Instrukcja obsługi Mitsubishi MSZ-GE71VA
Mitsubishi
Airco
MSZ-GE71VA
Przeczytaj poniżej 📖 instrukcję obsługi w języku polskim dla Mitsubishi MSZ-GE71VA (12 stron) w kategorii Airco. Ta instrukcja była pomocna dla 4 osób i została oceniona przez 2 użytkowników na średnio 4.5 gwiazdek
Strona 1/12
SPLIT-TYPE AIR CONDITIONERS
INDOOR UNIT
MSZ-GE60VA MSZ-GE71VA MSZ-GE80VA
English
OPERATING INSTRUCTIONS For user
• To use this unit correctly and safely, be sure to read these operating in-
structions before use.
En-1
● OPERATING INSTRUCTIONS ●
WARNING
Do not connect the power cord to an intermediate point,
use an extension cord, or connect multiple devices to a
single AC outlet.
• This may cause overheating, fi re, or electric shock.
Make sure the power plug is free of dirt and insert it se-
curely into the outlet.
• A dirty plug may cause fi re or electric shock.
Do not bundle, pull, damage, or modify the power cord, and
do not apply heat or place heavy objects on it.
• This may cause fi re or electric shock.
Do not turn the breaker OFF/ON or disconnect/connect the
power plug during operation.
• This may create sparks, which can cause fi re.
• After the indoor unit is switched OFF with the remote con-
troller, make sure to turn the breaker OFF or disconnect the
power plug.
Do not expose your body directly to cool air for a prolonged
length of time.
• This could be detrimental to your health.
The unit should not be installed, relocated, disassembled,
altered, or repaired by the user.
• An improperly handled air conditioner may cause fi re, electric
shock, injury, or water leakage.
This appliance is not intended for use by persons (including
children) with reduced physical, sensory or mental capabili-
ties, or lack of experience and knowledge, unless they have
been given supervision or instruction concerning use of the
appliance by a person responsible for their safety.
Children should be supervised to ensure that they do not
play with the appliance.
• Since rotating parts and parts which could cause an electric shock are used
in this product, be sure to read these “Safety Precautions” before use.
• Since the cautionary items shown here are important for safety, be sure to
observe them.
• After reading this manual, keep it together with the installation manual in a
handy place for easy reference.
• Be sure to receive a guarantee card from your dealer and check that the
purchased data and shop name, etc. are entered correctly.
Marks and their meanings
WARNING : Incorrect handling could cause serious hazard, such as
death, serious injury, etc. with a high probability.
CAUTION : Incorrect handling could cause serious hazard depending
on the conditions.
Do not insert your fi nger, a stick, or other objects into the
air inlet or outlet.
• This may cause injury, since the fan inside rotates at high
speeds during operation.
In case of an abnormal condition (such as a burning smell),
stop the air conditioner and disconnect the power plug or
turn the breaker OFF.
• A continued operation in the abnormal state may cause a
malfunction, fi re, or electric shock. In this case, consult your
dealer.
When the air conditioner does not cool or heat, there is
a possibility of refrigerant leakage. In this case, consult
your dealer. If a repair involves recharging the unit with
refrigerant, ask the service technician for details.
• The refrigerant used in the air conditioner is safe. Normally,
it does not leak. However, if refrigerant leaks and comes in
contact with a heat source such as a fan heater, kerosene
heater, or cooking stove, it will create a harmful gas.
CAUTION
Do not touch the air inlet or the aluminum fi ns of the
indoor/outdoor unit.
• This may cause injury.
Do not use insecticides or fl ammable sprays on the unit.
• This may cause a fi re or deformation of the unit.
Do not expose pets or houseplants to direct airfl ow.
• This may cause injury to the pets or plants.
Do not place other electric appliances or furniture under
the indoor/outdoor unit.
• Water may drip down from the unit, which may cause damage
or malfunction.
Do not leave the unit on a damaged installation stand.
• The unit may fall and cause injury.
Meanings of symbols used in this manual
: Be sure not to do.
: Be sure to follow the instruction.
: Never insert your fi nger or stick, etc.
:
Never step onto the indoor/outdoor unit and do not put anything on them.
: Danger of electric shock. Be careful.
: Be sure to disconnect the power supply plug from the power outlet.
: Be sure to shut off the power.
SAFETY PRECAUTIONS
CONTENTS
■ SAFETY PRECAUTIONS 1
■ NAME OF EACH PART 3
■ PREPARATION BEFORE OPERATION 3
■ SELECTING OPERATION MODES 4
■ FAN SPEED AND AIRFLOW DIRECTION ADJUSTMENT 5
■ LONG OPERATION 5
■ POWERFUL OPERATION 5
■ I-SAVE OPERATION 6
■ ECONO COOL OPERATION 6
■ TIMER OPERATION (ON/OFF TIMER) 6
■ WEEKLY TIMER OPERATION 7
■ C 8LEANING
■ WHEN YOU THINK THAT TROUBLE HAS OCCURRED 9
■ WHEN THE AIR CONDITIONER IS NOT GOING TO BE USED FOR A LONG TIME 10
■ INSTALLATION PLACE AND ELECTRICAL WORK 10
■ SPECIFICATIONS 10
En-2
CAUTION
Do not step on an unstable bench to operate or clean the
unit.
