Instrukcja obsługi Planet ISW-504PT
Planet
przełącznik
ISW-504PT
Przeczytaj poniżej 📖 instrukcję obsługi w języku polskim dla Planet ISW-504PT (2 stron) w kategorii przełącznik. Ta instrukcja była pomocna dla 11 osób i została oceniona przez 2 użytkowników na średnio 4.5 gwiazdek
Strona 1/2
- 1 -
- 2 -
- 3 -
- 4 -
- 5 -
- 6 -
- 7 -
- 8 -
1. Package Contents
Thank you for purchasing PLANET 5-Port Industrial Ethernet
Switch with 4-Port PoE, ISW-504PT/ISW-514PTF. The interfaces
of these models are shown below:
Model Name 10/100Mbps RJ45
Ports 100FX SFP Slots PoE Ports
ISW-504PT 5 - 4
ISW-514PTF 4 1 4
In the following section, the term “Industrial PoE+ Switch”
means the ISW-504PT/ISW-514PTF.
2. Hardware Introduction
2.1 Switch Front Panel
P1 P2 Fault
120W
PoE Usage
90W
60W
30W
4
5
3
2
1
LNK ACT
PoE-in-Use
挖孔
挖孔
10/100TX
LNK/
ACT
5
DIP
1~4
VLAN
ON
Extended
OFF
Standard
Standard
1 2 3 4 5
ONDIP
3
1
4
5
3
2
1
LNK ACT
PoE-in-Use
挖孔
P1 P2 Fault
100FX
5
DIP
1~4
VLAN
ON
Extended
OFF
Standard
Standard
120W
PoE Usage
90W
60W
30W
1 2 3 4 5
ONDIP
2
Figure 2-1:
ISW-504PT front panel
Figure 2-2:
ISW-514PTF front panel
1. Fast Ethernet TP Interfaces
10/100BASE-TX copper, RJ45 twisted-pair: Up to 100 meters.
2.3 Switch Upper Panel
The upper panel of the Industrial PoE+ Switch consists of one
terminal block connector within two DC power inputs.
Figure 2-3 shows the upper panel of the Industrial PoE+ Switch.
Input DC 12~48V
Fault max.
load 1A@24V
FaultDC1 DC2
1 2 3 4 5 6
Figure 2-3: Industrial PoE+ Switch Upper Panel
2.4 Wiring the Power Inputs
The 6-contact terminal block connector on the top panel of
Industrial PoE+ Switch is used for two DC redundant power
inputs. Please follow the steps below to insert the power wire.
When performing any of the procedures like
inserting the wires or tightening the wire-clamp
screws, make sure the power is OFF to prevent
from getting an electric shock.
2.2 LED Indicators
System
LED Color Function
P1 Green Lights: indicates power 1 has power.
P2 Green Lights: indicates power 2 has power.
FAULT Red Lights: indicates either power 1 or power 2
has no power.
30W Amber
O: indicates the PoE usage is less than
14W.
Blinks: indicates that the PoE usage is
around 15W to 29W.
Lights: indicates the PoE usage is around/
over 30W.
60W Amber
Blinks: indicates that the PoE usage is
around 45W to 59W.
Lights: indicates the PoE usage is around/
over 60W.
90W Amber
Blinks: indicates that the PoE usage is
around 75W to 89W.
Lights: indicates the PoE usage is around/
over 90W.
120W Amber
Blinks: indicates that the PoE usage is
around 100W to 119W.
Lights: indicates the PoE usage is at the
maximum.
Open the box of the Industrial PoE+ Switch and carefully
unpack it. The box should contain the following items:
Industrial PoE+ Switch x 1 User’s Manual x 1
Dust Cap x 5 Wall-mount Kit x 1
If any of these are missing or damaged, please contact your
dealer immediately.
2. 100BASE-FX SFP Slot (ISW-514PTF)
100BASE-FX mini-GBIC slot, SFP (small form-factor plug-
gable) transceiver module: From 2 kilometers (multi-mode
ber) to 20/40/60 kilometers (single-mode ber).
3. DIP Switch
The Industrial PoE+ Switch provides one DIP switch for
Standard, VLAN and Extended mode selections. The
detailed descriptions are shown in the following table.
DIP Switch
Mode Function
Standard Switches 1 to 5 are o.
This mode makes the Industrial PoE+ Switch
operate as a general switch and all PoE ports
operate at 10/100Mbps auto-negotiation.
VLAN
Switch 5 is on.
This mode makes the Industrial PoE+ Switch
operate as a V andLAN isolation switch
1. Ports 1 to 4 will isolate respectively.
2. Ports 1 to 4 can only communicate with Port 5.
Note
After adjusting VLAN DIP switch,
reboot the Industrial PoE+ Switch to
make the change take effect.
