Operating and
installation instructions
Read the instructions prior to performing any task!
REMKO ML series
ML 265 DC, ML 355 DC, ML 525 DC, ML 685 DC
Wall mounted units in split design
0245-2020-07 Edition 2, en_GB

R32
Refrigerant
Translation of the original
Read these operating instructions carefully before commis-
sioning / using this device!
These instructions are an integral part of the system and must
always be kept near or on the device.
Subject to modifications; No liability accepted for errors or mis-
prints!

Table of contents
1 Safety and usage instructions 5.............................................................................................................
1.1 General safety notes....................................................................................................................... 5
1.2 Identification of notes...................................................................................................................... 5
1.3 Personnel qualifications.................................................................................................................. 5
1.4 Dangers of failure to observe the safety notes................................................................................ 5
1.5 Safety-conscious working............................................................................................................... 6
1.6 Safety instructions for the operator................................................................................................. 6
1.7 Safety notes for installation, maintenance and inspection ............................................................. 6
1.8 Unauthorised modification and changes......................................................................................... 7
1.9 Intended use................................................................................................................................... 7
1.10 Warranty........................................................................................................................................ 7
1.11 Transport and packaging............................................................................................................... 7
1.12 Environmental protection and recycling........................................................................................ 8
2 Technical data 9........................................................................................................................................
2.1 Unit data.......................................................................................................................................... 9
2.2 Unit dimensions............................................................................................................................. 12
3 Design and function 13............................................................................................................................
3.1 Unit description............................................................................................................................. 13
4 Operation 14.............................................................................................................................................
4.1 General notes................................................................................................................................ 14
4.2 Display on indoor unit.................................................................................................................... 14
4.3 Keys on the remote control........................................................................................................... 15
5 Installation Instructions for qualified personnel 22..............................................................................
5.1 Important notes prior to installation............................................................................................... 22
5.2 Wall openings................................................................................................................................ 22
5.3 Installation materials..................................................................................................................... 22
5.4 Selection of installation location ................................................................................................... 23
5.5 Minimum clearances..................................................................................................................... 24
5.6 Wall bracket.................................................................................................................................. 25
5.7 Connection variants for the indoor unit......................................................................................... 26
5.8 Connection of the indoor unit when the refrigerant piping is installed under the plaster............... 26
5.9 Oil return measures....................................................................................................................... 27
6 Installation 27...........................................................................................................................................
6.1 Installation of the indoor unit......................................................................................................... 27
6.2 Connecting the refrigerant piping.................................................................................................. 28
6.3 Additional notes on connecting the refrigerant piping................................................................... 30
6.4 Leak testing................................................................................................................................... 30
6.5 Adding refrigerant.......................................................................................................................... 31
6.6 Condensate drainage connection and safe drainage.................................................................... 31
7 Electrical wiring 33...................................................................................................................................
7.1 General Information...................................................................................................................... 33
7.2 Connecting the indoor unit............................................................................................................ 33
7.3 Connecting the outdoor unit.......................................................................................................... 34
7.4 Electrical wiring diagram............................................................................................................... 34
7.5 Electrical drawings........................................................................................................................ 36
7.6 Connection of a superordinate controller provided by the customer............................................. 40
3

8 Before commissioning 42.......................................................................................................................
9Commissioning 42...................................................................................................................................
10 Troubleshooting, fault analysis and customer service 44...................................................................
10.1 Troubleshooting and customer service....................................................................................... 44
10.2 Indoor unit fault analysis............................................................................................................. 46
10.3 Resistances of the temperature probes...................................................................................... 57
11 Care and maintenance 60........................................................................................................................
12 Shutdown 62.............................................................................................................................................
13 Exploded view and spare parts lists 63.................................................................................................
13.1 Exploded view - Indoor unit......................................................................................................... 63
13.2 Spare parts list - Indoor unit........................................................................................................ 64
13.3 Exploded view of the outdoor unit............................................................................................... 65
13.4 Spare parts list - Outdoor unit..................................................................................................... 66
14 Index 67.....................................................................................................................................................
REMKO ML series
4

1 Safety and
usage instructions
1.1 General safety notes
Carefully read the operating manual before com-
missioning the units or their components for the
first time. It provides useful tips and notes such as
hazard warnings to prevent injury and material
damage. Failure to follow the directions in this
manual can endanger persons, the environment
and the equipment itself or its components and will
void any claims for liability.
Store this manual and the information required for
the operation of this system (e.g. refrigerant data-
sheet) in the vicinity of the unit.
The refrigerant used in the system is flammable. If
applicable, observe the local safety conditions.
Warning of inflammable substances!
1.2 Identification of notes
This section provides an overview of all important
safety aspects for proper protection of people and
safe and fault-free operation.The instructions and
safety notes contained within this manual must be
observed in order to prevent accidents, personal
injury and material damage.
Notes attached directly to the units must be
observed in their entirety and be kept in a fully
legible condition.
Safety notes in this manual are indicated by sym-
bols. Safety notes are introduced with signal words
which help to highlight the magnitude of the danger
in question.
DANGER!
Contact with live parts poses an immediate
danger of death due to electric shock. Damage
to the insulation or individual components may
pose a danger of death.
DANGER!
This combination of symbol and signal word
warns of a situation in which there is immediate
danger, which if not avoided may be fatal or
cause serious injury.
WARNING!
This combination of symbol and signal word
warns of a potentially hazardous situation,
which if not avoided may be fatal or cause
serious injury.
CAUTION!
This combination of symbol and signal word
warns of a potentially hazardous situation,
which if not avoided may cause injury or mate-
rial and environmental damage.
NOTICE!
This combination of symbol and signal word
warns of a potentially hazardous situation,
which if not avoided may cause material and
environmental damage.
This symbol highlights useful tips and recom-
mendations as well as information for efficient
and fault-free operation.
1.3 Personnel qualifications
Personnel responsible for commissioning, opera-
tion, maintenance, inspection and installation must
be able to demonstrate that they hold a qualifica-
tion which proves their ability to undertake the
work.
1.4 Dangers of failure to observe
the safety notes
Failure to observe the safety notes may pose a risk
to people, the environment and the units. Failure to
observe the safety notes may void any claims for
damages.
5

