The Signature Series is designed for amateur installation. NOT Installation SHOULD be performed by an authorized technician.
Please read this manual carefully before installation and keep it for future reference.
The Signature Series is designed for amateur installation. NOT Installation SHOULD be performed by an authorized technician.
Please read this manual carefully before installation and keep it for future reference.
Installation Manual
Signature Series
MAC16*A A/C SPLIT SYSTEM
507043-04C Page 1 of 9mrcool.com
Save these instructions for future reference
INSTALLATION INSTRUCTIONS
MAC16*A A/C SPLIT SYSTEM
(P) 507043-04C
*P507043-04C*
Manufactured By
MRCOOL, LLC
Hickory, KY 42051
This manual must be left with the homeowner for future reference.
This is a safety alert symbol and should never be ignored. When you see this symbol on labels or in
manuals, be alert to the potential for personal injury or death.
Improper installation, adjustment, alteration, service
or maintenance can cause property damage, personal
injury or loss of life. Installation and service must be
performed by a licensed professional installer (or
equivalent), service agency or the gas supplier.
WARNING
result in hazards to you and others. Installation MUST
conform with local building codes and with the National
Electric Code NFPA 70/ANSI C1-1993 or current edition
and Canadian Electrical Code Part 1 CSA .
WARNING
Table of Contents
Safety Precautions ......................................................2
Installation ...................................................................2
Electrical Connections.................................................4
Start-Up Procedure......................................................5
System Operation........................................................6
Homeowner’s Information ...........................................9
These instructions are intended as a general guide and
do not supersede national, state or local codes in any
way.
These instructions must be left with the property owner.
NOTE
These instructions and warranty are to be given to the
owner or prominently displayed near the indoor air
handler unit.
NOTE TO INSTALLING DEALER
Page 2 of 9 507043-04Cmrcool.com
These units are designed for use in residential and
commercial type buildings. Units should be installed
with combinations listed in the Air-Conditioning, Heating
Products. Refer to http://www.ahridirectory.org.
Before installation, inspect the unit for shipping damage.
If damage is found, notify the transportation company
Before installing, modifying, or servicing system, main
electrical disconnect switch must be in the OFF position.
There may be more than 1 disconnect switch. Lock out
and tag switch with a suitable warning label. Electrical
shock can cause personal injury or death.
WARNING
Safety Precautions
Follow all safety codes. Wear safety glasses and work
gloves. Use quenching cloth for brazing operations.
thoroughly and follow all warning or cautions attached to
the unit.
1. Always wear proper personal protection equipment.
2. Always disconnect electrical power before removing
panel or servicing equipment.
3. Keep hands and clothing away from moving parts.
4. Handle refrigerant with caution, refer to proper MSDS
from refrigerant supplier.
5. Use care when lifting, avoid contact with sharp edges.
Installation
Unit Location
NOTE: In some cases noise in the living area has been
traced to gas pulsations from improper installation of
equipment.
1. Locate unit away from windows, patios, decks, etc.
where unit operation sounds may disturb customer.
2. Ensure that vapor and liquid tube diameters are
appropriate to capacity of unit.
3.
unecessary turns and bends.
4. Leave some slack between structure and unit to
absorb vibration.
5. When passing refrigerant tubes through the wall, seal
opening with RTV or other silicon-based caulk.
6. Avoid direct tubing contact with water pipes, duct work,
7. Do not suspend refrigerant tubing from joists and
studs with a rigid wire or strap which comes in direct
contact with tubing.
8. Ensure that tubing insulation is pliable and completely
surrounds suction line.
When outdoor unit is connected to factory-approved indoor
unit, outdoor unit contains system refrigerant charge for
operation with indoor unit of the same size when connected
check refrigerant charge using charging information
located on control box cover.
NOTE: Maximum liquid-line size is 3/8 in. O.D. for all
residental applications including long lines.
Outdoor Section
Zoning ordinances may govern the minimum distance the
condensing unit can be installed from the property line.
Install on a Solid, Level Mounting Pad
The outdoor section is to be installed on a solid foundation.
This foundation should extend a minimum of 2” (inches)
beyond the sides of the outdoor section. To reduce the
possibility of noise transmission, the foundation slab
should be in contact with or be an integral part of the NOT
building foundation.
If conditions or local codes require the unit be attached to
pad or mounting frame, tie down bolts should be used and
fastened through knockouts provided in unit base pan.
Rooftop Installations
Mount on level platform or frame 6 inches above roof
surface. Place unit above a load-bearing wall and isolate
unit and tubing set from structure. Arrange supporting
members to adequately support unit and minimize
transmission of vibration to building. Ensure roof structure
and anchoring method is adequate for location. Consult
local codes governing rooftop applications.
NOTE: Unit must be level to within ± 1/4 in./ft per
Clearance Requirements
snow, or ice from roof or eaves cannot fall directly on unit.


Specyfikacje produktu

Marka: MRCOOL
Kategoria: klimatyzacja
Model: MAC16030A

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z MRCOOL MAC16030A, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje klimatyzacja MRCOOL

MRCOOL

MRCOOL PTAC12335 Instrukcja

22 Września 2024
MRCOOL

MRCOOL MAHM030ETA Instrukcja

22 Września 2024
MRCOOL

MRCOOL MAHM042ETA Instrukcja

22 Września 2024
MRCOOL

MRCOOL MAHM048ETA Instrukcja

22 Września 2024
MRCOOL

MRCOOL PTHP15335 Instrukcja

21 Września 2024
MRCOOL

MRCOOL MAHM036CTA Instrukcja

21 Września 2024
MRCOOL

MRCOOL MAC16018A Instrukcja

21 Września 2024
MRCOOL

MRCOOL MAC16042A Instrukcja

21 Września 2024
MRCOOL

MRCOOL MAHM048CTA Instrukcja

21 Września 2024

Instrukcje klimatyzacja

Najnowsze instrukcje dla klimatyzacja

LG

LG HS-H076QPA0 Instrukcja

15 Października 2024
Klarstein

Klarstein Vita Pure 2G Instrukcja

15 Października 2024
Gree

Gree ETAC-15HP265V20B Instrukcja

15 Października 2024
Qlima

Qlima P 126 Instrukcja

14 Października 2024
Mitsubishi

Mitsubishi MSZ-CB22VA Instrukcja

14 Października 2024
Suntec

Suntec Motion 90+ Instrukcja

14 Października 2024
Danby

Danby DTAC120B1WDB Instrukcja

14 Października 2024
Amana

Amana PTC093K35AXXX Instrukcja

14 Października 2024
Amana

Amana AMAP121AB-2 Instrukcja

14 Października 2024