GUIDE SPECIFICATIONS
On-Q® Residential Multimedia Panels
Project Name Project No. Date
Project Location -1 Communications Cabinets, Racks, Frames, 27 11 16
& Enclosures
This guide specication is written according to the Construction Specications Institute (CSI)
formats, including MasterFormat, SectionFormat, and PageFormat.
Carefully review and edit this section to meet the requirements of the project and local building
code. Coordinate this section with other specication sections and drawings.
Delete all "Specier Notes" when done editing this section.
SECTION 27 11 16
COMMUNICATIONS CABINETS, RACKS, FRAMES, AND ENCLOSURES
PART 1 - GENERAL
1.1 CONDITIONS AND REQUIREMENTS
A. The General Conditions, Supplementary Conditions, and Division 0 General 1
Requirements apply.
1.2 SECTION INCLUDES
Specier Note: Delete items below that are not included in this section.
A. Residential multimedia panels (MMP).
B. [Insert item description.]
1.3 RELATED SECTIONS
Specier Note: In this article, specify work specied in other sections that is related to work
of this section.
A. Division 2 - Electrical: Electrical systems and components. 6
B. Division - Communications: Communications and audio- systems and 27 video
components.
C. Division - Electronic Safety and Security: Security systems and components. 28
Specier Note: The following paragraph is a sample that may be used in this article. Add to
or delete from the following as appropriate for the specic project.
D. Section [ xx xx [Section Title]: [Include brief description of work specied in xx ]
another section that is related to the work of this section.]
1.4 SUBMITTALS
Specier Note: In this article, specify various types of data to be furnished by the contractor
before, during, or after construction. Topics included in this article are: product data, shop
drawings, samples, design data, test reports, certificates, manufacturers’ instructions, manu-
facturers’ field reports, qualification statements, and closeout submittals.
A. Submit under provisions of Section [01 00] [______]. 33
B. Product Data: Submit for residential multimedia panels and components.
C. Shop Drawings: For the following electrical system components. Include plans,
elevations, sections, details, and attachments to other work.
1. Residential multimedia panels.
GUIDE SPECIFICATIONS
On-Q® Residential Multimedia Panels
Project Name Project No. Date
Project Location -2 Communications Cabinets, Racks, Frames, 27 11 16
& Enclosures
D. Samples: Submit three (3) [___________] with required color and nish. Show
standard color ranges available.
1.5 QUALITY ASSURANCE
Specier Note: In this article, describe qualications, regulatory requirements, certications,
eld samples, mock-ups, and pre-installation meetings.
A. Manufacturers: Firms regularly engaged in manufacture of residential multimedia
panels components of the types and sizes required, whose products have been in and
satisfactory use in similar service for not less than 10 years. Provide residential
multimedia panels components produced by a manufacturer listed in this section. and
B. Source Limitations: Obtain each type of residential multimedia panel components and
through one (1) source from a single manufacturer.
C. Residential Multimedia Panels and Components: Comply with requirements of
applicable local codes, NEC, UL, ETL, EIA, TIA, and NEMA Standards pertaining to
residential multimedia panels components UL and/or cUL classied. Comply with and .
NFPA 70.
1.6 DELIVERY, STORAGE AND HANDLING
A. Deliver residential multimedia panels and components in factory labeled packages.
B. Store and handle in strict compliance with manufacturer’s written instructions and
recommendations.
C. Protect from damage due to weather, excessive temperature, and construction
operations.
PART 2 - PRODUCTS
2.1 MANUFACTURERS
A. Basis- -Design Product: The design for residential multimedia panels is based on of
products manufactured by Legrand
®, , , 301 Fulling Mill Rd Suite G, Middletown PA
17057 21; toll-free 800-3 -2343; Web Site: http://www.legrand.us/onq.
B. Substitutions will be considered under provisions of Section 25 . 01 00
2.2 RESIDENTIAL MULTIMEDIA PANELS (MMP)
A. Residential Multimedia Panels, General: -QOn ® Residential Multimedia Panels (MMP)
provide a central distribution point for home or small oce technologies. The
enclosures accommodate distribution of voice, data, video, audio, security, and control
applications.
B. Metal Enclosures, General: Fabricated from 20 gauge cold-rolled steel with protective
powder coat nish, glossy white color and provided with matching hinged anged cover
with lock.
1. Mounting slots on enclosure permit adjustment for dierent gypsum board
thicknesses. Provide 1/2-inch, 5/8-inch, and 3/4-inch depth marks on enclosure
for alignment.
2. Lance slots within enclosure for hook- -loop fastener or vinyl cable ties. and
3. Flush mount cover overlaps 3/4-inch to hide gypsum board cuts around the
MMP.
GUIDE SPECIFICATIONS
On-Q® Residential Multimedia Panels
Project Name Project No. Date
Project Location -3 Communications Cabinets, Racks, Frames, 27 11 16
& Enclosures
4. Enclosure ships with cardboard insert to prevent debris or paint over-spray from
entering the MMP during rough-in stage of installation.
5. Provide mounting hooks on cover to align screw holes for ease of installation.
6. Multiple knockouts on enclosure support conduit up to two (2) inches in diameter
and facilitate cable routing and entry.
7. Holds 1/4, 1/2 and full-width expansion modules with ability to mount most
modules either vertically or horizontally.
8. Provide for bonding and grounding to meet TIA/EIA 606 Standards.
9. Conformance with Standards: Comply with TIA/EIA 568-A and TIA/EIA 570-A
requirements and meet FCC Part 68.
10. Enclosure to be UL listed in accordance with ANSI/UL 985, ANSI/UL 1023,
CAN/CSA-C22.2 No. 182.4-1990, ULC-S545, and CSA-C22.2 No. 144.1 (2006).
Specier Note: Enclosure size, data module, voice module, and video module selection will
depend on application variables, such as ber or copper, Cat , Cat 6, or Cat 6a, size of 5e
residence, etc. Retain as many of t following ve (5) enclosures as required for a specic he
project and delete the others.
Specier Note: The enclosures in the ve (5) paragraphs can accommodate a variety of
modules. Select desired modules from Article 2.3 below.
Specier Note: The 14"-42" metal enclosures the ve (5) paragraphs below are also available
with screw on doors (ENXX00), enclosure only (ENXX80), hinged cover only (ENXX60),
screw on cover only (ENXX20), and an enclosure with knockouts (ENXX85). Revise the cata-
log number and description accordingly to reect the type of enclosure desired.
C. Metal Enclosures:
1. 42" Enclosure: Catalog No. EN4250 enclosure with hinged cover and lock;
minimum dimensions shall be 42" H x 14. " W x 3.6" D. 25
2. 28" Enclosure: Catalog No. EN2850 enclosure with hinged cover and lock;
minimum dimensions shall be 28" H x 14.25" W x 3.6" D.
3. 20" Enclosure: Catalog No. EN2050 enclosure with hinged cover and lock;
minimum dimensions shall be 20" H x 14.25" W x 3.6" D.
4. 14" Enclosure: Catalog No. EN1450 enclosure with hinged cover and lock;
minimum dimensions shall be 14" H x 14. " W x 3.6" D. 25
D. Plastic Enclosures for General Structured Wiring, General: Fabricated from UL-rated
ABS plastic, paintable white color and provided with matching hinged anged cover.
Enclosure accommodates both wired structured wiring systems and wireless
networking equipment. Complies with UL60950-1 and CAN/CSA C22.2 No. 60950- -01
07. RoHS Compliant.
1. Plastic enclosure allows wireless devices such as access points to secure in
cabinet without degrading network performance.
2. Enclosure can be surface or ush mounted. Staggered tabs allow side- -side by
installation of multiple enclosures.
3. Meets or exceeds requirements of UL Standard 2416. For use in non-re-rated
walls.
4. Universal mounting grid compatible with distribution modules from multiple
manufacturers.


