070220-28 ALT4-LE 100003978
OPERATING AND
INSTALLATION
INSTRUCTIONS
SAFETY NOTICE
If this stove is not properly installed, a
house re may result. For your safety,
follow the installation instructions.
Contact local building or re ofcials
about restrictions and installation
inspection requirements in your area.
TESTED and LISTED to;
CAN/ULC S627 AND UL 1482
IMPORTANT:
THESE INSTRUCTIONS ARE TO
REMAIN WITH THE HOMEOWNER
MODEL:
ALDERLEA T4 LE
SERIAL #
Visit www.pacificenergy.net for the most recent version of this manual
Meets the U.S. Environmental Protection
Agency's 2020 Particulate Emission Standards
(Crib Wood).
Experience will give you the right settings for proper combustion and efcient burning. Remember the correct air inlet
setting is affected by variables such as type of wood, outside temperature, chimney size and weather conditions. With
practice, you will become procient in operating your heater and will obtain the performance for which it was designed.
Table of Contents
HOT GLASS WILL CAUSE
BURNS.
DO NOT UCH GLASS UNTIL TO
COOLED.
NEVER ALLOW CHILDREN TO
TOUCH GLASS.
!
WARNING
PLEASE SAVE THESE INSTRUCTIONS
NOTE: WE STRONGLY RECOMMEND THAT SMOKE AND CARBON MONOXIDE DETECTORS BE INSTALLED IN
THE AREA WHERE THE HEATER IS TO BE INSTALLED.
If smoke detectors have been previously installed, you may notice that they are operating more frequently. This may be
due to curing of stove paint or fumes caused by accidentally leaving the re door open. Do not disconnect the detectors.
SAFETY NOTICE: If this stove is not properly installed, a house fire may result. For your safety, follow the
installation instructions. Contact local building or fire officials about restrictions and installation inspection
requirements in you area.
Please read this entire manual before you install and use your new room heater. Failure to follow instructions may result
in property damage, bodily injury, or even death.
Table of Contents 2 ......................................................................
Rating Label 3 ..............................................................................
Efciency and BTU Output 3 .................................................
Safety 4 ........................................................................................
Chimney Smoke and Creosote Formation 4 .........................
Chimney Fires 4 ....................................................................
To Avoid a Chimney Fire..................................................... 5
In the event of a Chimney Fire 5 ...........................................
Curing of the Paint Finish 5 ...................................................
Operation 6 ...................................................................................
Wood Selection 6 ..................................................................
DO NOT BURN : 6 .................................................................
How to Test Your Wood 6 ......................................................
Lighting a re 7 ......................................................................
Normal Operation 7 ...............................................................
Restarting After Extended or Overnight Burns 8 ..................
Proper Draft 8 ........................................................................
Ash Removal 8 ......................................................................
Ash Clean out system: 8 .....................................................
Disposal of Ashes............................................................... 8
Maintenance 9 ..............................................................................
Maintenance Checks 10 ...............................................................
Weekly: 10 .............................................................................
Monthly 10 ............................................................................
When Cleaning the Chimney System: 10 ..............................
Blower: 10 .............................................................................
Bafe: 10 ...............................................................................
Bafe / Tube Removal 11 .............................................................
Tube / Baffle Board Removal 11 .........................................
Installation 11 ........................................................................
Assembly 12 .................................................................................
Dimensions 12 ..............................................................................
Floor Protector 13 ........................................................................
Residential Installation ............................................................. 14
Clearances: 14 ......................................................................
Chimney and Connector 15 ..................................................
When using a Double-Wall Connector 15 .............................
When using a Single-Wall (smoke pipe) Connector 15 .........
Combustion Air 16 ........................................................................
Installation Procedure 16 ......................................................
Through Wall Installations (as per NFPA 211) 19 .................
Mobile Home Installation 21 .........................................................
Trouble Shooting 22 .....................................................................
Optional Blower 23 .......................................................................
Blower Operation 23 .............................................................
Firebrick Installation 23 ................................................................
Replacement Parts - Alderlea T4 LE 26 .......................................
WARNING: this product can expose
you to chemicals including ceramic bers,
which are known to the state of California
to cause cancer,and to carbon monoxide,
which is known to the state of California to cause birth
defects or other reproductive harm.
For more information go to www.p65warnings.ca.gov.