In particular, failure to observe the safety notes
may pose the following risks:
nThe failure of important unit functions.
nThe failure of prescribed methods of mainte-
nance and repair.
nDanger to people on account of electrical and
mechanical effects.
1.5 Safety-conscious working
The safety notes contained in this manual, the
existing national regulations concerning accident
prevention as well as any internal company
working, operating and safety regulations must be
observed.
1.6 Safety instructions
for the operator
The operational safety of the units and compo-
nents is only assured providing they are used as
intended and in a fully assembled state.
nThe units and components may only be set up,
installed and maintained by qualified per-
sonnel.
nProtective covers (grills) over moving parts
must not be removed from units that are in
operation.
nDo not operate units or components with
obvious defects or signs of damage.
nContact with equipment parts or components
can lead to burns or injury.
nThe units and components must not be
exposed to any mechanical load, extreme
levels of humidity or extreme temperatures.
nRooms in which refrigerant may escape shall
be adequately aerated and ventilated. Other-
wise, a risk of suffocation or fire exists.
nDo not leave children unsupervised when close
to the system.
nCommissioning must be performed by author-
ised specialists exclusively. Deficient commis-
sioning may lead to water leaks, electric
shocks or fire. Commissioning must take place
as described in the user manual.
nOnly instruct authorised specialist personnel to
perform maintenance or servicing.
nThe system is filled with a flammable refrig-
erant. Never thaw any frozen unit components
independently!
nDo not operate any further devices that pro-
duce high heat or naked flames in the same
room.
nAll housing parts and unit openings, e.g. air
inlets and outlets, must be kept clear.
nThe units must be inspected by a service tech-
nician to ensure that they are safe to use and
fully functional at least once yearly. Visual
inspections and cleaning may be performed by
the operator when the units are disconnected
from the mains.
1.7 Safety notes for installation,
maintenance and inspection
nThe refrigerant R32 used in the system is flam-
mable. If applicable, observe the local safety
conditions.
nKeep the cooling circuit clear of other gases
and foreign substances. Only fill the cooling cir-
cuit with the refrigerant R32.
nOnly use the accessories, components and
appropriately marked parts provided. The use
of non-standardised components may result in
water leaks, electric shocks and fire.
nOnly install and store the units in rooms larger
than 4 m2. With a failure to comply, leaks may
result in the room filling with a flammable mix-
ture!
The minimum room size of 4 m2 required for
installation and storage pertains to the basic fill
quantity of the unit. This varies according to the
installation type and total fill quantity of the
system. The calculation must take place in
accordance with valid DIN standards. Make
sure that the installation site is suitable for safe
unit operation.
nOnly mount the unit components on structurally
suitable brickwork.
nThe units must not be installed in rooms in
which further devices that produce heat are
operated (heaters, open hearths).
nMake sure the installation room is sufficiently
ventilated.
nInterventions in the cooling circuit are only pos-
sible after completely draining the refrigerant.
Never solder or grind unit components!
nNote that refrigerant may be odourless.
nNever operate the air conditioning unit in a
humid room, such as a bathroom or laundry
room. If the humidity is too high, this can cause
short circuits on electrical parts.
nThe product must be correctly earthed at all
times, otherwise it may induce electric shocks.
nAttach the condensate drain as described in
the operating manual. The inadequate
drainage of condensate can lead to water
damage in your apartment.
nAll persons who intervene in the cooling circuit
must hold a valid certificate from the chamber
of industry and commerce, which confirms their
ability to work with refrigerant.
REMKO ML series
6

nAppropriate hazard prevention measures must
be taken to prevent risks to people when per-
forming installation, repair, maintenance or
cleaning work on the units.
nThe setup, connection and operation of the
units and its components must be undertaken
in accordance with the usage and operating
conditions stipulated in this manual and comply
with all applicable regional regulations.
nRegional regulations and laws as well as the
Water Ecology Act must be observed.
nThe power supply should be adapted to the
requirements of the units.
nUnits may only be mounted at the points pro-
vided for this purpose at the factory. The units
may only be secured or mounted on stable
structures, walls or floors.
nThe units and components should not be oper-
ated in areas where there is a heightened risk
of damage. Observe the minimum clearances.
nThe units and components must be kept at an
adequate distance from flammable, explosive,
combustible, abrasive and dirty areas or
atmospheres.
nSafety devices may not be modified or
bypassed.
nThe connection of the indoor unit must be
established as a permanent connection; a
detachable, reusable connection is not permis-
sible.
1.8 Unauthorised modification
and changes
Modifications or changes to units and components
are not permitted and may cause malfunctions.
Safety devices may not be modified or bypassed.
Original replacement parts and accessories
authorised by the manufactured ensure safety. The
use of other parts may invalidate liability for
resulting consequences.
1.9 Intended use
Depending on the model, the units and the addi-
tional fittings with which they are equipped are only
intended to be used as an air-conditioner for the
purpose of cooling or heating the air in an
enclosed space.
Any different or additional use is a non-intended
use. The manufacturer/supplier assumes no lia-
bility for damages arising from a non-intended use.
The user bears the sole risk in such cases.
Intended use also includes working in accordance
with the operating and installation instructions and
complying with the maintenance requirements.
The threshold values specified in the technical
data must not be exceeded.
1.10 Warranty
For warranty claims to be considered, it is essential
that the ordering party or its representative com-
plete and return the "certificate of warranty" to
REMKO GmbH & Co. KG at the time when the
units are purchased and commissioned.
The warranty conditions are detailed in the "Gen-
eral business and delivery conditions". Further-
more, only the parties to a contract can conclude
special agreements beyond these conditions. In
this case, contact your contractual partner in the
first instance.
1.11 Transport and packaging
The devices are supplied in a sturdy shipping con-
tainer. Please check the equipment immediately
upon delivery and note any damage or missing
parts on the delivery and inform the shipper and
your contractual partner. For later complaints can
not be guaranteed.
WARNING!
Plastic films and bags etc. are dangerous
toys for children!
Why:
- Leave packaging material are not around.
- Packaging material may not be accessible to
children!
7

1.12 Environmental protection
and recycling
Disposal of packaging
All products are packed for transport in environ-
mentally friendly materials. Make a valuable contri-
bution to reducing waste and sustaining raw mate-
rials. Only dispose of packaging at approved
collection points.
Disposal of equipment and components
Only recyclable materials are used in the manufac-
ture of the devices and components. Help protect
the environment by ensuring that the devices or
components (for example batteries) are not dis-
posed in household waste, but only in accordance
with local regulations and in an environmentally
safe manner, e.g. using certified firms and recy-
cling specialists or at collection points.
REMKO ML series
8

2 Technical data
2.1 Unit data
Series ML 265 DC ML 355 DC ML 525 DC ML 685 DC
Operating mode Inverter wall-mounted room air conditioner combination for
cooling and heating
Nominal cooling output 1) kW 2.6 (0.9-3.2) 3.5 (0.8-4.2) 5.3 (1.7-6.2) 7.2 (2.6-8.4)
Energy efficiency ratio SEER 1) 7.1 7.5 6.7 6.4
Electrical rated power consumption,
cooling 1) kW 0.75 1.05 1.46 2.40
Electrical rated current consumption,
cooling 1) A 3.25 4.74 6.35 10.55
Power consumption, annual, QCE 3) kWh 128 175 290 394
Energy efficiency ratio, cooling 1) A++ A++ A++ A++
Nominal heat capacity 2) kW 2.6 (0.9-3.7) 2.8 (0.8-4.8) 5.3 (1.1-7.0) 5.1 (1.5-9.4)
Energy efficiency ratio SCOP 4) 4.0 4.2 4.0 4.0
Electrical rated power consumption,
heating 2) kW 0.72 1.05 1.45 2.18
Electrical rated current consumption,
heating 2) A 3.44 4.5 6.4 9.5
Power consumption, annual, QHE 3) kWh 875 922 1365 1785
Energy efficiency ratio, heating 2) A+ A+ A+ A+
Max. power consumption kW 2.1 2.2 2.6 3.6
Max. current consumption A 9.5 10.0 11.5 16.0
EDP no. 1635265 1635355 1635525 1635685
1) Air inlet temp. TK 27 °C/FK 19 °C, outside temperature TK 35 °C, FK 24 °C, max. air flow volume,
5 m pipe length
2) Air inlet temp. TK 20 °C, outside temperature TK 7 °C, FK 6 °C, max. air flow volume, 5 m pipe length
3) The specified value is based on results from standard testing.
The actual consumption depends on the use and location of the unit
4) The specified value is based on the average heating period
9

Data specific to indoor unit ML 265 DC
IT
ML 355 DC
IT
ML 525 DC
IT
ML 685 DC IT
Application area
(room volume), approx. m380 110 160 230
Adjustment range, room temperature °C +17 to +30
Air flow volume per stage m3/h 259/429/521 294/478/539 420/505/750 640/830/1020
Sound pressure level per stage 5) dB(A) 22/30/37 22/30/38 27/33/42 30/44/44
Sound pressure level,
Silent/Turbo mode 5) dB(A) 20/39 21/41 26/45 26/46
Sound power level max. dB(A) 53 55 57 62
Enclosure class IP X0
Condensate drainage connection mm 16
Dimensions: H/W/D mm 290/722/187 297/802/189 319/965/215 335/1080/226
Weight kg 7.4 8.2 9.0 12.9
EDP no. 1635267 1635357 1635527 1635687
5) At distance of 1 m in the open air; specified values are maximum values
REMKO ML series
10

