Instrukcja obsługi Planet GT-1205A


Przeczytaj poniżej 📖 instrukcję obsługi w języku polskim dla Planet GT-1205A (2 stron) w kategorii Niesklasyfikowane. Ta instrukcja była pomocna dla 6 osób i została oceniona przez 2 użytkowników na średnio 4.5 gwiazdek

Strona 1/2
- 1 -
- 2 -
- 3 -
- 4 -
- 5 -
- 6 -
- 7 -
- 8 -
1. Package Contents
Thank you for purchasing PLANET 1-Port 10/100/1000BASE-T
to 2-Port 100/1000BASE-X Media Converter, GT-1205A.
Open the box of the GT-1205A and carefully unpack it. The box
should contain the following items:
Gigabit Media Converter x 1 User's Manual x 1
AC-DC Adapter (Output: 5V DC, 2A max.) x 1
If any item is missing or damaged, please consult the dealer
from whom you purchased your GT-1205A.
Note
The GT-1205A comes with one vacant SFP module
slot. The mini GBIC SFP module is not bundled
with in the package.
Compact in size, easy installation
Co-works with PLANETs 10”/19” Media Converter Chassis
(MC-700/MC-1500/MC-1500R/MC-1500R48)
Wall mounting and DIN-rail installation supported
Standard
Complies with IEEE 802.3 10BASE-T
Complies with IEEE 802.3u 100BASE-TX/100BASE-FX
Complies with IEEE 802.3ab 1000BASE-T
Complies with IEEE 802.3z 1000BASE-SX/LX
IEEE 802.3x full-duplex ow control; back pressure for
half duplex to prevent packet loss
3. Hardware Introduction
3.1 Front Panel and LED Indicators
GT-1205A Front Panel
The GT-1205A consists of two 100/1000BASE-X SFP slots and
one auto-sensing 10/100/1000Mbps Ethernet RJ45 port. Figure
1 shows the front panel of the GT-1205A.
1000
1
1
22
3
PWR LNK/
ACT
Figure 1: GT-1205A Front Panel
4. Redundancy Overview
The GT-1205A provides rapid ber redundancy of link for highly
critical Ethernet applications. The redundant mode supports
auto-recover function. If the destination port of a packet is
linked down, it will forward the packet to the other port of the
backup pair. The following gure shows the redundant function.
Figure 4: Redundancy Behavior Topology
Link status auto detection and redundancy of dual ports with
the same connector type.
Only the Primary Port is active at a time, the Backup Port is
blocked.
3.2 Rear Panel
The rear panel of the GT-1205A has one DC jack, which
accepts an input power of 5V DC with 2A. The brand-new DIP
switch designed for 1000BASE-X SFP module or 100BASE-FX
SFP module supports on dual SFP slots. The default DIP switch
mode is 1000BASE-X.
SFP Speed
5V DC
1000BASE-X 100BASE-FX
Figure 2: GT-1205A Rear Panel
Caution
Please power off and power on the GT-1205A after
adjusting the DIP switch setting.
Power Information
The center pin diameter of the GT-1205A’s power jack is
2.5mm and the power jack allows an input power of 5V DC.
It conforms to the bundled AC-DC adapter and PLANETs
media chassis. Should you have any issue about the power
connection, please contact your local sales representative.
Please keep the AC-DC adapter as a spare part when your
GT-1205A is installed to a Media Chassis.
2. Product Features
Interface
Dual 100/1000BASE-X SFP ber-optic slots
One 10/100/1000BASE-T copper port with auto MDI/MDIX
function
Auto-negotiation for 10/100/1000BASE-T; half-duplex or full-
duplex for 10Mbps and 100Mbps, full-duplex for 1000Mbps
Supports maximum frame size up to 10K jumbo packet
size
IEEE 802.1Q tagged VLAN transparent, multicast passthrough
Redundancy
Link status auto-detection and redundancy of dual ports
with the same connector type
Allows only the Primary Port or the Backup Port to acti-
vate at a time
- When Primary Port link failure occurs, the trac swaps
to Backup Port automatically
- Once the Primary Port link regains, the trac swaps
from the Backup Port to the Primary Port
- Redundant hardware ber port
Mechanical
External 5V DC, 2.5A power supply
LED indicators for easy network diagnostics
DIP switch for 100FX or 1000X SFP module supports on
dual SFP slots
DIP switch for 3-port operation in Gigabit switch mode or
redundant mode
GT-1205A LED Indication
System
LED Color Function
PWR Green Lit when +5V DC power is detected.
100/1000BASE-X SFP Slots
LED Color Function
1Green
Lit Indicates that the ber optical port is
linked up.
Blink Indicates that the converter is actively
sending or receiving data over that port.
O Indicates that the ber optical port is
linked down.
2Green
Lit Indicates that the ber optical port is
linked up.
Blink Indicates that the converter is actively
sending or receiving data over that port.
O Indicates that the ber optical port is
linked down.
10/100/1000BASE-T Port
LED Color Function
LNK/
ACT Orange
Lit Indicates that the copper port is linked up.
Blink Indicates that the converter is actively
sending or receiving data over that port.
O Indicates that the copper port is linked
down.
1000 Green
Lit Indicates that the copper port is
operating at 1000Mbps.
O Indicates that the copper port is linked
down 10/100Mbps or .
2.5mm
DC Receptacle 2.5mm
+5V for each slot
DC receptacle is 2.5mm wide that conforms to the GT-
1205A’s 2.5mm DC jack's central post. Do not install any
improper unit.
The device is a power-required device, meaning it will not work
till it is powered. If your networks should be active all the
time, please consider using UPS (uninterrupted power supply)
for your device. It will prevent you from network data loss or
network downtime.
In some areas, installing a surge suppression device may
also help to protect the GT-1205A from being damaged by
unregulated surge or current.
3.3 Side View
The side panel of the GT-1205A has a DIP switch for setting to
the 3-port switch mode or the 2-port redundant mode. When
ON” “OFF, it is in the 2-port redundant mode. And when , it
is in the 3-port switch mode.
OFF ON
Redundant
3-Port Switch OFF
2-Port Redundant ON
Figure 3: GT-1205A Side Panel
When the Primary Port’s link failure occurs, the trac will
swap to Backup Port automatically.
Once the link of the Primary Port is back, the trac will
swap from Backup Port to Primary Port.
5. Installing The Converter
The GT-1205A can be connected over ber optic cabling at a
distance extended from 550 meters to 2km (multi-mode ber)