This warning is applicable to all
PACIFIC ENERGY FIREPLACE PRODUCTS
ALT 4-LE 070220-28
2100003978
Rating Label
PLEASE SAVE THESE INSTRUCTIONS
This manual describes the installation and operation of the;
Pacic Energy, ALDERLEA T4 LE and ALDERLEA T4 LE Classic freestanding wood heater.
SAFETY NOTICE: If this stove is not properly installed, a house re may result. For your safety, follow the installation
instructions. Contact local building or re ofcials about restrictions and installation inspection requirements in you area.
Please read this entire manual before you install and use your new room heater. Failure to follow instructions may result
in property damage, bodily injury, or even death.
1 Weighted Average Lower Heating Value (LHV) efciency as
tested using CSA B415 Performance testing of solid-fuel-
burning heating appliances. LHV assumes the moisture is
already in a vapour state so there is no loss of energy
2 Weighted Average Higher Heating Value (HHV) efciency
as tested using CSA B415 Performance testing of solid-fuel-
burning heating appliances. HHV includes the energy required
to vaporize the water in the fuel
3 The range of BTU outputs is based on efciency using CSA
B415 Performance testing of solid-fuel-burning heating appli-
ances and burn rates from the low and high EPA tests using
Douglas Fir dimensional lumber.
This heater meets the U.S. Environmental Protection
Agency's 2020 crib wood emission limits for wood
heaters sold after May 15, 2020 using Method 28R.
Under specic test conditions this heater has been
shown to deliver heat at rates ranging from 13,500 to
23,200Btu/hr.
Emissions testing was performed by PFS-TECO Inc.
EPA Certied Emissions 1.9 grams per hour
LHV Tested Efciency 1 78%
HHV Tested Efciency 2 72%
EPA BTU Output 3 13,494 to 23,186 btu/hr.
Maximum Wood Length 18 inches
Ideal Wood Length 16 inches
Fuel Seasoned Cord wood
Efficiency and BTU Output
A.
10 in. / 356 mm
B. 10
in. / 229 mm
C. 7
in. / 152 mm
VISTA LE
D.
19-1/2 in. / 610 mm
E.
14-3/8 in. / 368 mm
F.
16-1/2 in. / 429 mm
ALDERLEA T4 LE
D.
25.6 in. / 650 mm
E.
*14.6 in. / 371 mm
F.
*17.1 in. / 435 mm
CERTIFIED FOR CANADA AND U.S.A. - MODEL / MODÈLE: VISTA VISTA CLASSIC ALDERLEA T4 LE LE LE
LISTED ROOM HEATER, SOLID FUEL TYPE. ALSO FOR USE IN MOBILE HOMES
CERTIFIED TO / CERTIFIÉ POUR: CAN/ULC S627-00 (R2016) / UL 1482-2011
Refer to Intertek’s Directory of Building Products for detailed information
• FOR USE WITH SOLID FUEL (CORDWOOD ) ONLY. DO NOT USE OTHER FUEL TYPES. INSTALL AND USE
IN ACCORDANCE WITH THE MANUFACTURER’S INSTALLATION AND OPERATING INSTRUCTIONS.
• CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT RESTRICTIONS, INSTALLATION PERMIT AND
INSPECTION IN YOUR AREA.
• DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE.
• USE 6 INCH / 150MM DIAMETER MINIMUM 24 MSG BLACK OR LISTED CONNECTOR.
• UNIT CAN BE CONNECTED TO A LINED MASONRY CHIMNEY SUITABLE FOR USE WITH SOLID FUELS.
• DO NOT OBSTRUCT THE SPACE BENEATH THE HEATER.
• DO NOT ROUTE POWER CORD BENEATH HEATER.
• SEE LOCAL BUILDING CODE AND MANUFACTURER'S INSTRUCTIONS FOR PRECAUTIONS REQUIRED
WHEN PASSING A CHIMNEY THROUGH A COMBUSTIBLE WALL OR CEILING.
• DO NOT PASS A CHIMNEY CONNECTOR THROUGH A COMBUSTIBLE WALL OR CEILING.
• MINIMUM CLEARANCE BETWEEN SINGLE WALL CHIMNEY CONNECTOR AND COMBUSTIBLE
MATERIALS-18INCHES/455MM. CLEARANCE MAY BE REDUCED BY THE USE OF LISTED PIPE SHIELDS,
WALL PROTECTORS OR OTHER MEANS APPROVED BY LOCAL BUILDING OR FIRE OFFICIALS.
