1. Package Contents
Your GT-805A-PD carton should contain the following items:
The Gigabit Ethernet PoE PD Media
Converter x 1 Users Manual x 1
If any item is missing or damaged, please consult the dealer
from whom you purchased your Gigabit Ethernet PoE PD Media
converter.
Note
The GT-805A-PD comes with one vacant SFP
module slot. The mini GBIC SFP module is not
bundled in the package.
Mechanical
DIP switch for LFP function (Disable/Enable) setting
LED indicators for easy network diagnostics
Wall mounting or DIN-rail installation
Compact in size, easy installation
Two power input designs (IEEE 802.3af/at/bt 48V~54V DC
in-line power or optional 5V DC input)
Compact size for working with PLANET MC family media
chassis (MC-700/MC-1500/MC-1500R/MC-1500R48)
3.3 Rear View
The rear panel of the Gigabit Ethernet PoE PD media converter
comes with one DC jack, which accepts input power of 5V DC
2A.
5V DC
Figure 2: GT-805A-PD Rear View
Power
Notice
The default package of Gigabit Ethernet PoE PD
media converter does not include DC 5V power
adapter. If you need this DC 5V power adapter,
please contact your local dealer or distributor for
more assistance.
3.2 LED Indication
System
LED Color Function
PWR Green
Lit To indicate that the Gigabit Ethernet
PoE PD media converter has power.
O To indicate that the power is not
detected.
100/1000BASE-X SFP Slot
LED Color Function
Fiber
LNK/
ACT
Green
Lit To indicate the link through ber port
is successfully established.
Blink To indicate the ber port is actively
sending or receiving data.
O To indicate that the ber optic port is
linked down.
2. Product Features
Physical Port
Media conversion between 10/100/1000BASE-T and
100BASE-FX/1000BASE-SX/LX
TP Port supports 802.3af/at/bt PoE 48V-54V DC in-line-
power
TP port supports 10/100/1000BASE-T auto-negotiation and
auto-MDI/MDI-X.
Fiber media allows
- Multi-mode ber using LC connector
- Single-mode ber using LC connector
Power over Ethernet
Compatible with IEEE 802.3bt Power over Ethernet plus
plus end-span + mid-span PSE
Compatible with IEEE 802.3at Power over Ethernet plus
end-span/mid-span PSE
Backward compatible with IEEE 802.3af Power over
Ethernet
Layer 2 Features
Store-and-Forward mechanism
Non-blocking full wire-speed forwarding rate
IEEE 802.1Q Tag VLAN transparent, multicast pass
through
9K jumbo frame
IEEE 802.3x full-duplex and half-duplex back-pressure
ow control to eliminate the loss of packets
3. Hardware Description
3.1 Front View
There are one RJ45 twisted-pair jack (auto-MDI/MDI-X) with
one “PoE In LED indicator, one 100/1000X SFP ber-optic
slot, four LED indicators and one DIP switch for Link-Fault
Passthrough (LFP) feature.
When the DIP switch is turned on, the LLCF and LLR are
activated.
ACT
LNK
100/1000X
10/100/1000T
PoE In
PWR 1000
LFP
OFF
ON
TPFiber
LNK/ACT
Figure 1: GT-805A-PD Front View
Power
Notice
The Gigabit Ethernet PoE PD media converter
provides two power input systems, IEEE 802.3af/
at/bt 48V~54V DC in-line power via 10/100/1000T
RJ45 port or optional 5V DC input via DC jack
on the rear panel.
10/100/1000BASE-T Port
LED Color Function
LNK/
ACT Green
Lit To indicate the link through TP port is
successfully established.
Blink To indicate the port is actively
sending or receiving data.
O To indicate that the copper port is
linked down.
1000
LNK/
ACT
Green
Lit To indicate that the copper port is
operating at 1000Mbps.
Blink
To indicate the port is actively
sending or receiving data at
1000Mbps.
O
To indicate that the copper port
is linked down or operating at
10/100Mbps.
PoE
In Amber
Lit To indicate the RJ45 port is receiving
the PoE power.
O
To indicate the connected device is
not a PoE power sourcing equipment
(PSE).
3.4 Power Information
The power jack of Gigabit Ethernet PoE PD media converter
measures 2.5mm in the central post and requires +5VDC
power input. It conforms to the bundled AC-DC adapter and
PLANETs media chassis. Should you have the issue of power
connection, please contact your local sales representative.
2.5mm
DC Receptacle 2.5mm
+5V for each slot
DC receptacle is 2.5mm wide that conforms to the Gigabit
Ethernet PoE PD media converter’s 2.5mm DC jack's
central post. Do not install any improper unit.
- 9 -
- 10 -
- 11 -
- 12 - - 13 - - 14 -
4. Link Fault Pass-through (LFP)
It includes the Link Fault Passthrough (LFP) function and the
DIP switch. The LFP function includes the Link Loss Carry
Forward (LLCF) and Link Loss Return (LLR). LLCF and LLR can