Extended Any of switches 1 to 4 is on.
This mode makes the Industrial PoE+ Switch
operate on a per-port basis at 10Mbps full duplex
operation but can support IEEE 802.3af PoE power
output over a distance of up to 250 meters
overcoming the 100m limit on Ethernet UTP cable.
Per 802.3at PoE+ 10/100BASE-TX Interface (Port 1
to Port 4)
LED Color Function
LNK/
ACT Green
Lights: indicates the link through that port
is successfully established at 10Mbps or
100Mbps.
Blinking: indicates that the switch is
actively sending or receiving data over that
port.
PoE-
in-Use Amber
Lights: indicates the port is providing DC
in-line power.
O: indicates the connected device is not a
PoE powered device (PD).
Per 10/100BASE-TX Interface (Port 5 of ISW-504PT)
LED Color Function
LNK/
ACT Green
Lights: indicates the link through that port is
successfully established at 10/100Mbps.
Blinking: indicates that the switch is actively
sending or receiving data over that port.
Per 100FX SFP Slot (Port 5 of ISW-514PTF)
LED Color Function
LNK/
ACT Green
Lights: indicates the link through that port is
successfully established at 100Mbps.
Blinks: indicates that the switch is actively
sending or receiving data over that port.
1. The DC power input range is . Please insert 12V ~ 48V DC
positive and negative DC power wires into contacts 1 and 2
for POWER 1, or 5 and 6 for POWER 2.
Input DC 12~48V
Fault max.
load 1A@24V
FaultDC1 DC2
1 2 3 4 5 6
DC Input Max. PoE Budget
12V 60W
24V 90W
48V 120W
Note
To avoid damage, please use the Industrial PoE+
Switch under its specification.
- 9 -
- 10 -
- 11 -
- 12 - - 13 - - 14 -
2. Tighten the wire-clamp screws for preventing the wires from
loosening.
1 2 3 4 5 6
Power 1 Fault Power 2
+ - + -
Note
The wire gauge for the terminal block should be in
the range between 12 and 24 AWG.
2.5 Wiring the Fault Alarm Contact
The fault alarm contacts are in the middle of the terminal block
connector as the picture shows below. Inserting the wires,
the Industrial PoE+ Switch will detect the fault status of the
power failure and then forms an open circuit. The following
illustration shows an application example for wiring the fault
alarm contacts.
3. Installation
This section describes the functionalities of the Industrial PoE+
Switch’s components and guides you to installing it on the
DIN-rail and wall. Basic knowledge of networking is assumed.
Please read this chapter completely before continuing.
Note
The installation procedures of the ISW-504PT and
ISW-514PTF are the same as they are shown
below.
3.1 DIN-rail Mounting Installation
1 2 3 4 5 6
Fault Alarm Contacts
The Fault Alarm Contacts are
energized (CLOSE) for normal
operation and will OPEN when
failure occurs
Fault
Insert the wires into the fault alarm contacts
Note
1. The wire gauge for the terminal block should be
in the range between 12 and 24 AWG.
2. Alarm relay circuit accepts up to 24V, max. 1A
currents.
2.6 Grounding the Device
Uses MUST complete grounding wired with the device;
otherwise, a sudden lightning could cause fatal damage to the
device. EMD (Lightning) DAMAGE IS NOT CONVERED UNDER
WARRANTY.
3.2 Wall-mount Plate Mounting
3.3 Side Wall-mount Plate Mounting
4. Troubleshooting
This chapter contains information to help you solve issues. If
the Industrial PoE+ Switch is not functioning properly, make
sure the Industrial PoE+ Switch was set up according to
instructions in this manual.
What is the operating temperature of the device?
Solution:
The operating temperature is from -40 to 75 degrees C.
What is the IP code of the device?
Solution:
The device has a rugged IP40 metal housing
Per port LED is lit, but the trac is irregular
Solution:
Check whether the attached device is not set to dedicated full
duplex. Some devices use a physical or software switch to
change duplex modes. Auto-negotiation may not recognize this
type of full-duplex setting.
Why the Industrial PoE+ Switch doesn’t connect to
the network
Solution:
Check each port LED on the Industrial PoE+ Switch. Try
another port on the Industrial PoE+ Switch. Make sure the
cable is installed properly and the right type. Turn o the
power. After a while, turn on the power again.