• This may cause injury if you fall down.
Do not pull the power cord.
• This may cause a portion of the core wire to break, which may
cause overheating or fi re.
Do not charge or disassemble the batteries, and do not
throw them into a fi re.
• This may cause the batteries to leak, or cause a fi re or explo-
sion.
Do not operate the unit for more than 4 hours at high hu-
midity (80% RH or more) and/or with windows or outside
door left open.
• This may cause the water condensation in the air conditioner,
which may drip down, wetting or damaging the furniture.
• The water condensation in the air conditioner may contribute
to growth of fungi, such as mold.
Do not use the unit for special purposes, such as storing
food, raising animals, growing plants, or preserving preci-
sion devices or art objects.
• This may cause deterioration of quality, or harm to animals
and plants.
Do not expose combustion appliances to direct airfl ow.
• This may cause incomplete combustion.
Before cleaning the unit, switch it OFF and disconnect the
power plug or turn the breaker OFF.
• This may cause injury, since the fan inside rotates at high
speeds during operation.
When the unit will be unused for a long time, disconnect the
power plug or turn the breaker OFF.
• The unit may accumulate dirt, which may cause overheating
or fi re.
Replace all batteries of the remote controller with new ones
of the same type.
• Using an old battery together with a new one may cause
overheating, leakage, or explosion.
If the battery fl uid comes in contact with your skin or clothes,
wash them thoroughly with clean water.
• If the battery fl uid comes in contact with your eyes, wash them
thoroughly with clean water and immediately seek medical
attention.
Ensure that the area is well-ventilated when the unit is oper-
ated together with a combustion appliance.
• Inadequate ventilation may cause oxygen starvation.
Turn the breaker OFF when you hear thunder and there is a
possibility of a lightning strike.
• The unit may be damaged if lightning strikes.
After the air conditioner is used for several seasons, per-
form inspection and maintenance in addition to normal
cleaning.
• Dirt or dust in the unit may create an unpleasant odor, con-
tribute to growth of fungi, such as mold, or clog the drain pas-
sage, and cause water to leak from the indoor unit. Consult
your dealer for inspection and maintenance, which require
specialized knowledge and skills.
WARNING
Consult your dealer for installing the air conditioner.
• It should not be installed by the user since installation requires
specialized knowledge and skills. An improperly installed air
conditioner may cause water leakage, fi re, or electric shock.
Provide a dedicated power supply for the air conditioner.
• A non-dedicated power supply may cause overheating or
fi re.
Do not install the unit where fl ammable gas could leak.
• If gas leaks and accumulates around the outdoor unit, it may
cause an explosion.
Earth the unit correctly.
• Do not connect the earth wire to a gas pipe, water pipe, light-
ning rod, or a telephone ground wire. Improper earthing may
cause electric shock.
CAUTION
Install an earth leakage breaker depending on the installa-
tion location of the air conditioner (such as highly humid
areas).
• If an earth leakage breaker is not installed, it may cause electric
shock.
Ensure that the drain water is properly drained.
• If the drain passage is improper, water may drip down from
the indoor/outdoor unit, wetting and damaging the furniture.
In case of an abnormal condition
Immediately stop operating the air conditioner and consult your dealer.
SAFETY PRECAUTIONS
Do not operate switches with wet hands.
• This may cause electric shock.
Do not clean the air conditioner with water or place an object
that contains water, such as a fl ower vase, on it.
• This may cause fi re or electric shock.
Do not step on or place any object on the outdoor unit.
• This may cause injury if you or the object falls down.
For installation
IMPORTANT
Dirty fi lters cause condensation in the air conditioner which will con-
tribute to the growth of fungi such as mold. It is therefore recommended
to clean air fi lters every 2 weeks.
Specyfikacje produktu
Marka: | Mitsubishi |
Kategoria: | Airco |
Model: | MSZ-GE71VA |
Potrzebujesz pomocy?