• COMPONENTS REQUIRED FOR MOBILE HOME INSTALLATION: OUTSIDE AIR KIT.
• HORIZONTAL CONNECTOR NOT PERMITTED IN MOBILE HOMES
• BOTH CHIMNEY SYSTEM AND CONNECTOR MUST BE LISTED TO:
IN CANADA
IN CANADA
IN CANADA
IN CANADA - ULC S-641 LISTED CONNECTOR AND ULC-S-629 LISTED CHIMNEY
- ULC S-641 LISTED CONNECTOR AND ULC-S-629 LISTED CHIMNEY
- ULC S-641 LISTED CONNECTOR AND ULC-S-629 LISTED CHIMNEY
- ULC S-641 LISTED CONNECTOR AND ULC-S-629 LISTED CHIMNEY
IN CANADA - ULC S-641 LISTED CONNECTOR AND ULC-S-629 LISTED CHIMNEY
IN USA
IN USA
IN USA
IN USA - UL-103 HT LISTED CONNECTOR AND CHIMNEY
- UL-103 HT LISTED CONNECTOR AND CHIMNEY
- UL-103 HT LISTED CONNECTOR AND CHIMNEY
- UL-103 HT LISTED CONNECTOR AND CHIMNEY
IN USA - UL-103 HT LISTED CONNECTOR AND CHIMNEY
• USE COMPONENTS SPECIFIED IN PACIFIC ENERGY INSTALLATION INSTRUCTIONS.
• APPLIANCE MUST BE INSTALLED WITH PEDESTAL OR LEG KIT ATTACHED.
• OPTIONAL COMPONENTS - FAN KIT (part # 11140001), FAN ELECTRICAL RATING: 115V, 60HZ, 1.0 AMP
• DO NOT USE GRATE OR ELEVATE FIRE - BUILD WOOD FIRE DIRECTLY ON HEARTH.
• DO NOT OVERFIRE - IF CHIMNEY OR CONNECTOR GLOWS, YOU ARE OVERFIRING.
• CAUTION: RISK OF EXCESSIVE TEMPERATURES - OPERATE ONLY WITH FEED DOOR CLOSED. OPEN
TO FEED FIRE ONLY. - KEEP ASH DUMP CLOSED DURING FIRING OF THE HEATER.
• KEEP FURNISHINGS AND OTHER COMBUSTIBLE MATERIALS WELL AWAY FROM HEATER.
• REPLACE GLASS ONLY WITH CERAMIC GLASS.
• COMBUSTIBLE FLOOR MUST BE PROTECTED BY A CONTINUOUS NON-COMBUSTIBLE MATERIAL
EXTENDED TO THE FRONT, SIDES AND BACK AS INDICATED.
• INSPECT AND CLEAN CHIMNEY FREQUENTLY - UNDER CERTAIN CONDITIONS OF USE, CREOSOTE
BUILDUP MAY OCCUR RAPIDLY.
• THIS WOOD HEATER NEEDS PERIODIC INSPECTION AND REPAIR FOR PROPER OPERATION. - CONSULT
THE OWNER’S MANUAL FOR FURTHER INFORMATION.
• IT IS AGAINST FEDERAL REGULATIONS TO OPERATE THIS WOOD HEATER IN A MANNER INCONSISTANT
WITH THE OPERATING INSTRUCTIONS IN THE OWNER’S MANUAL
* AS TESTED - PIPE SHIELD MAY BE REQUIRED BY LOCAL AUTHORITIES.
** COMBUSTIBLE ALCOVE SIZE: DEPTH - 3 FT. / .91 M MAX., HEIGHT 6 ft. / 1.83 m MIN.,
MINIMUM CLEARANCES TO
COMBUSTIBLE MATERIALS/
DÉGAGEMENTS MINIMALES AUX
MATÉRIAUX COMBUSTIBLES
DO NOT REMOVE THIS LABEL
RESIDENTIAL and MOBILE HOME
INSTALLATION USING DOUBLE WALL
CONNECTOR /
INSTALLATION RÉSIDENTIELLE AVEC
DÉGAGEMENT MINIMAL, UTILISANT UN
RACCORD DE MUR DOUBLE
RESIDENTIAL INSTALLATION
USING SINGLE WALL CONNECTOR*/
INSTALLATION RÉSIDENTIELLE UTILISANT
UN RACCORD DE MUR SIMPLE
IN CANADA G. 18 INCHES / 450 MM
AU CANADA
H. 8 INCHES / 200 MM
I. 8 INCHES / 200 MM
IN U.S.A. G. 16 INCHES / 405 MM
H. 5 INCHES / 127 MM
I. 0 INCHES / 0 MM
C#4001507
• À UTILISER UNIQUEMENT AVEC DU COMBUSTIBLE SOLIDE. NE PAS UTILISER D’AUTRES TYPES DE CARBURANT.