Data specific to outdoor unit ML 265 DC
AT
ML 355 DC
AT
ML 525 DC
AT
ML 685 DC
AT
Power supply V/Ph/H
z230/1~/50
Operating range, cooling 7) °C +5 to +30
Operating range, heating 8) °C +5 to +50
Air flow rate, max. m3/h 2000 2000 2100 2700
Enclosure class IP 20
Sound power level max. dB(A) 58 60 64 66
Sound pressure level 5) dB(A) 55 58 59
Refrigerant 6) R32
Refrigerant, basic quantity kg 0.70 0.80 1.25 1.60
CO2 equivalent t 0.47 0.54 0.84 1.08
Refrigerant,
additional quantity >5 m g/m 20 40
Refrigerant piping, max. length m 25 30 50
Refrigerant piping, max. height m 10 20 25
Refrigerant connection,
injection pipe
Inches
(mm) 1/4 (6.35) 3/8 (9.52)
Refrigerant connection, suction
pipe
Inches
(mm) 3/8 (9.52) 1/2 (12.7) 5/8 (15.9)
Dimensions: H/W/D mm 555/770/300 555/770/300 554/800/333 702/845/363
Weight kg 26.4 26.5 37.0 50.0
EDP no. 1635266 1635356 1635526 1635686
5) At distance of 1 m in the open air; specified values are maximum values
6) Contains greenhouse gas according to Kyoto protocol, GWP 675
7) Expandable to -15 °C with WRK-1
8) Expandable to -20 °C with WRH-1
11

2.2 Unit dimensions
Outdoor units
B
C
D
AE
Fig. 1: Outdoor unit ML 265 DC-685 DC AT dimensions
Measurements (mm) A B C D E
ML 265 DC-355 DC AT 770 487 298 555 300
ML 525 DC AT 800 514 340 554 333
ML 685 DC AT 845 540 350 702 363
Indoor units
B
A
C
Fig. 2: Indoor unit dimensions ML 265 DC-685 DC IT(All measurements in mm)
Measurements (mm) A B C
ML 265 DC IT 290 722 187
ML 355 DC IT 297 802 189
ML 525 DC IT 319 965 215
ML 685 DC IT 335 1080 226
We reserve the right to modify the dimensions and design as part of the ongoing technical development
process.
REMKO ML series
12

3 Design and function
3.1 Unit description
The ML series room air conditioners have a
REMKO ML...AT outdoor unit as well as an ML...IT
indoor unit.
In cooling mode, the outdoor unit serves to output
the heat extracted by the indoor unit from the room
being cooled. In heating mode, the heat taken up
by the outdoor unit can be discharged by the
indoor unit into the room to be heated. In both
operating modes, the output produced by the com-
pressor precisely matches requirements, and
thereby regulates the nominal temperature with
minimal temperature deviations. This "inverter
technology" results in energy savings over conven-
tional split systems and also reduces noise emis-
sions to a particularly low level. The outdoor unit
can be installed in an outdoor area or, providing
that certain requirements are met, an indoor area.
The indoor unit is designed to be mounted high up
on the wall, in indoor areas. It is operated by an
infrared remote control.
The outdoor unit consists of a cooling cycle with
compressor, fin condenser, condenser fan,
reversing valve and throttle element. The outdoor
unit is controlled by the regulation of the indoor
unit.
The indoor unit consists of a fin evaporator, evapo-
rator fan, controller and condensate tray.
Floor brackets, wall brackets, refrigerant piping and
condensate pumps are available as accessories.
21
4
3
Fig. 3: Cooling cycle diagram for indoor unit
1: Evaporator
2: Evaporator fan
3: Suction pipe connection
4: Liquid pipe connection
2
1
4
3
5
7
8
9
6
Fig. 4: Cooling cycle diagram for outdoor unit
1: Condenser
2: Condenser fan
3: Reversing valve
4: Compressor
5: Filter dryer
6: Capillary tube throttle element
7: Pressure gauge connection
8: Suction pipe connection valve
9: Liquid line connection valve
1
7
8
9
B
A
4
3
5
6
2
3
5
Fig. 5: System layout
A: Outdoor area
B: Indoor area
1: Indoor unit
2: Outdoor unit
3: Condensate drainage line
4: Condenser fan
5: Power supply cable
6: Shut-off valve
7: Suction pipe
8: Liquid line
9: Control line
Refrigerant piping is used to connect the indoor
unit to the outdoor unit.
13

4 Operation
4.1 General notes
The indoor unit is easily operated using the
standard infrared remote control. The indoor unit
beeps to acknowledge the correct transmission of
data. If it is not possible to program the indoor unit
with the remote control, then it can also be man-
ually operated.
Manual mode
The indoor unit can also be switched on manually
if the infrared remote control is lost/defective.
Manual operation is intended for emergency oper-
ation and is not suitable for basic unit operation.
Please replace the remote control. The key for
manual activation is located below the housing
cover on the right side.
The following settings apply for manual operation:
Pressing once: Automatic mode,
Pressing twice: Cooling mode,
Pressing three times: Unit OFF
Infrared remote control
The infrared remote control sends the programmed
settings a distance of up to 6 m to the receiver of
the indoor unit. Data will only be received correctly
if the remote control is pointed at the receiver and
no objects are obstructing the transmission path.
Two AAA batteries must be inserted into the
remote control in preparation. To do so, remove
the flap from the battery compartment and insert
the batteries the correct way around (see mark-
ings). Removing the batteries causes all stored
data to be lost. The remote control will then access
the default settings, which you are free to cus-
tomise at any time.
max. 6 m
Fig. 6: Maximum distance
Alarms are indicated by a code (see chapter
Troubleshooting and customer service).
NOTICE!
Immediately replace flat batteries with a new
set, otherwise there is a risk of leakage. It is
recommended that the batteries are removed if
the equipment is shut down for longer periods.
Help save on energy consumption in stand-by
mode! If the device, system or component is not
in use, we recommend disconnecting the power
supply. Components with a safety function is
excluded from our recommendation!
4.2 Display on indoor unit
Display
1
Fig. 7: Display
1: Display of coded error message and target
temperature
REMKO ML series
14

4.3 Keys on the remote control
6
8
11
147
9
10
12
13
2
1
4
3
5
Fig. 8: Keys on the remote control
1
"ON/OFF" key
Press this key to switch the air conditioning unit on
and off.
2
Operating mode selection
This key is used to set the desired operating mode.
The automatic, cooling, dehumidification, heating
and recirculation modes are available.
3
Fan speed
Use this key to select the desired fan speed. The
automatic, low, medium and high functions are
available. Note: In the dehumidification mode, the
fan speed cannot be set manually.
4
"SLEEP" key
Activates/deactivates the "SLEEP" function.
Pressing this key will automatically increase or
decrease the target temperature by 1 °C within an
hour in cooling and heating mode respectively.
Press this key to maintain the most convenient
temperature and save energy. This function is only
available in "Cooling", "Heating" and "Auto" modes.
If the unit is working in "SLEEP" mode, this activity
is interrupted by pressing the "MODE", "FAN",
"Speed" or "ON/OFF" keys.
5
"FRESH" key
Press this key to activate/deactivate the ion gener-
ator (air freshener).
6
"TURBO" key
Activation of the turbo function makes it possible to
reach the setpoint in cooling or heating mode as
fast as possible.
7
"SELF CLEAN" key (not available)
This activates the self-clean function on the unit.
8
“ARROW UP” and “ARROW DOWN” keys
“ARROW UP” key
Press the key in order to increase the setpoint in 1
°C steps to a maximum 30°C.
“ARROW DOWN” key
Press the key in order to reduce the setpoint in 1°C
steps to a minimum 17°C.
9
“SILENCE/FP” key
Activates/deactivates the silent mode. Pressing the
key for longer than 2 seconds activates the unit's
frost protection function.
In silent unit mode, the compressor runs at a lower
frequency, and the indoor unit fan rotates at a
slower speed. This obtains particularly silent unit
operation.
The frost protection function can only be activated
in heating mode. The unit operates with a fixed
setpoint of 8°C. The indoor unit displays "FP".
Pressing the ON/OFF, SLEEP, FP, Mode, FAN or
up or down arrow key, the frost protection function
is deactivated.
15

10
"TIMER ON" key
Press this key to activate the unit start delay time.
Each press of this key increases the delay time by
30 minutes. When the set time on the display
exceeds 10.0, each press of the button increases
the set time by 60 minutes. To deactivate the delay
time, set the time to 0.0.
11
"TIMER OFF" key
This key can be used to program the delayed
switch-off time. Each press of this key increases
the switch-off time by 30 minutes. When the set
time on the display exceeds 10.0, each press of
the button increases the set time by 60 minutes. To
deactivate the switch-off time, set the time to 0.0.
12
3-D swing mode
Press this key to start or stop the swing mode.
With the 2-point key, you can adjust the horizontal
fin on the left side and the vertical fin on the right
side. Press this key once to change the angle by 6
degrees. Pressing the key for 2 seconds stops the
swing function. When the swing function is
stopped, LC appears on the display for three sec-
onds.
13
"FOLLOW ME" key
This key can be used to activate/deactivate the
FOLLOW ME function. In this mode, the room tem-
perature is measured on the remote control. This
sends a signal to the indoor unit every 3 minutes. If
the remote control does not send a signal to the
indoor unit for 7 minutes, this mode is automati-
cally deactivated.
14
"LED" key
This activates/deactivates the display on the indoor
unit.
Indicators on the LCD
2
1
4
36
9
8
10
5
7
11
13 12
Fig. 9: Indicators on the LCD
1: Mode indicator - shows the current operating
modes, including Auto ( ), Cooling ( ),
Dehumidification ( ), Heating ( ), Fan ( )
and back to Auto ( ) mode.
2: Signal transmission symbol. This symbol
appears when signals are being transmitted
from the remote control to the indoor unit.
3: ON/OFF symbol. This symbol appears when
the "ON/OFF" key is pressed. Pressing this
key again causes the indicator to go out.
4: TIMER ON symbol. This symbol appears
when TIMER ON is switched on.
5: ECO function (not available)
6: TIMER OFF symbol. This symbol appears
when TIMER OFF is switched on.
7: Battery charge status (weak)
8: Sleep symbol. This symbol appears when the
"Sleep" function is activated. Pressing this key
again causes the indicator to go out.
9: Temperature/Timer symbol. Shows the tem-
perature setting (-17°C~30°C). If "FAN" mode
is selected, the temperature setting is not dis-
played. In Timer mode, the ON and OFF set-
tings appear for the TIMER.
10: FOLLOW ME symbol. This symbol appears
when the "Follow me" function is activated.
11: Display of ion generator active (optional)
12: Fan speed symbol. This is where the selected
fan speeds are displayed: AUTO (no indicator)
and the three fan speed settings: (slow),
(medium) and
(fast). The fan speed is set to "Automatic"
when either "Auto" or "Dehumidification" mode
is activated.
13: Silent mode active (optional)
REMKO ML series
16

The illustration of the LCD with all of the sym-
bols present is only intended to provide a
clearer overview. During operation, only those
symbols relevant to the respective functions
appear on the display.
Key functions
A symbol is shown on the display to indicate that
the settings are being transferred.
“Auto” mode (please observe notes!)
Make sure that the indoor unit is connected to the
power supply, and is switched on.
The operating mode indicator on the display of the
indoor unit begins to flash.
1. "MODE"Press the key to select "Auto"
mode.
2. "Arrow up/down"Press the key to set the
desired temperature. The temperature can
be set between 17 and 30°C, in increments
of 1°C.
3. "ON/OFF"Press the key to switch on the air
conditioning unit.
1
3
2
Fig. 10: "Auto" mode
"Cooling", "Heating" and "Recirculation" mode
Make sure that the indoor unit is connected to the
power supply, and is switched on.
1. "MODE"Press the key to select from oper-
ating modes "Cooling", "Heating" or "Recircu-
lation".
2. "Arrow up/down"Press the key to set the
desired temperature. The temperature can
be set between 17 and 30°C, in increments
of 1°C.
3. "FPress the AN" key to select from the four
fan speeds (Auto, slow, medium and fast).
4. "ON/OFF"Press the key to switch on the air
conditioning unit.
1
4
2
3
Fig. 11: "Cooling", "Heating" and "Recirculation"
mode
17

"Dehumidification" mode
Make sure that the indoor unit is connected to the
power supply, and is switched on.
The operating mode indicator on the display of the
indoor unit begins to flash.
1. "MODE"Press the key to select "Dehumidifi-
cation" mode.
2. The temperature setting on the remote con-
trol has no effect on unit operation.
3. "ON/OFF"Press the key to switch on the air
conditioning unit.
1
3
2
Fig. 12: "Dehumidification" mode
In the “Dehumidification” mode, manual selec-
tion of the fan speed is not possible! Please
note that temperature pre-selection is not pos-
sible and the dehumidified room can cool dra-
matically!
"Timer" mode
Press the "TIMER ON" key to set the "switch-on
time" and the "TIMER OFF" key to set the "switch-
off" time for the unit.
Setting the “switch-on time”
1. Press the "TIMER ON" key. The remote con-
trol shows "TIMER ON", the last "switch-on
time" setting and the symbol "H" appear on
the display. The unit is now ready to reset the
"switch-on time" and to start "TIMER ON"
mode.
2. Press the "TIMER ON" key again to set the
desired "switch-on time". Each time the key
is pressed, the time is increased by half an
hour between 0 and 10 hours, and by an
hour between 10 and 24 hours.
3. Once these settings have been made, there
is a one second delay before the remote con-
trol transmits the signal to the indoor unit.
Then, after approx. two seconds, the "H"
symbol disappears from the LCD display, and
the set temperature appears again on the
display.
2
1
Fig. 13: "Timer" mode
REMKO ML series
18