Jeśli potrzebujesz pomocy z Mitsubishi MSZ-GE71VA, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą
Instrukcje Airco Mitsubishi
14 Października 2024
9 Października 2024
8 Października 2024
8 Października 2024
8 Października 2024
8 Października 2024
8 Października 2024
4 Października 2024
4 Października 2024
2 Października 2024
Instrukcje Airco
- Airco Samsung
- Airco Electrolux
- Airco DeLonghi
- Airco AEG
- Airco Beko
- Airco LG
- Airco Gorenje
- Airco LERAN
- Airco Sharp
- Airco TCL
- Airco Russell Hobbs
- Airco Livoo
- Airco Dometic
- Airco Bosch
- Airco SHE
- Airco Candy
- Airco Whirlpool
- Airco Fujitsu
- Airco Ferroli
- Airco Midea
- Airco Kärcher
- Airco Hisense
- Airco Infiniton
- Airco Panasonic
- Airco Nedis
- Airco Be Cool
- Airco Medion
- Airco Black & Decker
- Airco Adler
- Airco Toshiba
- Airco Westinghouse
- Airco Rinnai
- Airco Domo
- Airco GE
- Airco Ardes
- Airco Taurus
- Airco Orbegozo
- Airco Blaupunkt
- Airco Vivax
- Airco Siemens
- Airco Danby
- Airco Einhell
- Airco Haier
- Airco Sigma
- Airco Jocel
- Airco Hyundai
- Airco Rowenta
- Airco Mesko
- Airco Master
- Airco Honeywell
- Airco Tripp Lite
- Airco Truma
- Airco Ozito
- Airco Hotpoint
- Airco Friedrich
- Airco Ariston Thermo
- Airco Zelmer
- Airco Wilfa
- Airco BLUEPALM
- Airco Amana
- Airco Furrion
- Airco Bomann
- Airco Emerio
- Airco Wood's
- Airco Create
- Airco InAlto
- Airco Daikin
- Airco Stirling
- Airco MPM
- Airco Philco
- Airco Corbero
- Airco Zanussi
- Airco Ravanson
- Airco Trotec
- Airco Thomson
- Airco Klarstein
- Airco Manta
- Airco Vaillant
- Airco Bavaria
- Airco Waeco
- Airco Camry
- Airco NewAir
- Airco Qlima
- Airco GUTFELS
- Airco TriStar
- Airco Bartscher
- Airco Dimplex
- Airco Baxi
- Airco Arçelik
- Airco Lavorwash
- Airco Gree
- Airco DCG
- Airco Daizuki
- Airco Sanyo
- Airco Clatronic
- Airco Telefunken
- Airco SVAN
- Airco IFB
- Airco Carson
- Airco Innoliving
- Airco Argoclima
- Airco Comfee
- Airco Bonaire
- Airco Meaco
- Airco Kenmore
- Airco VOX
- Airco Element
- Airco Orima
- Airco Aspes
- Airco Hitachi
- Airco Emerson
- Airco SereneLife
- Airco Frigidaire
- Airco EcoFlow
- Airco RCA
- Airco Climadiff
- Airco Electroline
- Airco Sencor
- Airco Mistral
- Airco Fuave
- Airco Kalorik
- Airco Avidsen
- Airco Suntec
- Airco Be Quiet!
- Airco Carrier
- Airco Geist
- Airco Daewoo
- Airco Livington
- Airco Consul
- Airco Zibro
- Airco Becken
- Airco Guzzanti
- Airco Tectro
- Airco Eurom
- Airco Sauber
- Airco Proline
- Airco Profile
- Airco Amcor
- Airco Argo
- Airco Tosot
- Airco Vestel
- Airco Itho
- Airco Mabe
- Airco Heinner
- Airco Eldom
- Airco Jocca
- Airco White Knight
- Airco Evolar
- Airco Elba
- Airco Royal Sovereign
- Airco Malmbergs
- Airco Listo
- Airco Daitsu
- Airco Milectric
- Airco Olimpia Splendid
- Airco Godrej
- Airco Maiko
- Airco Essentiel B
- Airco Equation
- Airco Edy
- Airco Maxicool
- Airco Dantherm
- Airco Carrefour Home
- Airco BOSFOR
- Airco MundoClima
- Airco Proklima
- Airco Home Electric
- Airco Eco-De
- Airco Aconatic
- Airco Duracraft
- Airco Khind
- Airco Hokkaido
- Airco Tarrington House
- Airco Evapolar
- Airco Orava
- Airco Kogan
- Airco Braemar
- Airco Klimaire
- Airco SEEGER
- Airco General Electric
- Airco SPT
- Airco Starlyf
- Airco Fuji Electric
- Airco Kibernetik
- Airco Companion
- Airco Prem-i-air
- Airco Bodin
- Airco AFINTEK
- Airco Brivis
- Airco MRCOOL
- Airco B-Air
- Airco Avallon
- Airco Protector
- Airco KwiKool
- Airco Arctic King
- Airco Climachill
- Airco Riffel
- Airco FREONIC
- Airco ARCTIC WIND
- Airco VänEE
- Airco Mayer
- Airco Perfect Aire
- Airco Koldfront
Najnowsze instrukcje dla Airco
14 Października 2024
14 Października 2024
14 Października 2024
14 Października 2024
14 Października 2024
14 Października 2024
14 Października 2024
14 Października 2024
14 Października 2024
14 Października 2024