• INSTALLEZ ET UTILISEZ SELON LES INSTRUCTIONS D’INSTALLATION ET D’OPÉRATION FOURNI AVEC L’APPAREIL..
• CONTACTEZ LES OFFICIELS DE LA CONSTRUCTION OU DE SERVICE D’INCENDIE POUR DES INFORMATIONS QUANT AUX
RESTRICTIONS. PERMIS D’INSTALLATION ET INSPECTIONS DANS VOTRE RÉGION.
• NE RELIEZ PAS CET APPAREIL À UN CONDUIT DE CHEMINÉE DESSERVANT DÉJÀ UN AUTRE APPAREIL .
• UTILISEZ UN RACCORDEMENT NOIR OU CLASSÉ DE 24 MSG ET AVEC UN DIAMÈTRE D’AU MOINS 6 POUCES / 150 mm.
• PEUT ÊTRE CONNECTÉ À UNE CHEMINÉE DE MAÇONNERIE ALIGNÉE PRÊTE À L’EMPLOI AVEC DES COMBUSTIBLES SOLIDES.
• N’OBSTRUEZ PAS L’ESPACE SOUS LE CAISSON DU POÊLE
• CONSULTEZ LE CODE LOCAL DE CONSTRUCTION ET LES INSTRUCTIONS DU FABRICANT QUANT AUX PRÉCAUTIONS À
PRENDRE LORSQUE VOUS FAITES PASSER UNE CHEMINÉE À TRAVERS D’UN MUR OU D’UN PLAFOND COMPOSÉS DE
MATÉRIAUX COMBUSTIBLES.
• NE FAITES PAS PASSER UN RACCORDEMENT DE CHEMINÉE À TRAVERS D’UN MUR OU D’UN PLAFOND COMPOSÉS DE
MATÉRIAUX
• DÉGAGEMENT MINIMAL ENTRE UN RACCORDEMENT DE CHEMINÉE À UN MUR SIMPLE ET TOUT MATÉRIEL COMBUSTIBLE
- 18 POUCES / 455 mm. CE DÉGAGEMENT PEUT ÊTRE RÉDUIT EN UTILISANT DES PROTECTEURS DE TUYAUX CLASSÉS,
PROTECTEURS DE MUR OU AUTRES MOYENS APPROUVÉS PAR LES OFFICIELS DE LA CONSTRUCTION OU DU SERVICE
D’INCENDIE DE VOTRE RÉGION.
CONNECTEUR HORIZONTAL NON PERMIS DANS MAISONS MOBILES
• L’APPARIEL DOIT COMPORTER UN ENSEMBLE POUR PIEDSTABLE OU SUR PATTES.
• PIÈCES REQUISES POUR INSTALLATION EN MAISON MOBILE OU EN ALCÔVE: NÉCESSAIRE
D’APPROVISIONNEMENT D’AIR EXTÉRIEUR ET L’UN DES RACCORDS SUIVANTS: EN COMBINAISON
AVEC L’UN DES SYSTÈMES DE CHEMINÉE COMPATIBLES SUIVANTS:
AU CANADA - LE ULC S-641 CONNECTEUR ENUMERES ET ULC-S-629 ONT ENUMERE CHEMINEE
• PIÈCES EN OPTION - NÉCESSAIRES DE SOUFFLERIE, INDICES ÉLECTRIQUES DE SOUFFLERIE: 115V, 60HZ, 1.0 AMP. LE FIL
ÉLECTRIQUE NE DOIT PAS ÊTRE PLACÉ SOUS LE POÈTE. LE FIL ÉLECTRIQUE NE DOIT PAS ÊTRE PLACÉ SOUS LE POÊLE
• ATTENTION: RISQUE DE TEMPÉRATURES EXCESSIVES - GARDES LE TIROIR DE CENDRES FERMÉ PENDANT L’ALLUMAGE DU
POÈTE.