immediately alert administrators the issue of the link media
and provide ecient solution to monitor the network. The DIP
Switch will disable or enable the LFP function.
LLCF means when a device is connected to the converter and
the TP line loses the link, the converters ber will disconnect
transmission link. LLR (Link Loss Return) means when a device
is connected to the converter and the ber line loses the link,
the converters ber will disconnect transmission link.
Note
LFP function is ON by default setting. If you
are familiar with the network installation and
for diagnostic purpose (i.e. check which end
is broken), you can turn it off and reset the
converter to make it take effect. Otherwise, please
keep it in the default position.
Step 2: Connect a standard Cat5e/6 UTP cable from power
source equipment , such as PoE switch, PoE (PSE)
injector hub and single port PoE injector, to the PoE
IN port of the GT-805A-PD.
6. Cable Connection Parameter
The wiring details are shown below:
Duplex Connection Limitation (max.)
Twisted Pair
Half/Full Node to Node
Node to Switch/Hub 100 meters
Fiber Optic Cables:
Standard
(Wavelength)
100BASE-FX
(1310nm)
1000BASE-SX
(850nm)
1000BASE-LX
(1310nm)
Fiber Type & Cable
Specications
Multi-mode 50/125μm or 62.5/125μm
Single-mode 9/12m
5. Installation
5.1 Before Installation
The GT-805A-PD is installed with the PSE (power source
equipment); it is powered by PSE and forwards the Ethernet
data to the remote media converter. The GT-805A-PD doesn’t
require an external power supply and it can be installed easily
by just plug and play without aecting the data transmission
performance.
Note
1. To provide you with better PoE power and data
extension quality, we strongly recommend that
you use when installing the Solid UTP Cable”
GT-805A-PD.
2. The GT-805A-PD can be installed with a third-
party device if the device complies with IEEE
802.3af/at/bt standard.
5.2 Connecting GT-805A-PD to Power Source
Equipment (PSE)
This section describes how to install GT-805A-PD and make
connection to it. Please read the following topics and perform
the procedures in the order being presented.
The “RJ45 PoE IN port functions as "PoE (Data and
Power) input".
Step 1: Slide in the SFP transceiver module and connect ber
cable from the GT-805A-PD to the ber network.
7.ProductSpecications
Model GT-805A-PD
Hardware Specications
Copper Port 10/100/1000BASE-T Ethernet TP RJ45
port (auto-MDI/MDI-X) twisted pair
Fiber Port 100/1000BASE-X
Fiber Port Type
(connector) SFP (LC)
Copper Maximum
Distance 100m
Fiber Maximum
Distance Vary by SFP Transceiver
LED Indicator
System: Power x 1 (Green)
TP LINK/ACT, 1000 LINK/ACT (Green).
PoE In (Amber)
Fiber LINK/ACT (Green)
DIP Switch LFP function (Disable/Enable) setting
Power
Consumption 2 watts/6.8 BTU (maximum)
Power
Requirements
IEEE 802.3af/at/bt PoE 48V-54V DC
in-line-power or optional DC 5V/2A
external power adapter
(Not included in standard package)
Dimensions
(W x D x H) 70 x 94 x 26 mm
Weight 186g
Converter Specications
Speed
Twisted-pair:
10/20Mbps for half/full duplex
100/200Mbps for half/full duplex
2000Mbps for full duplex
Fiber-optic:
200Mbps for full duplex
2000Mbps for full duplex
Network Cables
Twisted-pair:
10BASE-T: 2-pair UTP Cat. 3, 4, 5, up to
100m
100BASE-TX: 2-pair UTP Cat. 5, up to
100m
1000BASE-T: 4-pair STP Cat. 5, up to
100m
Fiber-optic Cable
1000BASE-SX:
50/12m or 62.5/12m multi-mode
ber cable, up to 220/550m/2km.
1000BASE-LX:
9/125μm single-mode cable, providing
long distance for 2/10/20/40/80/120km
(vary on SFP module)
100BASE-FX:
50/12m or 62.5/12m multi-mode
ber cable for up to 2km
(vary on SFP module)
9/125μm single-mode cable for
20/40/60/120km (vary on SFP module)
Jumbo Packet Size 9K
Standard Conformance
Standards
Compliance
IEEE 802.3 10BASE-T
IEEE 802.3u 100BASE-TX/100BASE-FX
IEEE 802.3ab 1000BASE-T
IEEE 802.3z 1000BASE-SX/LX
IEEE 802.3x full-duplex and half-duplex
back-pressure ow control to eliminate
packet loss
IEEE 802.3af Power over Ethernet
IEEE 802.3at Power over Ethernet Plus
IEEE 802.3bt 4-pair Power over Ethernet
Plus Plus (Type 3)
IEEE 802.3bt 4-pair Power over Ethernet
Plus Plus (Type 4)
Regulatory
Compliance FCC Part 15 Class A, CE
Environment
Operating
Temperature 0 ~ 50 degrees C
Storage
Temperature -10 ~ 70 degrees C
Operating
Humidity
5 ~ 95%, relative humidity,
non-condensing
Storage Humidity 5 ~ 95%, relative humidity,
non-condensing


