STANDARD EQUIPMENT
MANUAL
AUTO
MANUAL
AUTO
PXHPCS-018
INSTRUCTION MANUAL
SPECIFICATIONS
Input: 18V
No Load Speed: 16,500/min
Max. Pressure: 160psi (11bar)
Max. Flow Rate: 12L/min
Hose Length: 0.6m
Weight: 0.8kg
ozito.com.au
1021
Cordless High Pressure Air
Inator
3 x Ination Adaptors
HIGH PRESSURE
AIR INFLATOR
IN ORDER TO MAKE A CLAIM UNDER THIS WARRANTY YOU
MUST RETURN THE PRODUCT TO YOUR NEAREST BUNNINGS
WAREHOUSE WITH YOUR BUNNINGS REGISTER RECEIPT. PRIOR TO
RETURNING YOUR PRODUCT FOR WARRANTY PLEASE TELEPHONE
OUR CUSTOMER SERVICE HELPLINE:
Australia 1800 069 486
New Zealand 0508 069 486
WARRANTY
TO ENSURE A SPEEDY RESPONSE PLEASE HAVE THE MODEL
NUMBER AND DATE OF PURCHASE AVAILABLE. A CUSTOMER
SERVICE REPRESENTATIVE WILL TAKE YOUR CALL AND
ANSWER ANY QUESTIONS YOU MAY HAVE RELATING TO THE
WARRANTY POLICY OR PROCEDURE.
OZITO INDUSTRIES PTY. LTD. 25 Fox Drive, Dandenong South, Victoria, Australia 3175.
The benets provided under this warranty are in addition to other rights and
remedies which are available to you at law.
Our goods come with guarantees that cannot be excluded at law. You are entitled to
a replacement or refund for a major failure and for compensation for any other
reasonably foreseeable loss or damage. You are also entitled to have the goods
repaired or replaced if the goods fail to be of acceptable quality and the failure
does not amount to a major failure.
Generally you will be responsible for all costs associated with a claim under this
warranty, however, where you have suffered any additional direct loss as a result of
a defective product you may be able to claim such expenses by contacting our
customer service helpline above.
WARNING
The following actions will result in the warranty being
void.
If the tool has been operated on a supply voltage other than that specied
on the tool.
If the tool shows signs of damage or defects caused by or resulting from
abuse, accidents or alterations.
Failure to perform maintenance as set out within the instruction manual.
If the tool is disassembled or tampered with in any way.
5 YEAR REPLACEMENT WARRANTY
Your Product is guaranteed for a period of 60 months from the original date of
purchase and is intended for DIY (Do It Yourself) use only. If a product is defective it
will be replaced in accordance with the terms of this warranty. Lithium Ion
batteries and chargers are covered by a 36 month
warranty and are excluded from the warranty extension. Warranty excludes
consumable parts.
ONLINE MANUAL
Scan this QR Code with your
mobile device to take you to
the online manual.
MANUAL
AUTO
PSI KPA
BAR
-
+
BAR
Attaching Inflation Adaptors
The inator unit has 3 adaptors to allow a range of functions.
1. Unlock the nozzle by lifting the locking
lever.
3. Insert the adaptor into the hose
nozzle and lock by pushing down
the locking lever.
Note: When not in use, the
ination adaptors can be stored in
the slots on the tool.
1. Pressure Mode Button
2. Preset Pressure
3. Current Pressure
4. Pressure Selection Buttons
5. Pressure Hose Storage Slot
6. Adaptor Storage
7. Manual / Auto Switch
8. Battery Seating
9. Hose Nozzle
10. High Pressure Hose
11. Presta Adaptor
12. General Purpose Adaptor
13. Ball Adaptor
This tool is compatible with all batteries & chargers from the Ozito Power X Change
range.
HIGH PRESSURE AIR INFLATOR
BATTERY & CHARGER
KNOW YOUR PRODUCT
1. CONNECTING ACCESSORIES
SETUP & PREPARATION
10
1
2
3
4
7
8
5
6
11
9
12 13
WARNING! ENSURE THE TOOL IS SWITCHED
OFF AND THE BATTERY IS REMOVED BEFORE
PERFORMING ANY OF THE FOLLOWING TASKS.
a
b
Switching The Unit On/Off
1. Press the manual/auto trigger to
start the inator; the display will
light up.
2. Press and hold the pressure mode button for 2
seconds. The tool and display will shut off.
Note: The inator will switch off automatically
after approximately 5 minutes of inactivity; the
display will also power down.
Presetting The Pressure
1. Press the pressure mode button
to toggle between the 3 pressure
units (bar, psi or kPa).
2. Increase the preset pressure using the “+”
button or decrease the pressure using the
“-” button.
The preset pressure will be displayed on
the digital display as it is adjusted.
Digital Display
The upper value on the screen shows
the preset pressure.
The lower value on the screen
displays the pressure of the
connected item as it is being
inated.
Note: If the connected item is already partially inated, the existing
pressure will be registered on the display when connected.
WARNING! DO NOT LEAVE UNATTENDED WHILST
THE TOOL IS IN OPERATION.
Installing The Battery Pack
1. Slide the battery into the tool
base until it clicks into place.
Removing The Battery Pack
1. Hold down the battery release
button and then slide the battery
out.
2. FITTING THE BATTERY 3. CONTROLS
OPERATION
M
AUTO
MANUAL
AUTO
BAR
BAR
PRESET
PRESSURE
CURRENT
PRESSURE
PSI KPA
BAR
BAR
PSI KPA
BAR
HOLD
BAR
-
+
BAR
MANU
AUTO

Specyfikacje produktu

Marka: Ozito
Kategoria: Niet gecategoriseerd
Model: PXHPCK-250

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z Ozito PXHPCK-250, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje Niet gecategoriseerd Ozito

Ozito

Ozito PXJBS-0182 Instrukcja

14 Września 2024
Ozito

Ozito PXCTS-0182U Instrukcja

13 Września 2024
Ozito

Ozito PXHVIS-018 Instrukcja

13 Września 2024
Ozito

Ozito PXBC-004U Instrukcja

10 Września 2024
Ozito

Ozito PXBLTS-018 Instrukcja

10 Września 2024
Ozito

Ozito GGK-030 Instrukcja

5 Września 2024
Ozito

Ozito RSH-100 Instrukcja

3 Września 2024
Ozito

Ozito AAHR-090 Instrukcja

30 Sierpnia 2024
Ozito

Ozito OJS-800 Instrukcja

27 Sierpnia 2024
Ozito

Ozito PXBVK-4182 Instrukcja

26 Sierpnia 2024

Instrukcje Niet gecategoriseerd

Najnowsze instrukcje dla Niet gecategoriseerd