Instrukcja obsługi PowerPlus POWXG9535
Przeczytaj poniżej 📖 instrukcję obsługi w języku polskim dla PowerPlus POWXG9535 (7 stron) w kategorii Przepych. Ta instrukcja była pomocna dla 3 osób i została oceniona przez 2 użytkowników na średnio 4.5 gwiazdek
Strona 1/7
POWXG9535 EN
Copyright © 2 VARO NV 202 P a g e | 1www.varo.com
1 APPLICATION .................................................................................. 2
2 DESCRIPTION (FIG A) .................................................................... 2
3 PACKAGE CONTENT LIST ............................................................. 2
4 SYMBOLS ........................................................................................ 2
5 GENERAL POWER TOOL SAFETY WARNINGS .......................... 3
6 BEFORE START-UP, NOTE THE FOLLOWING! ........................... 3
7 INSTALLATION ................................................................................ 3
8 SETTING TO WORK ........................................................................ 4
8.1 Venting the pump before use ................................................................................. 4
8.2 Setting the ON/OFF operating point 4 .......................................................................
9 CLEANING AND MAINTENANCE ................................................... 4
9.1 Maintenance guidelines .......................................................................................... 5
9.2 Cleaning the impeller .............................................................................................. 5
10 TECHNICAL DATA .......................................................................... 5
11 SERVICE DEPARTMENT ................................................................ 5
12 TROUBLESHOOTING ..................................................................... 6
13 STORAGE ........................................................................................ 6
14 WARRANTY ..................................................................................... 7
15 ENVIRONMENT ............................................................................... 7
16 DECLARATION OF CONFORMITY ................................................ 8
POWXG9535 EN
Copyright © 2 VARO NV 202 P a g e | 3www.varo.com
5 GENERAL POWER TOOL SAFETY WARNINGS
Read all safety warnings and all instructions. Failure to follow all warnings and instructions
may result in electric shock, fire and/or serious injury. Save all warnings and instructions for
future reference. The term "power tool" in the warnings refers to your mains operated (corded)
power tool or battery operated (cordless) power tool.
6 BEFORE START-UP, NOTE THE FOLLOWING!
▪ The pump can be connected to any shock-proof plug which has been installed according
to regulations. The plug must have a supply voltage of 230 V ~ 50 Hz. Fuse min. 6 Amp.
Caution!
When the pump is to be used near swimming pools or garden ponds and in their area of
protection, it must be equipped with a PRCD (residual current circuit breaker) with a nominal
trip current of max. 30 mA (according to VDE 0100, part 702 and 738). The pump must not be
operated while people are in the swimming pool or in the garden pond! Please contact your
electrician!
Attention!
(Important for your own security) Before starting to run your new submersible pump, please
have the following items checked by an expert:
▪ Ground connection
▪ Zero conductor
▪ Fault current breaker switch must correspond the safety regulations of the power plants
and they must work faultlessly.
▪ The electrical connections must be protected from moisture.
▪ If there is danger of flooding, the electrical connections must be taken to higher ground.
▪ Circulation of aggress e fluids, as well as the circulation of abrasive materials must be iv
avoided at all costs.
▪ The submersible motor-driven pump must be protected from frost.
▪ The pump must be protected from running dry.
▪ Access on the part of children should also be prevented with appropriate measures.
Consistency
Your submersible pump is designed for the circulation of water with a maximum temperature
of 35° C. This pump may not be used for other fluids, especially motor fuels, cleaning fluids,
and other chemical products!
7 INSTALLATION
The submersible pump is installed as follows:
▪ In a stationary position with fixed pipeline
or
▪ in a stationary position with a flexible hose pipe.
Please note!
You should never install the pump by suspending it unsupported from its delivery pipe or
power cable. The submersible pump must be suspended from the specially provided handle or
be placed on the bottom of the shaft. To guarantee that the pump works properly, the bottom
of the shaft must be kept free of sludge and dirt of all kinds.
If the level of water sinks too far, any sludge in the shaft will dry out quickly and stop the pump
from starting up. ,Therefore it is necessary to check the submersible motor pump regularly (by
carrying out start-up tests). The floater is adjusted in a way that the pump can immediately be
started
Note!
The pump shaft should have minimum dimensions of 40 x 40 x 50 cm, so that the floating
switch can move freely.
POWXG9535 EN
Copyright © 2 VARO NV 202 P a g e | 4www.varo.com
Mains supply
Your new submersible pump is equipped with a shock-proof plug according to regulations. The
pump is designed to be connected to a 230V - 50 Hz earthed socket. Make sure that the
socket is sufficiently secured (min. 6 Amp.) and is in excellent condition. Introduce the plug
into the socket and the pump is ready to go.
Important Note!
If the mains cable or plug suffers any damage from external action, repairs to the cable should
be serviced by a qualified specialist using only standard spare parts. This will ensure that it
meets the required safety standards.
8 SETTING TO WORK
After having read these instructions carefully, you can set your pump to work, reconsidering
the following:
▪ Check if the pump rests on the ground of the shaft.
▪ Check of pressure cord has been attached properly.
▪ Check if electrical connection is 230 V - 50 Hz.
▪ Check if socket is in good condition.
▪ Make sure that water and humidity can never come to the mains supply.
▪ Avoid pump running dry.
8.1 Venting the pump before use
▪ Always ensure that the pump is vented properly before commissioning the pump. Possibly
tilting back and forth several times until no more air bubbles appear, wait at least 15
seconds before the pump to start.
