push actuator onto valve
5. Tighten 2 securing screws
6. Release lever and allow to travel back to ‘AUTO
Note: Do not attempt to dismantle the actuator assembly as it contains no user serviceable parts
– dismantling or tampering with the actuator assembly will invalidate the product warranty.
MAINTENANCE
The Motorised Valve requires no special maintenance. Periodically, the outer casing can be
wiped clean using a dry cloth (please DO NOT use solvents, polishes, detergents or abrasive
cleaners, as these can damage the Motorised Valve).
There are no user serviceable parts within the unit; any servicing or repairs should only be carried
out by SALUS Controls or their appointed agents.
Should the Motorised Valve fail to function correctly, check:
The heating system is switched on.
The lever is not latched in the MANUAL position.
PRODUCT SPECIFICATION
Model: 3 port motorized valve PMV31/32/34/38
Type: Motorised valve designed for domestic heating applications.
Electrical
Switching Voltage: 230V AC / 50Hz
Power Consumption: 6W
Response
Opening: 14 seconds
Closing: 3 seconds
Dierential Pressure
Pipe size 3 Way
22mm 0.8 bar
28mm 0.6 bar
Max Static Pressure: 8.6 bar
Operating Temperatures
Min Fluid Temperature: 5 ºC
Max Fluid Temperature: 88 ºC
Environment
Operating Temperature: -10 ºC to + 60 ºC
Storage Temperature: - 20 ºC to + 65 ºC
Protection class: IP20
AUTO MAN
OPEN
SALUS CONTROLS PLC, SALUS HOUSE, DODWORTH BUSINESS PARK SOUTH,
WHINBY ROAD, DODWORTH, BARNSLEY S75 3SP.
SALES: T: +44 (0) 1226 323961 • E: sales@salus-tech.com
TECHNICAL: T: +44 (0) 1226 323961 • E: tech@salus-tech.com
www.salus-controls.com
white
blueN
E
L
orange
grey
green/yellow
Auxiliary
Switch
M
230V SL
230V
230V
When A is open & B is closed; water flows out from A;
When B is open & A is closed; water flows out from B;
Control wire (Power Supply AC 230V) White - Live. Blue - Neutral
When A is open & B is closed; white 0V, Blue is N;
When B is open & A is closed; white 230V, Blue is N;
Auxiliary switch output (COM, NO) Orange = COM. Grey = NO
Yellow/ Green wire = Earth
When valve is open, orange and grey AUX switch is closed. When valve is closed, orange and grey
AUX switch is open. Yellow/Green wire is for earth.
wired with micro switch
wired without micro switch
Note: For basic diverter
valve applications please
isolate / Disregard the
orange wire. But connect
white and grey together..
22mm 0.8 bar
28mm 0.6 bar
3/4” 0.8 bar
1” 0.6 bar


Specyfikacje produktu

Marka: Salus
Kategoria: Niesklasyfikowane
Model: PMV38

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z Salus PMV38, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje Niesklasyfikowane Salus

Salus

Salus TA 22 Instrukcja

9 Września 2024
Salus

Salus CDUK Instrukcja

19 Sierpnia 2024
Salus

Salus THB23030 Instrukcja

17 Sierpnia 2024
Salus

Salus PMV38 Instrukcja

15 Sierpnia 2024
Salus

Salus CP328 Instrukcja

4 Lipca 2024

Instrukcje Niesklasyfikowane

Najnowsze instrukcje dla Niesklasyfikowane

Stihl

Stihl HT 70 Instrukcja

15 Października 2024
Ernesto

Ernesto H14270 Instrukcja

15 Października 2024
Uniden

Uniden BT MIC KIT Instrukcja

15 Października 2024
Vaude

Vaude Omnis Bike 26 Instrukcja

15 Października 2024
ART

ART ProChannel II Instrukcja

15 Października 2024
Aukey

Aukey DR02J Instrukcja

15 Października 2024
Master Lock

Master Lock 653EURD Instrukcja

15 Października 2024
Roland

Roland FR-18 Diatonic Instrukcja

15 Października 2024