• OPÉREZ SEULEMENT LORSQUE LA PORTE D’ALIMENTATION EST FERMÉE. • OUVREZ SEULEMENT POUR ALIMENTER LE FEU.
• GARDEZ LES MEUBLES ET AUTRES MATÉRIAUX COMBUSTIBLES BIEN ÉLOIGNÉS DU POÊLE.
• REMPLACES LA VITRE AVEC UNIQUEMENT DE LA VITRE CÉRAMIQUE.
*
TEL QUO ÉPROUVÉ UN PROTECTEUR DE TUYAU PEUT ÊTRE REQUIS PAR LES AUTORITÉS LOCALES
**
DIMENSION D’ALCOVE COMBUSTIBLE: PROFONDEUR - 3 PIEDS / .91M, HAUTEUR 7 PIEDS/2.1M, LARGEUR 4 PIEDS/1.2M
MINIMUM.
LE PLANCHER COMBUSTIBLE DOIT ÊTRE PROTÉGÉ PAR UN MATÉRIEL NON-COMBUSTIBLE TOUT D’UNE PIÈCE QUI DOIT
S’ÉTENDRE DE PAR LE DEVANT, LES COTÉS ET L’ARRIÈRE TEL QU’INDIQUÉ.
• CET APPRAREIL DE CHAUFFAGE AU BOIS DOIT FAIRE L’OBJETD’ENTRETIENS ET D’INSPECTIONS P
É
RIODIQUES
POUR UN FONCTIONNEMENT AD
É
QUAT. CONSULTEZ LE MANUEL D’UTILISATION POUR PLUS D’INFORMATION.
A. SIDEWALL TO UNIT/
MUR DE CÔTE / APPAREIL
B. BACKWALL TO UNIT/
M
UR DE FOND / APPAREIL
C. CORNER TO UNIT/
COIN / APPAREIL
D. SIDEWALL TO CONNECTOR/
MUR DE CÔTE / RACCORD
E. BACKWALL TO CONNECTOR/
MUR DE FOND / RACCORD
F. CORNER TO CONNECTOR/
COIN / RACCORD
BACK I
HEATER
G
SIDE
H
FRONT
SIDE
H
COTE
COTE
DEVANT
POELE
DOS
MADE IN CANADA/
FABRIQUÉ AU CANADA
100002909060619
MANUFACTURED BY/
FABRIQUÉ PAR:
PACIFIC ENERGY FIREPLACE PRODUCTS LTD.
2975 ALLENBY RD., DUNCAN, BC V9L 6V8
ADJACENT WALL
BACK WALL
D
A
SIDE WALL
BE
ADJACENT WALL
F
C
MUR COTE
MUR ARRIERE
MUR ADJACENT
MUR ADJACENT
1.9 g/hr
U.S. ENVIRONMENTAL PROTECTION AGENCY.
Certifi ed to comply with 2020 CRIB WOOD PARTICULATE EMISSION
STANDARDS, using Method 28R//
Certifi é conforme aux normes sur les
émissions de particules de 2020.
A.
8 in. / 330 mm
B.
8 in. / 191 mm
C.
5 in. / 127 mm
VISTA LE
D.
17-1/2in. / 584 mm
E.
12-3/8 in. / 330 mm
F.
14-1/2in. / 403 mm
ALDERLEA T4 LE
D.
24.6 in. / 612 mm
E.
13.1 in. / 333 mm
F.
16.1 in. / 410 mm
DATE OF MANUFACTURE
SAMPLE
ALT 4-LE 070220-28 3100003978
Specyfikacje produktu
Marka: | Pacific Energy |
Kategoria: | Podgrzewacz |
Model: | Alderlea T4 LE |
Potrzebujesz pomocy?
