Serial Port Powered Media Conversion Solution
TCC-82 User’s Manual P/N: 1802000820012 Fourth Edition.
www.moxa.com ©2010 Moxa Inc.
Moxa Inc. All rights reserved.
RS-232 Pinouts
The female DB9 port and RS-232 pinouts for the
port are shown below.
54321
9 68 7
PIN RS-232
1 DCD
2 TxD
3 RxD
4 DSR
5 GND
6 DTR
7 CTS
8 RTS
The male DB9 port and RS-232 pinouts for the port
are shown below.
12345
6789
PIN RS-232
1 DCD
2 RxD
3 TxD
4 DTR
5 GND
6 DSR
7 RTS
8 CTS
Note: The DTR, DSR and DCD pins are shorted
as shown above so that users do not need
to worry about signal control cable wiring.
TCC-82 V2.0
4-channel, self-powered RS-232 signal isolator
(4KV RMS for 1 min. isolation) with 15 KV ESD
protection
Overview
The TCC-82 is a signal isolator that provides
bi-directional serial communication with full
electrical isolation between two RS-232 devices.
This compact isolator isolates both sides of the
connection, providing perfect protection from
ground loops, lightning surge coupling, and
accidental high voltage shorts. The internal
magnetic coupler is tested to ensure that it can
withstand more than 4 KV rms input-to-output for 1
minute. This guarantees that the TCC-82 not only
meets the requirements of general serial data
communications, but also the high standards
required by industrial automation and medical
applications. In addition to the TxD and RxD data
lines, the TCC-82 also protects the RTS/CTS
handshake lines on its two D-type connectors.
Package Checklist
TCC-82 RS-232 Signal Isolator
2 USB Power Cords
Users Manual
Applications
Medical facilities
Terminal connections
Factory automation
Remote serial device control
Building security automation
Critical industrial control
Surveillance systems
Features and Specifications
Serial interface: RS-232
Serial port type: DB9 (1 male, 1 female)
Compact size
Auto senses baud rates up to 115.2 Kbps
Signals:
RS-232 Isolation: TxD, RxD, RTS and CTS;
RS-232 loop back: DTR to DSR and DCD
15 KV ESD protection for all RS-232 signals
Serial Power Source: TxD, RTS, or DTR
External Power (jack connector): DC +5V to
+12V adaptors or by USB power cords.
Operating temperature: 0 to 60°C (32 to 140°F)
Dimensions: 42 x 80 x 23.6 mm
Casing: ABS + PC
Weight: 60 ± 5g
CE, FCC Class B approval
Power Consumption: 20 mA at +5 VDC
Warranty: 5 years
shorted
shorted
TCC-82 User’s Manual TCC-82 User’s Manual
Installation
Independent Serial Port Power
TCC-82 has two power inputs, which means that
both sides of the isolator must be powered
independently and separately to maintain the
isolation. Ideally, both sides can get power directly
from the RS-232 TxD data lines and the RTS/DTR
handshake lines, regardless of whether the signal is
high or low. This also eliminates the need to use
external power supplies for most systems. The
configuration of the wires and the entire system can
be maintained easily.
In most situations, the TCC-82 can get enough
power from the attached Tx line. If the attached
serial device does not provide enough power
through the Tx line, additional handshake lines can
used to power the TCC-82.
Implementing External Power
When connecting the TCC-82, all output signals
should be connected, since the TCC-82 derives
power from these signals, even if they are not used
by your system to transmit data signals. Care should
be taken when implementing the external power
supply. Usually, one side of the TCC-82 is attached
to the host PC by a short serial cable. On the other
side, the serial cable may be too long and the power
from the remote device will not be sufficient to
activate the other end of the TCC-82. Refer to the
following figure to see an example that implements
external power.
It is also important to use the external power supply
if the TCC-82’s full 4 KV of isolation is required to
operate correctly. Most of the commercial power
supplies that are available on the market only
provide 1500 VAC or less of isolation between the
primary and secondary windings. If both sides of
the isolator require external power, then two
separate isolated 4 KV protected power supplies are
required.
NOTE: Be sure to connect the two power adaptors
to different power channels.
Using different power inputs for the two power
channels is an integral part of the isolation design.
DO NOT implement your power system as follows:
Compatibility of Serial Interfaces
Different kinds of serial ports use different interface
chips, and provide different power levels. In fact,
some ports will not provide enough power to
activate the TCC-82.
You will seldom encounter problems with a PC’s
onboard COM1 and COM2 ports. Refer to the
following table for add-on cards and
serial-to-Ethernet device server that are guaranteed
to provide sufficient power.
Multiport Serial Boards Serial Device Servers
Moxa Boards
CP-168U Series
CP-104U Series
CP-102U Series
C168H Series
C104H Series
Moxa NPort Servers
CN2510
CN2610
NPort5110
NPort5210
NPort5410
NPort5610
NPort6150
NPort6250
NPort6450
NPort6650
Optional USB Power Cord
If additional external power is required, the TCC-82
can be connected to a standard 5 to 12 VDC power
supply, or a USB power cord.
CBL-USBAP-50
USB “A” Male Connector
Front:
4 3 2 1
Top:
TCC-82 USB Connector
Connector Pinouts Signals
1 +5 VDC
2 --
3 --
4 GND
28-CCT
renni
retuo
gulP rewoP CD
05-PABSU-LBC
BSU tsoH BSU
elameF epyT A
CDV 5+
DNG
gniriW elbaC
1
4
12 VDC
10 mA (max.)
Ø2.1±0.1
Ø5.1±0.1


Specyfikacje produktu

Marka: Moxa
Kategoria: Niesklasyfikowane
Model: TCC-82-RP

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z Moxa TCC-82-RP, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje Niesklasyfikowane Moxa

Moxa

Moxa OnCell G3150 Instrukcja

24 Września 2024
Moxa

Moxa 4101I-MB-PBS Instrukcja

24 Września 2024
Moxa

Moxa ICF-1150I-M-ST Instrukcja

24 Września 2024
Moxa

Moxa ioLogik R1241 Instrukcja

24 Września 2024
Moxa

Moxa 4101-MB-PBS Instrukcja

24 Września 2024
Moxa

Moxa MGate EIP3270 Instrukcja

24 Września 2024
Moxa

Moxa M-1600 Instrukcja

24 Września 2024
Moxa

Moxa TCC-80-RP Instrukcja

24 Września 2024
Moxa

Moxa TCC-82-RP Instrukcja

24 Września 2024

Instrukcje Niesklasyfikowane

Najnowsze instrukcje dla Niesklasyfikowane

Stihl

Stihl HT 70 Instrukcja

15 Października 2024
Ernesto

Ernesto H14270 Instrukcja

15 Października 2024
Uniden

Uniden BT MIC KIT Instrukcja

15 Października 2024
Vaude

Vaude Omnis Bike 26 Instrukcja

15 Października 2024
ART

ART ProChannel II Instrukcja

15 Października 2024
Aukey

Aukey DR02J Instrukcja

15 Października 2024
Master Lock

Master Lock 653EURD Instrukcja

15 Października 2024
Roland

Roland FR-18 Diatonic Instrukcja

15 Października 2024