Specyfikacje produktu

Marka: Planet
Kategoria: Niesklasyfikowane
Model: GT-805A-PD

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z Planet GT-805A-PD, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje Niesklasyfikowane Planet

Planet

Planet LS100-SMK Instrukcja

9 Października 2024
Planet

Planet IGS-1000-4UP2X Instrukcja

9 Października 2024
Planet

Planet NMS-AIoT Instrukcja

9 Października 2024
Planet

Planet NMS-ST Instrukcja

9 Października 2024
Planet

Planet IGS-R4215-24T4X Instrukcja

5 Października 2024
Planet

Planet IXT-900-2X1UP Instrukcja

4 Października 2024
Planet

Planet AVS-4210-24HP4X Instrukcja

4 Października 2024
Planet

Planet TSN-5225-4T Instrukcja

4 Października 2024
Planet

Planet MGB-LX Instrukcja

4 Października 2024
Planet

Planet ISW-514PTF Instrukcja

3 Października 2024

Instrukcje Niesklasyfikowane

Najnowsze instrukcje dla Niesklasyfikowane

Stihl

Stihl HT 70 Instrukcja

15 Października 2024
Ernesto

Ernesto H14270 Instrukcja

15 Października 2024
Uniden

Uniden BT MIC KIT Instrukcja

15 Października 2024
Vaude

Vaude Omnis Bike 26 Instrukcja

15 Października 2024
ART

ART ProChannel II Instrukcja

15 Października 2024
Aukey

Aukey DR02J Instrukcja

15 Października 2024
Master Lock

Master Lock 653EURD Instrukcja

15 Października 2024
Roland

Roland FR-18 Diatonic Instrukcja

15 Października 2024