Jeśli potrzebujesz pomocy z Pacific Energy Alderlea T4 LE, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą
Instrukcje Podgrzewacz Pacific Energy
22 Września 2024
22 Września 2024
22 Września 2024
22 Września 2024
22 Września 2024
21 Września 2024
21 Września 2024
21 Września 2024
21 Września 2024
21 Września 2024
Instrukcje Podgrzewacz
- Podgrzewacz Bauknecht
- Podgrzewacz Tesy
- Podgrzewacz Electrolux
- Podgrzewacz DeLonghi
- Podgrzewacz AEG
- Podgrzewacz Beko
- Podgrzewacz Beurer
- Podgrzewacz Xiaomi
- Podgrzewacz Gorenje
- Podgrzewacz SHX
- Podgrzewacz Russell Hobbs
- Podgrzewacz Tefal
- Podgrzewacz Milwaukee
- Podgrzewacz Philips
- Podgrzewacz Livoo
- Podgrzewacz SilverCrest
- Podgrzewacz Dometic
- Podgrzewacz Bosch
- Podgrzewacz Parkside
- Podgrzewacz Candy
- Podgrzewacz Ferroli
- Podgrzewacz Global
- Podgrzewacz Brentwood
- Podgrzewacz Nobo
- Podgrzewacz Midea
- Podgrzewacz Infiniton
- Podgrzewacz Conceptronic
- Podgrzewacz Nedis
- Podgrzewacz Stanley
- Podgrzewacz Black & Decker
- Podgrzewacz Adler
- Podgrzewacz Rinnai
- Podgrzewacz Fenix
- Podgrzewacz Hendi
- Podgrzewacz Quigg
- Podgrzewacz Domo
- Podgrzewacz Ardes
- Podgrzewacz Taurus
- Podgrzewacz Orbegozo
- Podgrzewacz Blaupunkt
- Podgrzewacz Vivax
- Podgrzewacz Stadler Form
- Podgrzewacz Ambiano
- Podgrzewacz DeWalt
- Podgrzewacz Danby
- Podgrzewacz Einhell
- Podgrzewacz Eberle
- Podgrzewacz Jocel
- Podgrzewacz Hyundai
- Podgrzewacz Bimar
- Podgrzewacz Rowenta
- Podgrzewacz Mesko
- Podgrzewacz Master
- Podgrzewacz Honeywell
- Podgrzewacz Chauvet
- Podgrzewacz ECG
- Podgrzewacz Unold
- Podgrzewacz Truma
- Podgrzewacz Fiap
- Podgrzewacz Dyson
- Podgrzewacz Broan
- Podgrzewacz Trisa
- Podgrzewacz RYOBI
- Podgrzewacz Zelmer
- Podgrzewacz Cuisinart
- Podgrzewacz Wilfa
- Podgrzewacz Eureka
- Podgrzewacz Bomann
- Podgrzewacz Clean Air Optima
- Podgrzewacz Teesa
- Podgrzewacz DEDRA
- Podgrzewacz Emerio
- Podgrzewacz Create
- Podgrzewacz H.Koenig
- Podgrzewacz Melissa
- Podgrzewacz Enders
- Podgrzewacz Beper
- Podgrzewacz Eurolite
- Podgrzewacz MPM
- Podgrzewacz OneConcept
- Podgrzewacz Emos
- Podgrzewacz Philco
- Podgrzewacz Corbero
- Podgrzewacz Zanussi
- Podgrzewacz Ravanson
- Podgrzewacz BaseTech
- Podgrzewacz Thermex
- Podgrzewacz Perel
- Podgrzewacz Fagor
- Podgrzewacz GoldAir
- Podgrzewacz Koenic
- Podgrzewacz Trotec
- Podgrzewacz Everdure
- Podgrzewacz Thomson
- Podgrzewacz Trumatic
- Podgrzewacz Izzy
- Podgrzewacz Velleman
- Podgrzewacz Klarstein
- Podgrzewacz Güde
- Podgrzewacz ATIKA
- Podgrzewacz Cecotec
- Podgrzewacz AFK
- Podgrzewacz JANDY
- Podgrzewacz Eta
- Podgrzewacz Camry
- Podgrzewacz Steba
- Podgrzewacz NewAir
- Podgrzewacz Lenoxx
- Podgrzewacz Qlima
- Podgrzewacz Scarlett
- Podgrzewacz GUTFELS
- Podgrzewacz Nevir
- Podgrzewacz TriStar