to 10/20/40/60/80/120 kilometers (single-mode ber or WDM
ber), using the 100/1000BASE-X SFP modules. The SFP
modules are hot-pluggable and hot-swappable. You can plug in
and out the SFP modules to and from any SFP port without
having to power down the GT-1205A.
To install GT1205A, please follow these steps to install the
GT-1205A:
Ethernet Installation
Step 1: Turn o the power of the device/station in a network
to which the GT-1205A will be attached.
Step 2: Ensure that there is no activity in the network.
Step 3: Slide in the 100/1000BASE-X SFP module. Make sure
both sides of the SFP modules are with the same
media type, for example, 100BASE-FX/2km multi-
mode to 100BASE-FX/2km multi-mode, 1000BASE-
SX/550m multi-mode to 1000BASE-SX/550m
multi-mode or 1000BASE-LX/10km single mode to
1000BASE-LX/10km single mode.
- 9 -
- 10 -
- 11 -
- 12 - - 13 -
100/1000BASE-X
LC Fiber 100/1000BASE-X
LC Fiber
100/1000BASE-X
SFP Module
5V DC power
10/100/1000BASE-T
UTP
Figure 5: GT-1205A Gigabit Media Converter Standalone Installation
Step 4: Connect the ber cable. Attach the duplex LC
connector on the network cable to the SFP modules.
Step 5: Attach ber cable from the GT-1205A to the ber
network. TX, RX must be paired at both ends.
Step 6: Connect the 5V DC power adapter to the GT-1205A
and verify that the Power LED lights up.
Step 7: Turn on the power of the device/station; the LINK
LED should light up when all cables are well attached.
Note
1. It is recommended to use PLANET MFB/MGB
series SFP modules for the GT-1205A. If you
insert an SFP module that is not supported, the
GT-1205A will not recognize it. Please check
appendix or go visit our Web site for detailed
specification. http://www.planet.com.tw
2. To prevent from optic acceptor malfunction,
check both the wires and transmitter before
powering on the converter.
6 Cable Connection Parameter
The wiring details are shown below:
Duplex Connection Limitation (max.)
Twisted Pair
Half/Full Node to Node
Node to Switch/Hub 100 meters
Fiber Optic Cables:
Standard
(Wavelength)
100BASE-FX
(1310nm)
1000BASE-SX
(850nm)
1000BASE-LX
(1310nm)
Fiber Type
& Cable
Specications
Multi-mode 50/12m or
62.5/125μm
Single-mode 9/125μm
7.ProductSpecications
Model GT-1205A
Interface Specications
Hardware Version 4
Ports Copper 1 x 10/100/1000BASE-T port
Fiber 2 x 100/1000BASE-X SFP slots
Note
3. To remove the SFP module, please remove the
fiber connectors in advance and push the belt
or latch of the module. Pull out the module
with force may damage the module and the GT-
1205A.
Media Converter Chassis Installation
To install the GT-1205A in a or standard 10-inch 19-inch
rack, follow the instructions described below.
Step 1: Place your GT-1205A on a hard at surface, with the
front panel positioned towards your front side.
Step 2: Carefully slide in the module until it is fully and rmly
tted into the slot of the chassis; the Power LED of
the GT-1205A will turn ON.
Figure 6: Inserting GT-1205A into an available slot
Caution
1. Never push the converter into the slot with
force; it could damage the chassis.
2. The Media Converter Chassis supports hot-swap;
there is no need to turn off the whole chassis
before sliding in the new converter.
Cable
Twisted-
pair
10BASE-T: 2-pair UTP Cat 3, 4, 5, up to
100 meters
100BASE-TX: 2-pair UTP Cat 5, 5e up to
100 meters
1000BASE-T: 4-pair UTP Cat 5e, 6 up to
100 meters
Fiber-
optic
Cable
1000BASE-SX:
50/125μm or 62.5/125μm multi-mode ber
cable, from 220 and 550 meters to 2km.
1000BASE-LX:
9/125μm single-mode cable, with distance
of 10/20/40/80/120km (vary on SFP
module)
100BASE-FX:
50/125μm or 62.5/125μm multi-mode ber
cable, up to 2km (vary on SFP module)
9/125μm single-mode cable, with distance
for 20/40/60m (vary on SFP module)
Hardware Specications
Switch
Architecture Store and Forward
Flow Control Back pressure for half duplex.
IEEE 802.3x pause frame for full duplex
Fabric 6Gbps
Throughput
(packet per
second)
4.4Mpps
Maximum Packet
Size 10K bytes
LED Display
System: One Power LED (Green)
Fiber Port: Two LNK/ACT LEDs (Green)
TP Port : One Speed LED (Green),
One LNK/ACT LED (Orange)
Dimensions
(W x D x H) 94 x 70 x 26mm
Weight 180g (device only)
Power
Requirement 5V DC, 2A max.
Power
Consumption 2.8 watts/9.5BTU per hour (max.)
Environment
Operating
environment 0 ~ 50 degrees C
Storage
environment -10 ~ 70 degrees C
Operating
Humidity
5 ~ 95%, relative humidity
(non-condensing)
Storage Humidity 5 ~ 95%, relative humidity
(non-condensing)
Standard Conformance
EMI Safety FCC Class B, CE
Standard
Compliance
IEEE 802.3
IEEE 802.3u
IEEE 802.3ab
IEEE 802.3z
IEEE 802.3x
10BASE-T
100BASE-TX/100BASE-FX
1000BASE-T
1000BASE-SX/LX
Flow Control
PLANET TECHNOLOGY CORPORATION
e-mail: sales@planet.com.tw http://www.planet.com.tw
10F., No.96, Minquan Rd., Xindian Dist., New Taipei City, Taiwan, R.O.C. Tel:886-2-2219 2219 9528-9518 Fax:886-2- -
EC Declaration of Conformity
For the following equipment:
*Type of Product : 10/100/1000B -T to Dual 1000B -ASE ASE X SFP Media Converter
*Model Number : GT-1205A
* Produced by:
Manufacturer‘s Name : Planet Technology Corp.
Manufacturer‘s Address : 10F., No.96, Minquan Rd., Xindian Dist.,
New Taipei City 231, Taiwan R.O.C.
is herewith confirmed to comply with the requirements set out in the Council Directive on the
Approximation of the Laws of the Member States relating to Electromagnetic Compatibility
Directive on 2014/30/EU.
For the evaluation regarding the EMC, the following standards were applied:
EN 55032 (2015)
EN 61000-3-2 (2014)
EN 61000-3-3 (2013)
EN 55024 ( : 2015) 2010 + A1
R esponsible for marking this declaration if the:
Manufacturer Authorized representative established within the EU
Authorized representative established within the EU (if applicable):
Company Name: Planet Technology Corp.
Company Address: 10F., No.96, Minquan Rd., Xindian Dist., New Taipei City 231, Taiwan R.O.C.
Person responsible for making this declaration
Name, Surname Kent Kang
Position / Title : Director
Taiwan
23, 2019 Aug.
Place
Date
Legal Signature


