Constant
Running
Hydraulic
Pump
Installation Guide
Document Number: 87039-2
Date: March 2006
87039_2.fm Page 1 Wednesday, April 9, 2014 2:56 PM
2 CR Hydraulic Pump - Installation Guide
Important information
Drives covered
M81126 - Raymarine Constant Running Pump (Variable flow) 12V
M81128 - Raymarine Constant Running Pump (Variable flow) 24V
Safety notices
WARNING: Product installation
This equipment must be installed and operated in accordance
with the instructions contained in this handbook. Failure to do so
could result in poor product performance, personal injury and/or
damage to your boat.
Because correct performance of the boats steering is critical for
safety, we STRONGLY RECOMMEND that an Authorized Raymarine
Service Representative fits this product.
WARNING: Navigation aid
Although we have designed this product to be accurate and
reliable, many factors can affect its performance. As a result, it
should only be used as an aid to navigation and should never
replace commonsense and navigational judgement. Always
maintain a permanent watch so you can respond to situations as
they develop.
EMC installation guidelines
All Raymarine equipment and accessories are designed to the best industry
standards for use in the recreational marine environment.
Their design and manufacture conforms to the appropriate Electromagnetic
Compatibility (EMC) standards, but correct installation is required to ensure that
performance is not compromised. Although every effort has been taken to ensure
that they will perform under all conditions, it is important to understand what
factors could affect the operation of the product.
The guidelines given here describe the conditions for optimum EMC performance,
but it is recognized that it may not be possible to meet all of these conditions in all
situations. To ensure the best possible conditions for EMC performance within the
constraints imposed by any location, always ensure the maximum separation
possible between different items of electrical equipment.
For optimum EMC performance, it is recommended that wherever possible:
87039_2.fm Page 2 Wednesday, April 9, 2014 2:56 PM
3
Raymarine equipment and cables connected to it are:
At least 3 ft. (1 m) from any equipment transmitting or cables carrying radio
signals e.g. VHF radios, cables and antennas. In the case of SSB radios, the dis-
tance should be increased to 7 ft. (2 m).
More than 7 ft. (2 m) from the path of a radar beam. A radar beam can nor-
mally be assumed to spread 20 degrees above and below the radiating ele-
ment.
The equipment is supplied from a separate battery from that used for engine start.
Voltage drops below 10 V, and starter motor transients, can cause the equipment
to reset. This will not damage the equipment, but may cause the loss of some
information and may change the operating mode.
Raymarine specified cables are used. Cutting and rejoining these cables can
compromise EMC performance and must be avoided unless doing so is detailed in
the installation manual.
If a suppression ferrite is attached to a cable, this ferrite should not be removed. If
the ferrite needs to be removed during installation it must be reassembled in the
same position. Always use the ferrites supplied by Raymarine.
Connections to other equipment
If your Raymarine equipment is to be connected to other equipment using a cable
not supplied by Raymarine, a suppression ferrite MUST always be attached to the
cable near to the Raymarine unit.
Waste Electrical and Electronic Equipment Directive
The Waste Electrical and Electronic Equipment (WEEE) Directive
requires the recycling of waste electrical and electronic equipment.
Whilst the WEEE Directive does not apply to some of Raymarines
products, we support its policy and ask you to be aware of how to
dispose of this product. The crossed out wheelie bin symbol, illustrated above,
and found on our products sigifies that this product should not be disposed of in
general waste or landfill. Please contact your local dealer, national distributor or
Raymarine Technical Services for information on product disposal.
87039_2.fm Page 3 Wednesday, April 9, 2014 2:56 PM


Specyfikacje produktu

Marka: Raymarine
Kategoria: Morski
Model: M81126 Constant Running Hydraulic Pump

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z Raymarine M81126 Constant Running Hydraulic Pump, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje Morski Raymarine

Raymarine

Raymarine ES75 Instrukcja

26 Września 2024
Raymarine

Raymarine A75 Instrukcja

26 Września 2024
Raymarine

Raymarine GS195 Instrukcja

26 Września 2024
Raymarine

Raymarine A50D Instrukcja

26 Września 2024
Raymarine

Raymarine Cam100 Instrukcja

25 Września 2024
Raymarine

Raymarine i50 Instrukcja

25 Września 2024
Raymarine

Raymarine ES78 Instrukcja

25 Września 2024
Raymarine

Raymarine E165 Instrukcja

25 Września 2024
Raymarine

Raymarine i70 Instrukcja

24 Września 2024

Instrukcje Morski

Najnowsze instrukcje dla Morski

Silva

Silva S15 Instrukcja

28 Września 2024
Silva

Silva S15-N Navtex Instrukcja

28 Września 2024
IVT

IVT 8A Solar Instrukcja

28 Września 2024
Digital Yacht

Digital Yacht WL400 Instrukcja

28 Września 2024
Digital Yacht

Digital Yacht WL50 Instrukcja

28 Września 2024
Digital Yacht

Digital Yacht WL500 Instrukcja

28 Września 2024
Humminbird

Humminbird 323 Instrukcja

27 Września 2024