Setting the “switch-off time”
1. Press the "TIMER OFF" key. The remote
control shows "TIMER OFF", the last "switch-
off time" setting and the symbol "H" appear
on the display. The unit is now ready to reset
the "switch-off time" and to stop "TIMER
OFF" mode.
2. Press the "TIMER OFF" key again to set the
desired "switch-off time". Each time the key
is pressed, the time is increased by half an
hour between 0 and 10 hours, and by an
hour between 10 and 24 hours.
3. Once these settings have been made, there
is a one second delay before the remote con-
trol transmits the signal to the indoor unit.
Then, after approx. two seconds, the "H"
symbol disappears from the LCD display, and
the set temperature appears again on the
display.
–When Timer mode is selected, the remote
control automatically transfers the timer
signal to the indoor unit for the specified
period of time. Therefore, you should hold
the remote control in a location where it can
transfer the signal to the indoor unit without
interference.
–The effective operation for the time settings
by the remote control for the timer function
is restricted to the following settings:
0.5, 1.0, 1.5, 2.0, 2.5, 3.0, 3.5, 4.0, 4.5, 5.0,
5.5, 6.0, 6.5, 7.0, 7.5, 8.0, 8.5, 9.0, 9.5, 10,
11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21,
22, 23 and 24.
Example TIMER function settings
"TIMER ON" (Auto on mode)
Example:
You want the air conditioning unit to switch on 2
hours from the time it was programmed
1. Press the "TIMER ON" key. The last oper-
ating time setting for the timer, and the "H"
symbols, appear on the display.
2. Press the "TIMER ON" key until the desired
start time is shown in the "TIMER ON" area
on the remote control.
3. Wait for 3 seconds and the temperature
appears again in this area of the digital dis-
play. The "TIMER ON" indicator stays lit, and
this function is activated.
Start
O
2 hours laterSet time
Fig. 14: "TIMER ON" example
"TIMER OFF" (Auto off mode)
Example:
You want the air conditioning unit to switch off 4
hours from the time it was programmed.
1. Press the "TIMER OFF" key. The last oper-
ating time setting for the timer, and the "H"
symbols, appear on the display.
2. Press the "TIMER OFF" key until "4H" is
shown in the "TIMER OFF" area on the
remote control.
3. Wait for 3 seconds and the temperature
appears again in this area of the digital dis-
play. The "TIMER OFF" indicator stays lit,
and this function is activated.
Stop
On
4 hours laterSet time
Fig. 15: "TIMER OFF" example
19

Combined TIMER (setting "TIMER ON" and
"TIMER OFF" at the same time)
"TIMER OFF "TIMER ON"ð
(On Stop Start)ð ð
Example:
You want the air conditioning unit to switch off in
two hours from the time it was programmed, and
switch back on ten hours later.
1. Press the "TIMER OFF" key.
2. Press the "TIMER OFF" key again until the
desired stop time is shown in the "TIMER
OFF" area on the remote control.
3. Press the "TIMER ON" key.
4. Press the "TIMER ON" key again until "10H"
is shown in the "TIMER ON" area on the
remote control.
5. Wait for 3 seconds and the temperature
appears again in this area of the digital dis-
play. The "TIMER ON" and "TIMER OFF"
indicators stay lit, and this function is acti-
vated.
On
Set time
Stop
Start
2 hours later
after setting
10 hours later
after setting
Fig. 16: "TIMER OFF" / "TIMER ON" example
"TIMER ON ð"TIMER OFF"
(Off Start Stop)ð ð
Example:
You want the air conditioning unit to switch on in
two hours from the time it was programmed, and
switch back off five hours later.
1. Press the "TIMER ON" key.
2. Press the "TIMER ON" key again until "2.0H"
is shown in the "TIMER ON" area on the
remote control.
3. Press the "TIMER OFF" key.
4. Press the "TIMER OFF" key again until
"5.0H" is shown in the "TIMER OFF" area on
the remote control.
5. Wait for 3 seconds and the temperature
appears again in this area of the digital dis-
play. The "TIMER ON" and "TIMER OFF"
indicators stay lit, and this function is acti-
vated.
O
Set time
Stop
Start
2 hours later
after setting
5 hours later
after setting
Fig. 17: "TIMER ON" / "TIMER OFF" example
REMKO ML series
20

SLEEP function
The sleep function saves energy while you sleep.
This function is activated by pressing the key on
the remote control. Press the key before going to
sleep. In cooling mode, the unit automatically
increases the set room temperature by 1 °C after 1
hour. After one more hour, the room temperature is
increased by an additional 1 °C. In heating mode,
the room temperature is decreased within the first
two hours of operation by 2°C. After 7 hours of unit
operation, the unit switches off automatically in
cooling and heating mode.
This function is not available in the modes recircu-
lation and dehumidification!
1
Fig. 18: "Sleep" function
Setpoint After 7 hours
unit OFF
1 hr 1 hr
Fig. 19: Sleep mode
21

5 Installation Instructions for qualified personnel
5.1 Important notes prior to instal-
lation
nTransport the unit in its original packaging as
close as possible to the installation location.
You avoid transport damage by doing so.
nCheck the contents of the packaging for com-
pleteness and check the unit for visible trans-
port damage. Report any damage immediately
to your contractual partner and the shipping
company.
nLift the unit on the corners and not on the
refrigerant or condensate drainage connec-
tions.
nThe refrigerant piping (liquid and suction pipe),
valves and connections must be insulated to
make them vapour diffusion proof. If necessary
also insulate the condensate drainage line.
nSelect an installation location which allows air
to freely flow through the air inlet and outlet
(see section "Minimum clearances")
nDo not install the unit in the immediate vicinity
of devices which generate intensive thermal
radiation. Installation in the vicinity of thermal
radiation reduces the unit output.
nOnly open the shut-off valves on the refrigerant
piping after installation is complete.
nSeal off open refrigerant piping with suitable
caps or adhesive strips to prevent the infiltra-
tion of moisture and never kink or compress
the refrigerant piping.
nAvoid unnecessary bends. This minimises the
pressure loss in the refrigerant piping and
ensures that the compressor oil can flow back
without obstruction.
nMake special preparations regarding the oil
return if the outdoor unit is located above the
indoor unit (see section "Oil return measures").
nAdd refrigerant if the basic length of the refrig-
erant piping exceeds 5 metres. For the quantity
of additional refrigerant, refer to chapter
"Adding refrigerant".
nPerform all electrical wiring in accordance with
applicable DIN and VDE standards.
nEnsure the electrical cables are properly con-
nected to the terminals, otherwise there is a
risk of fire.
nOnly use the fasteners contained in the scope
of delivery with the units.
nUse four supports and the associated hooks to
attach the ceiling cassette (only applies to
ceiling cassettes).
nUse the insulated condensate hose in the
scope of delivery as a junction piece to the
continuing condensate drain. Secure the con-
densate drain with the supplied clamps.
5.2 Wall openings
nA wall opening of at least 70mm diameter and
10mm incline from the inside to the outside
must be created.
nTo prevent damage to the lines, the interior of
the wall opening should be padded or, for
example, lined with PVC pipe (see figure).
nAfter installation has been completed, use a
suitable sealing compound to close off the wall
opening, taking account of fire protection regu-
lations (responsibility of customer). Do not use
cement or lime containing substances!
21 5
3 4
Fig. 20: Wall opening
1: Liquid line
2: Control line
3: Condensate drainage line
4: Suction pipe
5: PVC pipe
5.3 Installation materials
The indoor unit is attached to the wall by a wall
bracket and 4 screws (to be provided by the cus-
tomer).
The outdoor unit is attached by 4 screws and a
wall bracket to the wall or fixed by a floor bracket to
the ground.
REMKO ML series
22

