IPS300/600/1000 (12/24V)
Pure Sine Wave Inverter
User Manual
IMPORTANT NOTICE:
This product is not intended to be use by children or persons in poor health without
supervision. Please read this manual thoroughly before use.
This manual is written for below models:
652.100UK - IPS300 12
652.101UK - IPS300- 24
652.102UK - IPS600- 12
652.103UK - IPS600- 24
652.104UK - IPS1000- 12
652.105UK - IPS1000-24
CAUTION:
Each model is design to work up to its maximum rated power load.
Please check carefully to ensure applications used are within the rated power range.
Any attempt of misuse to overload will trigger the overload protection and may cause
damage to both unit and application used. Mercury will not be responsible for any
damaged caused by misusage of the product
WARNING
Contain high voltage and high current! Do not open or
attempt to repair yourself!
User Manual
INTRODUTION:
Thank you for choosing this Pure Sine Wave Inverter. This inverter is capable of converting DC power
input to AC power output that has same output signal wave as normal domestic mains. Unlike modified
sine wave inverters, pure sine wave inverters will allow voltage sensitive or inductive equipment to work
flawlessly to it manufactured specification.
Below shows the differences in output voltage waveform between pure and modified output:
PRODUCT LAYOUT:
User Manual
FRONT PANEL:
- ON/OFF SWITCH rocker switch to switch unit on and off
- POWER INDICATOR solid green LED indicates unit has been switched on
- FAULT INDICATOR solid on or flashing red LED indicates fault has occurred,
refer to fault code for interpretation
- USB POWER SOCKET 5V 1.0A USB power supply socket for charging smart phone camera etc
- UK AC MAINS SOCKET output UK mains socket provide 230Vac 50Hz mains power
- GROUND CONNECTION star washer and nut for ground connection to the outer case (normally
connected to the vehicle chassis)
BACK PANEL:
- INPUT BATTERY NEGATIVE CONNECTION battery input connection to connect negative output
of the DC power source
- INPUT BATTERY POSITIVE CONNECTIO battery input connection to connect positive output of N
the DC power source
- FUSES location of the fuses
- FAN DUCT fan for cooling - do not obstruct
Temperature and load controlled multi-speed cooling fan:
The cooling fan is designed to run at a speed in proportion to the load, this minimises the running noise
and extend fan life.
- At load lower than 40% or inner temperature less than 30°C the fan will not operate
- At load between 40% - 60% the fan will operate at 40% of its maximum speed
- At load between 60% - 80% the fan will operate at 60% of its maximum speed
- At load between 80% - 100% the fan will operate at 80% of its maximum speed
- At 100% load or inner temperature exceeds 45°C the fan will operate at 100% of its maximum
speed
INSTALLATION:
Locati it is important to for the location of the inverter to meet below requirements: on
- Dry environment where there should be no risk of the inverter coming into contact with water
- A cool shaded environment where temperature should be 0°C 40°C,
not to be placed near any heat source and avoid direct sunlight
- A well-ventilated area, minimum clearance of two inches should be allowed in front of the
ventilation duct and fan. Please ensure free flow of air around the unit, if the unit is used to its full
load, an external fan may be used to aid the cooling of the unit
- Not to be place in the same compartment as the battery or together with flammable substances
- Avoid dusty environments, dust can cause blockage of airflow within the inverter
and cause the unit to overheat
- Avoid using long input cable run as input voltage can be affected by cable resistance and heat


Specyfikacje produktu

Marka: Mercury
Kategoria: Niesklasyfikowane
Model: IPS300

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z Mercury IPS300, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje Niesklasyfikowane Mercury

Mercury

Mercury MKA 1919 Instrukcja

8 Października 2024
Mercury

Mercury TLD Instrukcja

8 Października 2024
Mercury

Mercury ST-18 Instrukcja

8 Października 2024
Mercury

Mercury CMTS01 Instrukcja

3 Października 2024
Mercury

Mercury MTS01 Instrukcja

3 Października 2024
Mercury

Mercury DC1248UK Instrukcja

29 Września 2024
Mercury

Mercury USB-C224 Instrukcja

27 Września 2024
Mercury

Mercury UK2US45VA Instrukcja

18 Września 2024
Mercury

Mercury CB-R30 Instrukcja

17 Września 2024
Mercury

Mercury BAT402 Instrukcja

16 Września 2024

Instrukcje Niesklasyfikowane

Najnowsze instrukcje dla Niesklasyfikowane

Stihl

Stihl HT 70 Instrukcja

15 Października 2024
Ernesto

Ernesto H14270 Instrukcja

15 Października 2024
Uniden

Uniden BT MIC KIT Instrukcja

15 Października 2024
Vaude

Vaude Omnis Bike 26 Instrukcja

15 Października 2024
ART

ART ProChannel II Instrukcja

15 Października 2024
Aukey

Aukey DR02J Instrukcja

15 Października 2024
Master Lock

Master Lock 653EURD Instrukcja

15 Października 2024
Roland

Roland FR-18 Diatonic Instrukcja

15 Października 2024