I connected a PoE powered device to the Industrial
POE+ Switch, why it could not be powered on
Solution:
1. Please check the cable type of the connection from
Industrial POE+ Switch (port 1 to port 4) to the other
end. The cable should be an 8-wire UTP, Category 5e
or above, EIA568 cable within 100 meters. A cable with
only 4-wire, short loop or over 100 meters will aect the
power supply.
2. Please check and assure the PoE powered device is fully
complied with IEEE 802.3at standard.
5. Customer Support
Thank you for purchasing PLANET products. You can browse
our online FAQ resource at the PLANET Web site rst to
check if it could solve your issue. If you need more support
information, please contact PLANET support team.
PLANET online FAQs:
https://www.planet.com.tw/en/support/
faq?method=category&c1=3
Support team mail address:
support@planet.com.tw
Specyfikacje produktu
Marka: | Planet |
Kategoria: | przełącznik |
Model: | ISW-504PT |
Kolor produktu: | Czarny |
Materiał obudowy: | Metal |
Wysokość produktu: | 135 mm |
Szerokość produktu: | 50 mm |
Głębokość produktu: | 85.1 mm |
Waga produktu: | 596 g |
Certyfikaty: | FCC, CE |
Standardy komunikacyjne: | IEEE 802.3af, IEEE 802.3u, IEEE 802.3x |
Pełny dupleks: | Tak |
Obsługa PoE: | Tak |
Zakres temperatur (eksploatacja): | -40 - 75 °C |
Zakres wilgotności względnej: | 5 - 95 % |
Kod zharmonizowanego systemu (HS): | 85176990 |
Diody LED: | Tak |
Zakres temperatur (przechowywanie): | -40 - 85 °C |
Dopuszczalna wilgotność względna: | 5 - 95 % |
Stopień ochrony IP: | IP30 |
Możliwości montowania w stelażu: | Nie |
Typ przełącznika: | Nie zarządzany |
Podstawowe przełączanie RJ-45 Liczba portów Ethernet: | 5 |
Podstawowe przełączania Ethernet RJ-45 porty typ: | Fast Ethernet (10/100) |
Obsługa 10G: | Nie |
Wielkość tabeli adresów: | 1024 wejścia |
Przepustowość rutowania/przełączania: | 1 Gbit/s |
Produkt stackowalny: | Tak |
Montaż naścienny / rzutowanie na sufit: | Tak |
Podpora kontroli przepływu: | Tak |
Przełącznik wielowarstwowy: | L2 |
Zasilacz dołączony: | Nie |
Automatyczne MDI/MDI-X: | Tak |
Store-and-forward: | Tak |
Montaż DIN na szynie: | Tak |
Wspierany auto-learning adresów MAC: | Tak |
Wspierany auto-aging adresów MAC: | Tak |
Obsługa zasilania zapasowego (RPS): | Tak |
Auto-Negocjacja: | Tak |
Funkcje ochrony zasilania: | Krótkie spięcie |
Obsługiwane typy kabli: | Cat5, Cat5e, Cat6 |
Ilość portów Fast Ethernet (PoE): | 4 |
Przepustowość: | 0.74 Mpps |
Zasilanie przez Ethernet (PoE) zasilanie na port: | 15.4 W |
Potrzebujesz pomocy?
Jeśli potrzebujesz pomocy z Planet ISW-504PT, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą
Instrukcje przełącznik Planet
5 Października 2024
5 Października 2024
5 Października 2024
3 Października 2024
3 Października 2024
3 Października 2024
3 Października 2024
3 Października 2024
3 Października 2024
3 Października 2024
Instrukcje przełącznik
- przełącznik Yamaha
- przełącznik Tenda
- przełącznik TP-Link
- przełącznik Philips
- przełącznik SilverCrest
- przełącznik Hikvision
- przełącznik IPGARD
- przełącznik Toolcraft
- przełącznik StarTech.com
- przełącznik Theben
- przełącznik Crestron
- przełącznik Behringer
- przełącznik Nedis
- przełącznik Nexa
- przełącznik Boss
- przełącznik TRENDnet
- przełącznik Tesla
- przełącznik D-Link
- przełącznik ATen
- przełącznik Metra
- przełącznik APC
- przełącznik Eberle
- przełącznik HP
- przełącznik Honeywell
- przełącznik Manhattan
- przełącznik Tripp Lite
- przełącznik Mikrotik
- przełącznik Mercury
- przełącznik ORNO
- przełącznik Alpine
- przełącznik Chamberlain
- przełącznik Paladin
- przełącznik Lindy
- przełącznik ZyXEL
- przełącznik LogiLink
- przełącznik Linksys
- przełącznik Digitus