5.4 Selection of installation
location
Indoor unit
The indoor unit is designed for horizontal wall
installation above doors. However, it can also be
used in the upper wall area (min. 1.75m above the
floor).
Outdoor unit
The outdoor unit is designed for horizontal installa-
tion on a base in outdoor areas. The installation
site must be level, flat and firm. The unit should
also be secured to prevent it from tipping over. The
outdoor unit can be set up outside as well as inside
a building. For external installation, please observe
the following notes to protect the unit from the
influence of the weather.
Rain
For floor or roof set-up, the unit should be installed
with at least 10cm ground clearance. A floor
bracket is available as an optional accessory.
Sun
The condenser on the outdoor unit emits heat.
Exposure to sunlight further increases the temper-
ature of the fins and reduces the heat released by
the finned heat exchanger. The outdoor unit should
be installed on to the north side of the building
whenever possible. If necessary, take measures to
provide sufficient shade (responsibility of cus-
tomer). One possible solution is to build a small
roofed area over the unit. These measures should
not affect the flow of warm outlet air.
Wind
If the unit is being installed in windy areas, ensure
that the warm outlet air is discharged in the pre-
vailing wind direction. If this is not the possible, it
may be necessary to install a windbreak (to be pro-
vided by the customer). Ensure that the windbreak
does not adversely affect the air intake to the unit.
An additional stabilization is recommended. This
can, for example, be realized with ropes or other
structures.
1
Fig. 21: Windbreak
1: Wind
Snow
The unit should be wall-mounted in areas of heavy
snowfall. Installation should be at least 20cm
above the expected level of snow to prevent snow
from entering the outdoor unit. An optional wall
bracket is available as an accessory.
20 cm
1
Fig. 22: Minimum clearance to snow
1: Snow
Installation inside buildings
nEnsure that heat can dissipate adequately
when placing the outdoor unit in cellars, lofts,
adjoining rooms or halls (Fig. 23).
nInstall an additional fan with a rated flow com-
parative to that of the outdoor unit being
installed in the room and which can compen-
sate any additional pressure loss in ventilation
ducts (Fig. 23).
nComply with any regulations and conditions
affecting the statics of the building. If neces-
sary, fit acoustic installation.
23

2
1
K
3
W3
Fig. 23: Installation inside buildings
K: Cold fresh air / W: Warm air
1: Outdoor unit / 2: Additional fan
3: Air shaft
5.5 Minimum clearances
Observe the minimum clearances to allow access for maintenance and repair work and facilitate optimum air
distribution.
2
1
2
1
A
B
C
D
E
E
C
A
B
F
IT AT
Fig. 24: Minimum clearances of the indoor unit and outdoor unit
AT: Outdoor unit / IT: Indoor unit 1: Air inlet / 2: Air outlet
Measure-
ments (mm)
Indoor units Outdoor units
ML 265 DC-685 DC IT ML 265 DC-685 DC AT
A 120 150
B 1500 700
C 120 400
D - 150
E 120 200
F 1700 -
REMKO ML series
24

5.6 Wall bracket
A B
C
D
G
F
E
H
Fig. 25: Wall bracket for indoor units ML 265 DC-685 DC IT (rear view)
Measurements (mm) A B C D E F G H
ML 265 DC IT 372 350 37 50 100 197 542 180
ML 355 DC IT 375 427 43 44 111 204 545 257
ML 525 DC IT 543 423 53 55 111 135 821 144
ML 685 DC IT 527 553 53.5 47 44 219 780 300
25

5.7 Connection variants for the indoor unit
The following connection variants can be used for the refrigerant, condensate and control lines.
D
C
D
B
A
C
A
B
Fig. 26: Connection variant (view from the rear)
A: Infeed of the refrigerant piping at the wall, left
B: Infeed of the refrigerant piping through the wall,
left
C: Outlet through the wall, right
D: Outlet at the wall, right (the refrigerant piping
must be bent through 180 degrees for this)
NOTICE!
A flare connection may only be established outside the room. Detachable, reusable connections are not
permissible inside!
5.8 Connection of the indoor unit when the refrigerant piping is installed
under the plaster
If the customer routes the refrigerant piping to the unit underneath the plaster, observe the following note.
The principal connection options can be found in the "Connection variants for the indoor unit" and "W all
bracket" chapters.
If the refrigerant piping is routed underneath the plaster, ensure that the customer-fitted refrigerant piping
does not protrude from the wall at a 90° angle. As a result of the required bending radius, the unit would then
be very difficult to connect or would possibly be impossible to fasten to the wall mount.
For this reason, route the customer-fitted refrigerant piping with as flat an angle as possible (<30°) out of the
wall, from the left and into the unit. (see Fig. 27).
Fig. 27: Under the plaster installation (View from above)
REMKO ML series
26

5.9 Oil return measures
If the outdoor unit is installed at a higher level than
the indoor unit, suitable oil return measures must
be taken. Usually, an oil pump bend is installed for
every 7 metres of height difference.
1
A
B
Fig. 28: Oil return measures
A: Outdoor unit
B: Indoor unit
1: 1 x oil pump bend in suction pipe to outdoor
unit every 7 metres of height difference, radius:
50 mm
6 Installation
6.1 Installation of the indoor unit
NOTICE!
Installation should only be performed by author-
ised specialists.
The unit is attached by means of a wall bracket,
considering the air discharge side located in the
lower part.
1. Mark the mounting points on the structurally
permissible building sections according to the
dimensions of the wall bracket.
2. If necessary, remove the break out opening
of the housing.
3. Connect the refrigerant piping, electrical
cables and condensate drainage line to the
indoor unit as described below.
4. Hang the indoor unit onto the wall bracket by
tilting it back slightly and by pressing the
bottom part of the unit against the bracket.
5. Check again that the unit is level. (Fig. 29)
Fig. 29: Horizontal positioning
The wall bracket for the units must be attached
with suitable screws and anchors.
27

6.2 Connecting the refrigerant
piping
The refrigerant piping is connected (responsibility
of the customer) on the back side of the units.
Please note that a flare connection is only permis-
sible outside the enclosed room. If this is not pos-
sible on site, the connection of the indoor unit must
be established as a permanent connection (e.g.
soldered).
It may be necessary to fit a reducer or flared
adapter to the indoor unit. These fittings are
included with the indoor unit as an accessory kit.
Once installed, the connections should be insu-
lated to make them vapour diffusion proof.
NOTICE!
Installation should only be performed by author-
ised specialists.
NOTICE!
The unit is factory filled with dry nitrogen for
leak testing purposes. The pressurised nitrogen
is released when the union nuts are undone.
NOTICE!
Use only tools which are approved for use in an
HVAC environment. (z. B.: bending pliers, pipe/
tubing cutters, de-burrers and flaring tools). Do
not cut refrigerant pipes with a saw.
NOTICE!
All work must be carried out in a way that pre-
vents dirt, particles, water etc. from entering,
refrigerant lines!
The following instructions describe the installation
of the cooling cycle and the assembly of the indoor
unit and the outdoor unit.
1. The required pipe diameters are given in the
table "Technical data".
2. Install the indoor unit and connect the refrig-
erant piping as described in the operating
manual for the indoor unit.
3. Use the wall or floor brackets to fit the out-
door unit against structural parts approved to
support the static load (refer to the installa-
tion instructions for the brackets).
4. Ensure that structure-borne sound is not
transferred to parts of the building. Use vibra-
tion dampers to reduce the effects of struc-
ture-borne sound!
5. Lay the refrigerant piping from the indoor unit
to the outdoor unit. Ensure that the fasten-
ings are adequate and if necessary, take
appropriate oil return measures!
6. Remove the factory-fitted protective caps and
union nuts on the connections. These should
be used later in the installation process.
7. Before flanging the refrigerant piping, ensure
that the union nut is fitted on the pipe.
8. Prepare the laid refrigerant pipings as shown
below (Fig. 30 and Fig. 31).
9. Verify that the shape of the flange is correct
(Fig. 32).
10. First connect and hand-tighten the refrigerant
piping to ensure it is correctly seated.
11. Then tighten the fittings with 2 appropriately-
sized open-ended spanners. Use one
spanner to counter the force when tightening
the fitting (Fig. 33).
12. Use insulation hoses which are designed for
this temperature range and are diffusion
proof.
13. Observe the permitted bending radius for the
refrigerant piping during installation. Never
bend a pipe twice in the same place. Brittle-
ness and cracking can result.
14. Apply appropriate heat insulation to the
installed refrigerant piping, including con-
nector.
15. Take the same action at the shut-off valves
for all subsequent refrigerant piping.
REMKO ML series
28