- Podgrzewacz Bartscher
- Podgrzewacz Dimplex
- Podgrzewacz Harvia
- Podgrzewacz Baxi
- Podgrzewacz Invicta
- Podgrzewacz Lavorwash
- Podgrzewacz Fluval
- Podgrzewacz DURO PRO
- Podgrzewacz Maginon
- Podgrzewacz SPC
- Podgrzewacz DCG
- Podgrzewacz Brandson
- Podgrzewacz Vornado
- Podgrzewacz G3 Ferrari
- Podgrzewacz Omega Altise
- Podgrzewacz Westfalia
- Podgrzewacz Hayward
- Podgrzewacz Remko
- Podgrzewacz Clatronic
- Podgrzewacz NEO Tools
- Podgrzewacz SVAN
- Podgrzewacz Ariete
- Podgrzewacz Napoleon
- Podgrzewacz Princess
- Podgrzewacz Carson
- Podgrzewacz Innoliving
- Podgrzewacz Argoclima
- Podgrzewacz Sunbeam
- Podgrzewacz Solac
- Podgrzewacz Elro
- Podgrzewacz Olympia
- Podgrzewacz Heller
- Podgrzewacz Mora
- Podgrzewacz Duronic
- Podgrzewacz Kenmore
- Podgrzewacz VOX
- Podgrzewacz Ferm
- Podgrzewacz Pelgrim
- Podgrzewacz Solis
- Podgrzewacz Orion
- Podgrzewacz DCS
- Podgrzewacz Blumfeldt
- Podgrzewacz SereneLife
- Podgrzewacz Vemer
- Podgrzewacz Rommelsbacher
- Podgrzewacz Sencor
- Podgrzewacz Vonroc
- Podgrzewacz Powerfix
- Podgrzewacz EasyMaxx
- Podgrzewacz Kalorik
- Podgrzewacz Suntec
- Podgrzewacz Signature
- Podgrzewacz Livington
- Podgrzewacz Lervia
- Podgrzewacz WAGAN
- Podgrzewacz Kunft
- Podgrzewacz Grunkel
- Podgrzewacz Zibro
- Podgrzewacz Becken
- Podgrzewacz Haeger
- Podgrzewacz Masport
- Podgrzewacz Guzzanti
- Podgrzewacz Sygonix
- Podgrzewacz AstralPool
- Podgrzewacz Cotech
- Podgrzewacz Gre
- Podgrzewacz Tectro
- Podgrzewacz Eurom
- Podgrzewacz Maestro
- Podgrzewacz Mill
- Podgrzewacz PRIME3
- Podgrzewacz Sogo
- Podgrzewacz Sonnenkönig
- Podgrzewacz Lifesmart
- Podgrzewacz Lasko
- Podgrzewacz Flama
- Podgrzewacz Bestron
- Podgrzewacz Optimum
- Podgrzewacz Profile
- Podgrzewacz Swan
- Podgrzewacz Alpina
- Podgrzewacz AKO
- Podgrzewacz Argo
- Podgrzewacz Haverland
- Podgrzewacz Korona
- Podgrzewacz Sinbo
- Podgrzewacz Jata
- Podgrzewacz Sun Joe
- Podgrzewacz EWT
- Podgrzewacz Mellerware
- Podgrzewacz Nestor Martin
- Podgrzewacz Heinner
- Podgrzewacz Termozeta
- Podgrzewacz Eldom
- Podgrzewacz Cresta
- Podgrzewacz Defy
- Podgrzewacz Stiebel Eltron
- Podgrzewacz Bionaire
- Podgrzewacz Otsein-Hoover
- Podgrzewacz Real Flame
- Podgrzewacz Evolar
- Podgrzewacz Zibro Kamin
- Podgrzewacz Air King
- Podgrzewacz Royal Sovereign
- Podgrzewacz King
- Podgrzewacz Maxwell
- Podgrzewacz Malmbergs
- Podgrzewacz Piazzetta
- Podgrzewacz Heylo
- Podgrzewacz Kent
- Podgrzewacz Arnold Rak
- Podgrzewacz Ufesa
- Podgrzewacz CasaFan
- Podgrzewacz Olimpia Splendid
- Podgrzewacz Wamsler
- Podgrzewacz Duux
- Podgrzewacz Imetec
- Podgrzewacz Topcraft
- Podgrzewacz Blaze
- Podgrzewacz Zodiac
- Podgrzewacz Primo
- Podgrzewacz Dovre
- Podgrzewacz Creda
- Podgrzewacz SuperFish
- Podgrzewacz Konig