8.2 Setting the ON/OFF operating point
The ON and OFF operating point of the float switch can be set by adjusting the float switch in
its latching holder.
Before you put the pump into operation, please check the following:
▪ The float switch must be installed so that the level of the ON operating point and the level
of the OFF operating point can be reached easily and with little force. To check this, place
the pump in a vessel filled with water, raise the float switch carefully by hand and then
lower it again. As you do so, note whether the pump switches on and off.
▪ Make sure that the distance between the float switch head and the latching holder is not
too small. Proper operation is not guaranteed if the gap is too small.
▪ When you set the float switch, make sure that it does not touch the base before the pump
switches off. Caution! Risk of dry-running.
This appliance cannot be used by children or people who are physically, mentally or
developmentally impaired, or people who lack experience or knowledge, except in case
these people receive instruction from a person responsible for their safety, a
supervisor, or by studying the preceding instructions concerning use of this appliance.
9 CLEANING AND MAINTENANCE
Attention !Before performing any work on the equipment, pull the power
plug.
Never use solvents such as petrol, alcohol, ammonia water, etc. These
solvents may damage the plastic parts.
Specyfikacje produktu
Marka: | PowerPlus |
Kategoria: | Przepych |
Model: | POWXG9535 |
Potrzebujesz pomocy?
Jeśli potrzebujesz pomocy z PowerPlus POWXG9535, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą
Instrukcje Przepych PowerPlus
6 Października 2024
11 Września 2024
7 Września 2024
7 Września 2024
5 Września 2024
4 Września 2024
4 Września 2024
3 Września 2024
31 Sierpnia 2024
31 Sierpnia 2024
Instrukcje Przepych
- Przepych Worx
- Przepych Milwaukee
- Przepych SilverCrest
- Przepych Simpson
- Przepych Ultimate Speed
- Przepych Parkside
- Przepych Ferroli
- Przepych Toolcraft
- Przepych Kärcher
- Przepych Bestway
- Przepych Scheppach
- Przepych Ribimex
- Przepych Quigg
- Przepych Hazet
- Przepych Siemens
- Przepych Gardena
- Przepych Einhell
- Przepych Hyundai
- Przepych Husqvarna
- Przepych Makita
- Przepych Ozito
- Przepych Testo
- Przepych Fuxtec
- Przepych Fiap
- Przepych RYOBI
- Przepych Polaris
- Przepych Biltema
- Przepych Hozelock
- Przepych Crivit
- Przepych Osram
- Przepych AL-KO
- Przepych Danfoss
- Przepych Güde
- Przepych Panduit
- Przepych Vaillant
- Przepych JANDY
- Przepych Zipper
- Przepych Grundfos
- Przepych Fluke
- Przepych Bartscher
- Przepych Lavorwash
- Przepych Fluval
- Przepych Neptun
- Przepych Westfalia
- Przepych Hayward
- Przepych Ergotools Pattfield
- Przepych Lezyne
- Przepych Eheim
- Przepych Zehnder Pumpen
- Przepych Oase
- Przepych Michelin
- Przepych Aerotec
- Przepych Blumfeldt
- Przepych Fieldmann
- Przepych Technaxx
- Przepych Gardenline
- Przepych Alpha Tools
- Przepych Vonroc
- Przepych Powerfix
- Przepych OKAY
- Przepych Metabo
- Przepych Ubbink
- Przepych AstralPool
- Przepych Gre
- Przepych Eurom
- Przepych Enermax
- Przepych Blackburn
- Przepych Nefit
- Przepych Vetus
- Przepych Sicce
- Przepych Outwell
- Przepych Sun Joe
- Przepych Tacklife
- Przepych SKS
- Przepych Nibe
- Przepych Melinera
- Przepych Sanibroyeur
- Przepych Zodiac
- Przepych Topeak
- Przepych Bulex
- Przepych For_Q
- Przepych Abac
- Przepych Waldbeck
- Przepych Cannondale
- Przepych Coleman
- Przepych Maruyama
- Przepych Jabsco
- Przepych Eufab
- Przepych Pontec
- Przepych Batavia
- Przepych ESPA
- Przepych T.I.P.
- Przepych Pedrollo
- Przepych Velda
- Przepych Vivaria
- Przepych Plantiflor
- Przepych Verto
- Przepych Little Giant
- Przepych Wetelux
- Przepych Germania
- Przepych Anova
- Przepych DAB
- Przepych Esotec
- Przepych Wayne
- Przepych Rule
- Przepych Elpumps
- Przepych Hollex
- Przepych B-Air
- Przepych Baracuda
- Przepych Lifan
- Przepych Liberty Pumps
- Przepych BluGarda
- Przepych Madimack
- Przepych Sauermann
- Przepych Eco-Flo
- Przepych Nowax
- Przepych Zoeller
- Przepych Superior Pump
- Przepych SHURflo
- Przepych EvoHeat
- Przepych MSW
- Przepych Barwig
- Przepych Ebara
- Przepych Perlick
- Przepych Basement Watchdog
- Przepych Zéfal
- Przepych Comet
- Przepych Heissner
- Przepych OSIP
- Przepych Franklin Electric
Najnowsze instrukcje dla Przepych
11 Stycznia 2025
11 Stycznia 2025
11 Stycznia 2025
11 Stycznia 2025
4 Stycznia 2025
4 Stycznia 2025
4 Stycznia 2025
2 Stycznia 2025
1 Stycznia 2025
1 Stycznia 2025