Label the refrigerant piping (injection and suc-
tion pipes) as well as the associated electrical
control lines of each interior unit with a letter.
Only connect the lines to their associated con-
nections.
NOTICE!
Always pay attention to the affiliation of the
electrical lines and refrigerant piping! The con-
nections of the individual circuits must not be
mixed up. Mixing up the assignment of control
lines and refrigerant piping can have fatal con-
sequences (compressor damage)!
Commissioning of the individual circuits must
be carried out successively.
2
1
Fig. 30: Deburring the refrigerant piping
1: Refrigerant piping
2: Deburrer
1
Fig. 31: Flanging the refrigerant piping
1: Flanging tool
Fig. 32: Correct flange shape
29

2
1
Fig. 33: Tightening the fitting
1: Tighten with the first open-ended spanner
2: Counter with the second open-ended spanner
Pipe dimension
in inches
Tightening torque
in Nm
1/4" 15-20
3/8" 33-40
1/2" 50-60
5/8" 65-75
3/4" 95-105
6.3 Additional notes on connecting
the refrigerant piping
nWhen combining the outdoor unit with some
indoor units, the procedure for connecting the
refrigerant piping may differ. Install the pro-
vided reducer or expansion fittings to the
indoor unit.
nIf the basic length of the connecting line
exceeds 5m, add refrigerant when commis-
sioning the system for the first time (see
chapter "Adding refrigerant").
6.4 Leak testing
Once all the connections have been made, the
pressure gauge station is attached to the Schrader
valve as follows (if fitted):
red = small valve = high pressure
blue = large valve = suction pressure
Once the connection has been made successfully,
the leak test is carried out with dry nitrogen.
Leak testing involves spraying a leak detection
spray onto the connections. If bubbles are visible,
the connections have not been made properly. In
that case, tighten the connection or, if necessary,
create a new flange.
After completing a successful leak test, the excess
pressure in the refrigerant piping is removed and a
vacuum pump with an absolute final partial pres-
sure of min. 10 mbar is used to remove all of the
air and empty the pipes. Any moisture present in
the pipes will also be removed.
NOTICE!
A vacuum of at least 20 mbar must be pro-
duced!
The time required to generate the vacuum is
dependent on the final pressure pipe volume of the
indoor units and the length of the refrigerant piping.
However, the process will take at least 60
minutes. Once any foreign gases and humidity
have been completely extracted from the system,
the valves on the pressure gauge station are
closed and the valves on the outdoor unit are
opened as described in the "Commissioning" sec-
tion.
REMKO ML series
30
Specyfikacje produktu
Marka: | Remko |
Kategoria: | klimatyzacja |
Model: | ML 265 DC |
Potrzebujesz pomocy?
Jeśli potrzebujesz pomocy z Remko ML 265 DC, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą
Instrukcje klimatyzacja Remko