- Podgrzewacz Plieger
- Podgrzewacz Zehnder
- Podgrzewacz Essentiel B
- Podgrzewacz Team
- Podgrzewacz Fantini Cosmi
- Podgrzewacz CaterChef
- Podgrzewacz Zephir
- Podgrzewacz Dantherm
- Podgrzewacz Brixton
- Podgrzewacz Superior
- Podgrzewacz La Nordica
- Podgrzewacz Jotul
- Podgrzewacz HQ
- Podgrzewacz Vasco
- Podgrzewacz Noveen
- Podgrzewacz Nectre
- Podgrzewacz Cadel
- Podgrzewacz PAX
- Podgrzewacz Jaga
- Podgrzewacz Extraflame
- Podgrzewacz Lynx
- Podgrzewacz Just Fire
- Podgrzewacz Hartig And Helling
- Podgrzewacz TAIDEN
- Podgrzewacz Veito
- Podgrzewacz Etherma
- Podgrzewacz Orava
- Podgrzewacz Nordic Fire
- Podgrzewacz United
- Podgrzewacz Haas+Sohn
- Podgrzewacz Eurotronic
- Podgrzewacz Ausclimate
- Podgrzewacz Wanders
- Podgrzewacz Tecno Air System
- Podgrzewacz Grandhall
- Podgrzewacz Emga
- Podgrzewacz Adax
- Podgrzewacz Heatstrip
- Podgrzewacz Vasner
- Podgrzewacz Escea
- Podgrzewacz Kogan
- Podgrzewacz Braemar
- Podgrzewacz Bromic Heating
- Podgrzewacz Martec
- Podgrzewacz Jindara
- Podgrzewacz Neo
- Podgrzewacz SPT
- Podgrzewacz Hatco
- Podgrzewacz SunRed
- Podgrzewacz Starlyf
- Podgrzewacz Aerian
- Podgrzewacz Hortus
- Podgrzewacz IXL
- Podgrzewacz XPower
- Podgrzewacz True North
- Podgrzewacz WestBend
- Podgrzewacz Prem-i-air
- Podgrzewacz Quadra-Fire
- Podgrzewacz Mr. Heater
- Podgrzewacz Stenda
- Podgrzewacz VIESTA
- Podgrzewacz Apricus
- Podgrzewacz Heatsome
- Podgrzewacz Brivis
- Podgrzewacz Hubbell
- Podgrzewacz HeatStar
- Podgrzewacz Dri Eaz
- Podgrzewacz Regency
- Podgrzewacz Burley
- Podgrzewacz Invroheat
- Podgrzewacz Kaden
- Podgrzewacz Jarden
- Podgrzewacz Noirot
- Podgrzewacz Ouellet
- Podgrzewacz Gossmann
- Podgrzewacz Wulfe
- Podgrzewacz Herschel
- Podgrzewacz Casaya
- Podgrzewacz HyCell
- Podgrzewacz TURBRO
- Podgrzewacz Radialight
- Podgrzewacz Bromic
- Podgrzewacz Sunheat
- Podgrzewacz Heidenfeld
- Podgrzewacz Hcalory
- Podgrzewacz Rowi
- Podgrzewacz Neopower
- Podgrzewacz Arlec
- Podgrzewacz Guardian
- Podgrzewacz Big Ass Fans
- Podgrzewacz Pureheat
- Podgrzewacz EvoHeat
- Podgrzewacz MSW
- Podgrzewacz Solamagic
- Podgrzewacz Contura
- Podgrzewacz Alkari
- Podgrzewacz Longvie
- Podgrzewacz Blue Rhino
- Podgrzewacz Rheem
- Podgrzewacz Gasmate
- Podgrzewacz Scandia
- Podgrzewacz Fire Sense
- Podgrzewacz InfraNomic
- Podgrzewacz Heat Storm
- Podgrzewacz Excelair
- Podgrzewacz Heatscope
- Podgrzewacz Heat1
- Podgrzewacz Kemlan
- Podgrzewacz Perfect Aire
- Podgrzewacz AustWood
- Podgrzewacz Uniprodo
- Podgrzewacz Infratech
- Podgrzewacz Yamazen
- Podgrzewacz TANSUN
- Podgrzewacz Universal Blue
Najnowsze instrukcje dla Podgrzewacz
21 Grudnia 2024
21 Grudnia 2024
20 Grudnia 2024
20 Grudnia 2024
20 Grudnia 2024
19 Grudnia 2024
19 Grudnia 2024
19 Grudnia 2024
19 Grudnia 2024
19 Grudnia 2024