- przełącznik Vimar
- przełącznik Dahua Technology
- przełącznik Schneider
- przełącznik Renkforce
- przełącznik BaseTech
- przełącznik Perel
- przełącznik Trotec
- przełącznik Adder
- przełącznik Ansmann
- przełącznik Netgear
- przełącznik Velleman
- przełącznik Homematic IP
- przełącznik DataVideo
- przełącznik Totolink
- przełącznik Intertechno
- przełącznik Black Box
- przełącznik Victron Energy
- przełącznik Delta Dore
- przełącznik Pyle
- przełącznik Lancom
- przełącznik Adviti
- przełącznik Iogear
- przełącznik Intellinet
- przełącznik Setti+
- przełącznik Shelly
- przełącznik Edimax
- przełącznik EnGenius
- przełącznik SPC
- przełącznik Blustream
- przełącznik LevelOne
- przełącznik Vivolink
- przełącznik Suevia
- przełącznik Abus
- przełącznik Omnitronic
- przełącznik Elro
- przełącznik Hama
- przełącznik Marmitek
- przełącznik Ubiquiti Networks
- przełącznik Smart-AVI
- przełącznik Goobay
- przełącznik Kaiser
- przełącznik Equip
- przełącznik Kemo
- przełącznik Juniper
- przełącznik Cudy
- przełącznik QNAP
- przełącznik Micro Connect
- przełącznik Hager
- przełącznik Elation
- przełącznik Rex
- przełącznik Emerson
- przełącznik Ernitec
- przełącznik Vemer
- przełącznik CyberPower
- przełącznik Electro Harmonix
- przełącznik Atlona
- przełącznik Fibaro
- przełącznik Gefen
- przełącznik SEADA
- przełącznik Vivanco
- przełącznik Grandstream
- przełącznik Powerfix
- przełącznik Alecto
- przełącznik Kathrein
- przełącznik JUNG
- przełącznik Monacor
- przełącznik H-Tronic
- przełącznik EVE
- przełącznik Sygonix
- przełącznik Kopp
- przełącznik Belkin
- przełącznik Generac
- przełącznik Kramer
- przełącznik KanexPro
- przełącznik BZBGear
- przełącznik RGBlink
- przełącznik Raritan
- przełącznik AMX
- przełącznik Profile
- przełącznik Intermatic
- przełącznik Flamingo
- przełącznik Brennenstuhl
- przełącznik KlikaanKlikuit
- przełącznik Ei Electronics
- przełącznik Sylvania
- przełącznik Tork
- przełącznik Techly
- przełącznik Matrox
- przełącznik Steren
- przełącznik AV:link
- przełącznik Audiovox
- przełącznik Merten
- przełącznik Chacon
- przełącznik Konig
- przełącznik UPM
- przełącznik Finder
- przełącznik Grasslin
- przełącznik Gira
- przełącznik WHALE
- przełącznik PAC
- przełącznik Wentronic
- przełącznik Wago
- przełącznik Lanberg
- przełącznik Monoprice
- przełącznik Nous
- przełącznik Tiptel
- przełącznik OSD Audio
- przełącznik Berker
- przełącznik Provision ISR
- przełącznik CSL
- przełącznik PCE
- przełącznik SIIG
- przełącznik Advantech
- przełącznik Extron
- przełącznik Avocent
- przełącznik Heitronic
- przełącznik Ebode
- przełącznik Robbe
- przełącznik B-tech
- przełącznik GAO
- przełącznik Legrand
- przełącznik Kraus & Naimer
- przełącznik Ecler
- przełącznik Inverto
- przełącznik Triax
- przełącznik Rule
- przełącznik CYP
- przełącznik Phoenix Contact
- przełącznik Seuthe
- przełącznik Maclean Energy
- przełącznik SmartAVI
- przełącznik SEC24
- przełącznik Cooking Performance Group
- przełącznik Flic
- przełącznik IB Connect
- przełącznik Liberty
- przełącznik SunBriteTV
- przełącznik Hamlet
- przełącznik Noark
- przełącznik Cambium Networks
- przełącznik 2USB
- przełącznik Roline
- przełącznik KVM-TEC
- przełącznik STI
- przełącznik Epiphan
- przełącznik Mach Power
- przełącznik Axing
- przełącznik ConnectPro
- przełącznik Atlantis Land
- przełącznik GEV
- przełącznik Pizzato Elettrica
- przełącznik Baco
- przełącznik Doepke
- przełącznik Comet
- przełącznik PureLink
Najnowsze instrukcje dla przełącznik
15 Października 2024
14 Października 2024
11 Października 2024
9 Października 2024
9 Października 2024
9 Października 2024
9 Października 2024
9 Października 2024
9 Października 2024
9 Października 2024