11 Stycznia 2025

27 Grudnia 2024

27 Grudnia 2024

27 Grudnia 2024

27 Grudnia 2024

27 Grudnia 2024

27 Grudnia 2024

27 Grudnia 2024

27 Grudnia 2024

27 Grudnia 2024
Instrukcje klimatyzacja
- klimatyzacja Bauknecht
- klimatyzacja Samsung
- klimatyzacja Electrolux
- klimatyzacja DeLonghi
- klimatyzacja AEG
- klimatyzacja Balay
- klimatyzacja Beko
- klimatyzacja LG
- klimatyzacja Gorenje
- klimatyzacja LERAN
- klimatyzacja Sharp
- klimatyzacja TCL
- klimatyzacja Russell Hobbs
- klimatyzacja Philips
- klimatyzacja Livoo
- klimatyzacja Dometic
- klimatyzacja Bosch
- klimatyzacja SHE
- klimatyzacja Candy
- klimatyzacja Whirlpool
- klimatyzacja Fujitsu
- klimatyzacja Ferroli
- klimatyzacja Easy Home
- klimatyzacja Midea
- klimatyzacja Kärcher
- klimatyzacja Hisense
- klimatyzacja Infiniton
- klimatyzacja Panasonic
- klimatyzacja Theben
- klimatyzacja Nedis
- klimatyzacja Be Cool
- klimatyzacja Medion
- klimatyzacja Black & Decker
- klimatyzacja OK
- klimatyzacja Adler
- klimatyzacja Toshiba
- klimatyzacja Tesla
- klimatyzacja Westinghouse
- klimatyzacja Rinnai
- klimatyzacja Domo
- klimatyzacja GE
- klimatyzacja Ardes
- klimatyzacja Taurus
- klimatyzacja Orbegozo
- klimatyzacja Blaupunkt
- klimatyzacja Brandt
- klimatyzacja Vivax
- klimatyzacja Siemens
- klimatyzacja Danby
- klimatyzacja Einhell
- klimatyzacja Grundig
- klimatyzacja APC
- klimatyzacja Haier
- klimatyzacja Sigma
- klimatyzacja Jocel
- klimatyzacja Hyundai
- klimatyzacja Bimar
- klimatyzacja Rowenta
- klimatyzacja Mesko
- klimatyzacja Master
- klimatyzacja Honeywell
- klimatyzacja Concept
- klimatyzacja Tripp Lite
- klimatyzacja ECG
- klimatyzacja Unold
- klimatyzacja Remeha
- klimatyzacja Truma
- klimatyzacja Ozito
- klimatyzacja Sanus
- klimatyzacja Broan
- klimatyzacja Hotpoint
- klimatyzacja Kenwood
- klimatyzacja Sungrow
- klimatyzacja Friedrich
- klimatyzacja Trisa
- klimatyzacja Ariston Thermo
- klimatyzacja Zelmer
- klimatyzacja Mestic
- klimatyzacja Wilfa
- klimatyzacja BLUEPALM
- klimatyzacja Amana
- klimatyzacja Hotpoint Ariston
- klimatyzacja Furrion
- klimatyzacja Bomann
- klimatyzacja Teesa
- klimatyzacja Emerio
- klimatyzacja Wood's
- klimatyzacja Create
- klimatyzacja H.Koenig
- klimatyzacja InAlto
- klimatyzacja Meireles
- klimatyzacja Melissa
- klimatyzacja TechniSat
- klimatyzacja Daikin
- klimatyzacja Alaska
- klimatyzacja Stirling
- klimatyzacja MPM
- klimatyzacja OneConcept
- klimatyzacja Philco
- klimatyzacja Corbero
- klimatyzacja Zanussi
- klimatyzacja Ravanson
- klimatyzacja Thermex
- klimatyzacja GoldAir
- klimatyzacja Koenic
- klimatyzacja Trotec
- klimatyzacja Thomson
- klimatyzacja Klarstein
- klimatyzacja Manta
- klimatyzacja Vaillant
- klimatyzacja Bavaria
- klimatyzacja Cecotec
- klimatyzacja Waeco
- klimatyzacja Camry
- klimatyzacja NewAir
- klimatyzacja Keystone
- klimatyzacja Qlima
- klimatyzacja HTW
- klimatyzacja Sôlt
- klimatyzacja Eden
- klimatyzacja GUTFELS
- klimatyzacja TriStar
- klimatyzacja Exquisit
- klimatyzacja Bartscher
- klimatyzacja Mitsubishi
- klimatyzacja Dimplex
- klimatyzacja Baxi
- klimatyzacja Arçelik
- klimatyzacja Lavorwash
- klimatyzacja Gree
- klimatyzacja DCG
- klimatyzacja Daizuki
- klimatyzacja G3 Ferrari
- klimatyzacja Omega Altise
- klimatyzacja AKAI
- klimatyzacja Sanyo
- klimatyzacja Clatronic
- klimatyzacja Telefunken
- klimatyzacja Oregon Scientific
- klimatyzacja Calor
- klimatyzacja Inventum
- klimatyzacja SVAN
- klimatyzacja IFB
- klimatyzacja Princess
- klimatyzacja Carson
- klimatyzacja Innoliving
- klimatyzacja Argoclima
- klimatyzacja Heller
- klimatyzacja Aermec
- klimatyzacja Comfee
- klimatyzacja Bonaire
- klimatyzacja Meaco
- klimatyzacja Kenmore
- klimatyzacja VOX
- klimatyzacja Insignia
- klimatyzacja Frilec
- klimatyzacja Element
- klimatyzacja Orima
- klimatyzacja Aspes
- klimatyzacja Hitachi
- klimatyzacja Blumfeldt
- klimatyzacja Emerson
- klimatyzacja SereneLife
- klimatyzacja Frigidaire
- klimatyzacja CyberPower
- klimatyzacja EcoFlow
- klimatyzacja RCA
- klimatyzacja Climadiff
- klimatyzacja Whynter
- klimatyzacja Ridgid
- klimatyzacja Lanaform
- klimatyzacja Electroline
- klimatyzacja Kelvinator
- klimatyzacja Sencor
- klimatyzacja Mistral
- klimatyzacja Nabo
- klimatyzacja Fuave
- klimatyzacja Kalorik
- klimatyzacja Avidsen
- klimatyzacja Suntec
- klimatyzacja Be Quiet!
- klimatyzacja Carrier
- klimatyzacja Geist
- klimatyzacja Esatto
- klimatyzacja Daewoo
- klimatyzacja Livington
- klimatyzacja Consul
- klimatyzacja Kunft
- klimatyzacja Zibro
- klimatyzacja Becken
- klimatyzacja Guzzanti
- klimatyzacja Cool-Space
- klimatyzacja KuulAire
- klimatyzacja Alpatec
- klimatyzacja Volteno
- klimatyzacja ActronAir
- klimatyzacja Tectro
- klimatyzacja Eurom
- klimatyzacja Sauber
- klimatyzacja PRIME3
- klimatyzacja Sonnenkönig
- klimatyzacja Proline
- klimatyzacja Toyotomi
- klimatyzacja Soler & Palau
- klimatyzacja Monzana
- klimatyzacja Finlux
- klimatyzacja Challenge
- klimatyzacja Bestron
- klimatyzacja Yolco
- klimatyzacja AireMax
- klimatyzacja Rotel
- klimatyzacja Profile
- klimatyzacja Columbia Vac
- klimatyzacja Airwell
- klimatyzacja Amcor
- klimatyzacja Argo
- klimatyzacja KDK
- klimatyzacja Anslut
- klimatyzacja Coolix
- klimatyzacja Tosot
- klimatyzacja Korona
- klimatyzacja Progress
- klimatyzacja Tomado
- klimatyzacja Vestel
- klimatyzacja Itho
- klimatyzacja Mabe
- klimatyzacja Logik
- klimatyzacja Profilo
- klimatyzacja Heinner
- klimatyzacja Termozeta
- klimatyzacja Eldom
- klimatyzacja Jocca
- klimatyzacja Defy
- klimatyzacja Premium
- klimatyzacja White Knight
- klimatyzacja GlobalTronics
- klimatyzacja Evolar
- klimatyzacja Kubo
- klimatyzacja Elba
- klimatyzacja Royal Sovereign
- klimatyzacja Ansonic
- klimatyzacja Malmbergs
- klimatyzacja Everglades
- klimatyzacja Heylo
- klimatyzacja ElectriQ
- klimatyzacja Listo
- klimatyzacja Daitsu
- klimatyzacja Ufesa
- klimatyzacja Milectric
- klimatyzacja Olimpia Splendid
- klimatyzacja Saunier Duval
- klimatyzacja Duux
- klimatyzacja Primo
- klimatyzacja Godrej
- klimatyzacja Maiko
- klimatyzacja Conrad
- klimatyzacja Igenix
- klimatyzacja Essentiel B
- klimatyzacja Team
- klimatyzacja Equation
- klimatyzacja Edy
- klimatyzacja Edgestar
- klimatyzacja Maxicool
- klimatyzacja Dantherm
- klimatyzacja Carrefour Home
- klimatyzacja Equator
- klimatyzacja HQ
- klimatyzacja BOSFOR
- klimatyzacja MundoClima
- klimatyzacja Proklima
- klimatyzacja Home Electric
- klimatyzacja Eco-De
- klimatyzacja Fairland
- klimatyzacja Aconatic
- klimatyzacja Duracraft
- klimatyzacja DEXP
- klimatyzacja Just Fire
- klimatyzacja Teco
- klimatyzacja Iceberg
- klimatyzacja Khind
- klimatyzacja Chigo
- klimatyzacja Hokkaido
- klimatyzacja Tarrington House
- klimatyzacja Firstline
- klimatyzacja Holland Electro
- klimatyzacja Evapolar
- klimatyzacja Orava
- klimatyzacja Elgin
- klimatyzacja Tronix
- klimatyzacja Ausclimate
- klimatyzacja Liebert
- klimatyzacja Sencys
- klimatyzacja Fronius
- klimatyzacja Avalon Bay
- klimatyzacja SMC
- klimatyzacja D-Let
- klimatyzacja Kogan
- klimatyzacja Braemar
- klimatyzacja Klimaire
- klimatyzacja SEEGER
- klimatyzacja General Electric
- klimatyzacja SPT
- klimatyzacja Simplicity
- klimatyzacja Starlyf
- klimatyzacja Aerian
- klimatyzacja Moa
- klimatyzacja Fuji Electric
- klimatyzacja Polocool
- klimatyzacja Convair
- klimatyzacja Kibernetik
- klimatyzacja Fral
- klimatyzacja Companion
- klimatyzacja Prem-i-air
- klimatyzacja Arcoaire
- klimatyzacja Céliera
- klimatyzacja Bodin
- klimatyzacja Magnavox
- klimatyzacja AFINTEK
- klimatyzacja Brivis
- klimatyzacja MRCOOL
- klimatyzacja B-Air
- klimatyzacja Trilec
- klimatyzacja Kaden
- klimatyzacja Avallon
- klimatyzacja TURBRO
- klimatyzacja House & Luft
- klimatyzacja Evapcool
- klimatyzacja Protector
- klimatyzacja Vostok
- klimatyzacja American Comfort
- klimatyzacja Ocean Breeze
- klimatyzacja Quirky
- klimatyzacja Krone
- klimatyzacja KwiKool
- klimatyzacja Big Ass Fans
- klimatyzacja Arctic King
- klimatyzacja Artrom
- klimatyzacja Senville
- klimatyzacja Climachill
- klimatyzacja Commercial Cool
- klimatyzacja Riffel
- klimatyzacja Heat Controller
- klimatyzacja Luma Comfort
- klimatyzacja Norpole
- klimatyzacja Kaco
- klimatyzacja Middle Atlantic
- klimatyzacja Goodwe
- klimatyzacja Swegon
- klimatyzacja JHS
- klimatyzacja FREONIC
- klimatyzacja ARCTIC WIND
- klimatyzacja VänEE
- klimatyzacja Mayer
- klimatyzacja Perfect Aire
- klimatyzacja Koldfront
- klimatyzacja Yamazen
- klimatyzacja Universal Blue
- klimatyzacja Symphony
- klimatyzacja Corona
- klimatyzacja Sheffield
Najnowsze instrukcje dla klimatyzacja

25 Marca 2025

18 Marca 2025

18 Marca 2025

18 Marca 2025

18 Marca 2025

18 Marca 2025

18 Marca 2025

12 Marca 2025

12 Marca 2025

12 Marca 2025