BUILT–IN UNIT INSTRUCTION GUIDE
Please use this manual in conjuncon with your main manual to properly assemble your built-in grill. Refer to
the main manual for operang, cleaning, and maintenance instrucons.
WARNING! This grill is designed for enclosures only, and must be installed and

WARNING!
BUILT IN PROPANE GAS HOOK-UP: The piping up to the gas grill is the responsibility of the installer and piping
should be located as shown in the built-in instrucons. A exible metal connector is included to simplify the
installaon of the unit. Connect this exible metal connector to the are ng on the end of the manifold.
Connect the other end of the connector to the gas piping. Ensure that the connector does not pass through a
wall, oor, ceiling or paron, and is protected from damage. Do not use a hose to connect the unit except to
connect the cylinder regulator to the piping system. It must be connected with rigid pipe, copper tube or an
approved exible metal connector which complies with Z21.4 /CSA 6.10.
The installaon must comply with CAN B149.1 Natural Gas and Propane installaon code in Canada, or to the
Naonal Fuel Gas code, ANSI Z223.1 in the United States. The gas supply pipe must be suciently sized to
supply the BTU/h specied on the rang plate, based on the length of the piping run. If installing a side burner,
a separate line must be branched o to the side burner unit and enter the side burner opening at the specied
locaon. If the enclosure is to house a propane cylinder, the tank poron of the enclosure must be venlated
according to local codes, and must not have communicaon with the cavity used to enclose the gas grill. A
propane tank can not be stored below the gas grill.
BUILT IN CYLINDER ENCLOSURES: Built in cylinder enclosures which completely enclose the cylinder must have
both of the following:
1. At least one unobstructed venlaon opening on the exposed exterior side of the enclosure located within
5 in (127 mm) of the top of the enclosure. The opening must have a total free area of more than 20 in
2
(130
cm2)
for a 20 lb (9.1 kg) cylinder and 30 in2 (195 cm2) for a 30 lb (13.6 kg) cylinder.
2. At least one venlaon opening on the exposed, exterior side of the enclosure located 1 in (25.4 mm) or less
from the oor level. The opening must have a total free area of more than 10 in 2 (65 cm2) for a 20 lb (9.1 kg)
cylinder and 15 in2 (100 cm2) for a 30 lb (13.6 kg) cylinder. The upper edge must be no more than 5 in (127
mm) above the oor level.

www.napoleongrills.com
Napoleon Group of Companies



WARNING!
The cylinder valve(s) must be readily accessible for hand operaon. A door on the enclosure to gain access
to the cylinder valves is acceptable, provided it is non-locking and can be opened without the use of tools.
The enclosure for the LP-gas cylinder must isolate the cylinder from the burner compartment to provide
shielding from radiaon, a ame barrier, and protecon from foreign material, such as hot drippings. The
enclosure cannot be located directly below the grill.
There must be a minimum clearance of 2 in (51 mm) between the oor of the LP-gas cylinder enclosure
and the ground.
The enclosure must be designed so that the LP-gas cylinder can be connected, disconnected and the
connecons inspected and tested outside the cylinder enclosure. Any connecons that can be disturbed
when installing the cylinder in the enclosure must be accessible for tesng inside the enclosure.
BUILT IN NATURAL GAS HOOK-UP: The piping up to the gas grill is the responsibility of the installer and piping
should be located as shown in the built-in instrucons. A exible metal connector is included to simplify the
installaon of the unit. Connect this connector to the are ng on the end of the manifold. Connect the
other end of the connector to the gas piping. Ensure that the connector does not pass through a wall, oor,
ceiling or paron, and is protected from damage. Do not use hose to connect the unit. It must be connected
with rigid pipe, copper tube or an approved exible metal connector which complies with Z21.4 /CSA 6.10.
The installaon must comply with CAN B149.1 Natural Gas and Propane Installaon Code in Canada, or to the
Naonal Fuel Gas Code, ANSI Z223.1 in the United States. The gas supply pipe must be suciently sized to
supply the BTU/h specied on the rang plate, based on the length of the piping run. If installing a side burner,
a separate line must be branched o to the side burner unit and enter the side burner opening at the specied
locaon.
WARNING! Built in units are supplied with a drip pan which holds only a minimal amount of grease.
To prevent grease res, the pan must be cleaned aer each use.
WARNING! Access must be provided to the inside of the enclosure to make gas connecons.
DANGER! Read all instrucons carefully before operang the grill. Failure to follow these instrucons
exactly could result in a re causing serious injury or death. The enre installaon must be leak tested
before operang the grill.
CYLINDER SIZE OPENING A AREA OPENING B AREA
20 lb (9.1kg) 20in2 (130cm2)10in2 (65cm2)
30 lb (13.6kg) 30in2 (195cm2)15in2 (100cm2)
5” (127mm)
MAXIMUM
1” (25.4mm)
MAXIMUM
OPENING
A
OPENING
B2” (51mm)
MINIMUM
PARTITION TO ISOLATE
CYLINDER FROM GRILL
NON LOCKING DOOR
34” (864mm)
RECOMMENDED
5” (127mm)
MAXIMUM
3
www.napoleongrills.com
MINIMUM 10 SQ IN OF
VENTILATION REQUIRED
ON EACH END OF CABINET
34” (864mm)
RECOMMENDED
BUILT-IN UNIT OPENING DIMENSIONS
OUTDOOR GFI ELECTRICAL OUTLET
REC
OMMENDED - LOCATE ON LEFT
SIDE OF GRILL FOR ROTISSERIE USE.
BIU405 BUILT-IN GRILL HEADS
BUILT-IN SIDEBURNER
2” (51mm)
3”(76mm) MIN.
6”(152mm)
W
D
H
1¾”
(44mm)
1¾”
(44mm)
4”(102mm)
7”(178mm)
H
H
DD
W
W
GAS INLET OPENING GAS INLET OPENING GAS INLET OPENING
NON-COMBUSTIBLE MATERIAL
CABINET FRAME AND CABINET MUST BE MADE FROM
NON-COMBUSTIBLE MATERIAL
BIPT450 / BIPT600 / BIPT750 BUILT-IN
GRILL HEADS
MODEL OPENING DIMENSIONS NOTES
W D H
BIPT450 29 1/2”
749mm
20 5/8”
524mm
8 7/8”
225mm
BIPT600 37 3/4”
959mm
20 5/8”
524mm
8 7/8”
225mm
BIPT750 49 3/4”
1264mm
20 5/8”
524mm
9 5/8”
244mm
BIU405 27 1/2”
699mm
16 3/4”
425mm
12”
305mm
ACCESS MUST BE PROVIDED FOR DRIP TRAY REMOVAL AND
CLEANING.
SIDE BURNER 12 3/4”
324mm
16 1/2”
419mm
4 1/2”
114mm
OPENING OF AT LEAST 5 SQ IN MUST BE PROVIDED FOR
COMBUSTION AIR FOR SIDE BURNER.


Specyfikacje produktu

Marka: Napoleon
Kategoria: Rożen
Model: Gemini BIPT750RBI

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z Napoleon Gemini BIPT750RBI, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje Rożen Napoleon

Instrukcje Rożen

Najnowsze instrukcje dla Rożen

Barbecook

Barbecook Siesta 210 Instrukcja

12 Października 2024
Roesle

Roesle MAGNUM PRO G3 Instrukcja

9 Października 2024
Roesle

Roesle No.1 F60 AIR Instrukcja

9 Października 2024
Roesle

Roesle Videro G4 Instrukcja

9 Października 2024
XO

XO GPOWER60K Instrukcja

8 Października 2024