Specyfikacje produktu

Marka: Planet
Kategoria: Niesklasyfikowane
Model: GT-1205A

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z Planet GT-1205A, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje Niesklasyfikowane Planet

Planet

Planet LS100-SMK Instrukcja

9 Października 2024
Planet

Planet IGS-1000-4UP2X Instrukcja

9 Października 2024
Planet

Planet NMS-AIoT Instrukcja

9 Października 2024
Planet

Planet NMS-ST Instrukcja

9 Października 2024
Planet

Planet IGS-R4215-24T4X Instrukcja

5 Października 2024
Planet

Planet IXT-900-2X1UP Instrukcja

4 Października 2024
Planet

Planet AVS-4210-24HP4X Instrukcja

4 Października 2024
Planet

Planet TSN-5225-4T Instrukcja

4 Października 2024
Planet

Planet MGB-LX Instrukcja

4 Października 2024
Planet

Planet ISW-514PTF Instrukcja

3 Października 2024

Instrukcje Niesklasyfikowane

Najnowsze instrukcje dla Niesklasyfikowane

Stihl

Stihl HT 70 Instrukcja

15 Października 2024
Ernesto

Ernesto H14270 Instrukcja

15 Października 2024
Uniden

Uniden BT MIC KIT Instrukcja

15 Października 2024
Vaude

Vaude Omnis Bike 26 Instrukcja

15 Października 2024
ART

ART ProChannel II Instrukcja

15 Października 2024
Aukey

Aukey DR02J Instrukcja

15 Października 2024
Master Lock

Master Lock 653EURD Instrukcja

15 Października 2024
Roland

Roland FR-18 Diatonic Instrukcja

15 Października 2024