Specyfikacje produktu

Marka: On-Q
Kategoria: Niesklasyfikowane
Model: RJ45

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z On-Q RJ45, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje Niesklasyfikowane On-Q

On-Q

On-Q AC1068 Instrukcja

28 Września 2024
On-Q

On-Q AC3607BEV1 Instrukcja

22 Września 2024
On-Q

On-Q LC7001 Instrukcja

21 Września 2024
On-Q

On-Q 36490401 Instrukcja

21 Września 2024
On-Q

On-Q F7417LA Instrukcja

21 Września 2024
On-Q

On-Q WP1234WH Instrukcja

21 Września 2024
On-Q

On-Q RJ45 Instrukcja

20 Września 2024
On-Q

On-Q ENP3050-NA Instrukcja

20 Września 2024
On-Q

On-Q F7417WH Instrukcja

20 Września 2024
On-Q

On-Q ENP4201 Instrukcja

20 Września 2024

Instrukcje Niesklasyfikowane

Najnowsze instrukcje dla Niesklasyfikowane

Stihl

Stihl HT 70 Instrukcja

15 Października 2024
Ernesto

Ernesto H14270 Instrukcja

15 Października 2024
Uniden

Uniden BT MIC KIT Instrukcja

15 Października 2024
Vaude

Vaude Omnis Bike 26 Instrukcja

15 Października 2024
ART

ART ProChannel II Instrukcja

15 Października 2024
Aukey

Aukey DR02J Instrukcja

15 Października 2024
Master Lock

Master Lock 653EURD Instrukcja

15 Października 2024
Roland

Roland FR-18 Diatonic Instrukcja

15 Października 2024