Models: F2452 (Windsor/Hamilton)
Owners &
Installation
PLEASE KEEP THESE INSTRUCTIONS FOR
FUTURE REFERENCE
Manual
April-14-2022
920-370b
WARNING:
Improper installation, adjustment, alteration, service or maintenance
can cause injury or property damage. Refer to this manual. For assis-
tance or additional information consult an authorised installer, service
agency or the distributor.
FOR YOUR SAFETY
Do not store or use petrol or other ammable vapours and liquids in
the vicinity of this or any other appliance.
Installation and service must be performed by an authorised installer
or service agency.
FREESTANDING WOOD FIRE
MODEL: Windsor MODEL: Hamilton
FPI - FIREPLACE PRODUCTS AUSTRALIA PTY LTD.
99 COLEMANS ROAD, DANDENONG SOUTH
VICTORIA 3175
Thank you for purchasing a
REGENCY FIREPLACE PRODUCT.
The pride of workmanship that goes into each of our products will give you years of trouble-free enjoyment. Should you have any questions about
your product that are not covered in this manual, please contact the in your area.REGENCY DEALER
"This wood heater has a manufacturer set minimum low burn rate that must not be altered. It is against federal regulations to
alter this setting or otherwise operate this wood heater in a manner inconsistent with operating instructions in this manual.”
Failure to follow the manual details can lead to smoke and CO emissions spilling into the home. It is recommended to have
monitors in areas that are expected to generate CO such as heater fueling areas.
"This manual describes the installation and operation of the Regency F2452 wood heater. This heater generates the best eciency when operated
using well-seasoned wood and installed in the main living areas where the majority of the chimney is within the building envelope. "This wood
heater needs periodic inspection and repair for proper operation.
It is against federal regulation to operate this wood heater in a manner inconsistent with operating instructions in this manual."
CAUTION: BURN UNTREATED WOOD ONLY. OTHER MATERIALS SUCH AS WOOD PRESERVATIVES, METAL FOILS, COAL, PLASTIC,GARBAGE, SUL-
PHUR OR OIL MAY DAMAGE THE STOVE.
"This heater is designed to burn natural wood only. Higher eciencies and lower emissions generally result when burning air dried seasoned hard-
woods, as compared to softwoods or to green or freshly cut hardwoods."
DO NOT BURN:
• Treated wood Lawn clippings or yard waste Manure or animal remains
• Coal Materials containing rubber including tires Saltwater driftwood or other previously salt
water saturated materials
• Garbage Materials containing plastic Unseasoned wood
• Cardboard Waste petroleum products , paints or paint thinners or asphalt
products
Paper products, cardboard, plywood or par-
ticle board. The prohibition against burning
these materials does not prohibit the use of
re starters made from paper, cardboard,
saw dust, wax and similar substances for
the purpose of starting a re in a wood
heater.
• Solvents Materials containing asbestos
• Colored Paper Construction or demolition debris
• Trash Tea tree or oil based woods
Burning these materials may result in release of toxic fumes or render the heater ineective and cause smoke.
The authority having jurisdiction (such as Municipal Building Department, Fire Department, Fire Prevention Bureau, etc.) should
be consulted before installation to determine the need to obtain a permit.
SAVE THESE INSTRUCTIONS
ONLY CLEAN APPLIANCE WITH A DAMP CLOTH
(NEVER WHEN UNIT IS HOT)
Do NOT USE ANY ABRASIVE CLEANERS
Copy of Data Badge 4 ......................................................
Dimensions
Unit Dimensions 5 ............................................................
Arched Door 5 .................................................................
Square Door 5 .................................................................
Outside Air Dimensions 5 ..................................................
Installation
Residential Installation 6 ...................................................
Room Air - Important 6 ....................................................
Modular Installation Options...........................................6
Stove Assembly Prior to Installation 7 ................................
Airmate Assembly 7 ..........................................................
Rear Heat Deector Assembly ........................................7
Side Shield Adjustment 7 ..................................................
Pedestal Assembly Installation - F2452 8 ...........................
Logo Installation 8 ...........................................................
Bottom Heat Shield and Legs Installation - F2452 8 ............
Wood Handle & Door Assembly - F2452 (Arched Door) 9 ....
Square Door Installation - F2452 10 ..................................
Clearance Requirements (152mm Double / Triple Skin Flue
Kits) 11 ...........................................................................
Appendices 12-13 ............................................................
Appendix 1: Triple Skin Default Flue Kit 12 .........................
Appendix 2: Statewide Heating 6141ws 13 ........................
Flue Termination Detail 14 ................................................
Brick Installation 15 .........................................................
Flue Bae & Secondary Air Tube Installation ................. 16
Fan Installation 17 ...........................................................
Stainless Steel Smoke Deector Installation ................... 18
Seasoned Firewood 19 .....................................................
Operation
Operating Instructions 19 .............................................
Draft Control 19 ...........................................................
First Fire 20 .................................................................
Fan Operation 21 .........................................................
Ash Disposal 21 ...........................................................
Ash Drawer Operating Guidelines 21 .............................
Safety Guidelines and Warnings................................21
Maintenance
Glass Replacement (Square Door) 22 ............................
Arched Door Handle Replacement 22 ............................
Glass Replacement (Arched Door) 22 ............................
Maintenance 23 ...........................................................
Creosote 23 .................................................................
Ways to Prevent and Keep Unit Free of Creosote 23 .......
Door Gasket 23 ............................................................
Glass Maintenance 23 ..................................................
Wood Storage 23 .........................................................
Secondary Air Tube Removal / Installation 24 .................
Annual Maintenance 24 ................................................
Vertical Stainless Deector Replacement ...................25
Parts
Main Assembly 26 ........................................................
Bases 28 .....................................................................
Brick Kit 29 ..................................................................
Warranty
Warranty 30 ................................................................
CAUTION: To avoid burns or wood splinters, when opening/closing the fuel
door or adding wood to the re, You should always wear appropriate pro-
tective gloves to protect your hands from the heat being emitted from this
replace.


Specyfikacje produktu

Marka: Regency
Kategoria: Podgrzewacz
Model: Hamilton F2452

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z Regency Hamilton F2452, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą