Introduction
The LiftMaster® Retro-Refl ective Photoelectric
Sensor provides non-contact monitored entrapment
protection. For use with LiftMaster® UL Listed
gate operators. The sensor is a UL Recognized
Component and meets UL 325 requirements.
Monitored external entrapment protection devices
MUST be installed at each Entrapment Zone. Refer to
gate operator manual for compatibility with LMRRUL
sensor.
Speci cations
Max Range: 50 ft. (15.2 m)
Sensor Dimensions with Hood:
2.29" W x 3.72" H x 2.76" D
Refl ector Dimensions with Hood:
2.61" W x 4.72" H x 2" D
Cable Length: 10 ft. (3 m)
Operating Temperature: -40˚C to 65˚C
(-40˚F a 149˚F)
Outdoor Rating: Nema 4X
Input voltage:
Sensor: Black/red wires 6.8 VDC, 20mA
Heater: Green/white wires 10-40VDC or 8-28 VAC, 2
watts max., 170mA @ 12 VDC/VAC,
85mA@ 24 VDC/VAC
Heater: Thermostatically controlled, NOT
recommended for solar applications
MONITORED RETRO-REFLECTIVE
PHOTOELECTRIC SENSOR
Model LMRRUL
To prevent possible SERIOUS INJURY or DEATH from a closing gate or door:
Read and follow ALL instructions.
Be sure to DISCONNECT ALL POWER to the operator BEFORE installing the photoelectric sensor.
The gate or door MUST be in the fully opened or closed position BEFORE installing the LiftMaster®
Monitored Entrapment Protection device.
Correctly connect and align the photoelectric sensor.
Install the photoelectric sensor so that the center of the sensor window is NO HIGHER than
4-1/2" (11.4cm) above the oor for door operators and 26" (66 cm) above grade for gate operators.
Monitored external entrapment protection devices MUST be installed per the operator installation
manual at each Entrapment Zone.
The sensor and refl ector MUST be mounted vertically.
Use the provided refl ector ONLY.
Test the gate operator and ALL photoelectric sensors monthly. Replace ANY damaged devices.
SAVE THESE INSTRUCTIONS.
WARNING: This product can expose you to chemicals including lead, which are known
to the State of California to cause cancer or birth defects or other reproductive harm.
For more information go to www.P65Warnings.ca.gov.
Installation
IMPORTANT: The sensor and the re ector MUST be mounted vertically. Disconnect ALL power to the
operator.
1. Attach the mounting bracket to the post with 1/4"-20 screws. Drill a hole in the post through the center
hole in the bracket. Optional: If installing to a square post or fl at surface, you may attach the sensor
bracket directly to the post without using the mounting bracket. Make sure the location of the sensor
follows the specifi ed measurements. If installing multiple sensors in close proximity, mount the sensors on
opposite sides to avoid crosstalk.
2. Slide the bottom sensor bracket onto the studs of the mounting bracket and secure with 1/4"-20 lock nuts.
Make sure the bracket legs are facing down.
3. Loosely attach the top sensor bracket with 10-32x1" thread-locking screws. Make sure the slots are
facing up.
4. Place the sensor in the bracket and tighten the screws just enough to allow the sensor to rotate inside the
bracket.
5. Slide the hood over the sensor until it snaps into place. Secure hood with the M3 screw. The hood MUST
be installed on the sensor.
6. Route wires through the center hole of the mounting bracket and into the post. Optional: Use conduit with
NEMA 4X compatible 1/2"-14 NPT fi tting (not provided).
7. Place the refl ector in the refl ector hood.
8. Secure the refl ector and hood to the bracket with 8-32x1" screws. Secure the bottom of the refl ector to the
hood with 8-32x1" screws.
9. Mount the re ector a minimum of 3 ft. (.9 m) and maximum of 50 ft. (15.2 m) away from the sensor.
Carton Inventory
Photoelectric sensor with hood
and bracket
Refl ector with hood and
bracket
Wire cover
Screws 8-32x1" (4)
Lock nuts 8-32 (4)
Screws 8-32x3/8" (2)
Thread-locking screws
10-32x1" (2)
Screws 1/4"-20x1-1/4" (6)
Lock nuts 1/4"-20 (2)
M3 screw (1)
Set screw 10-32x3/8" (1)
Tools Needed
Philips screwdriver
1/8" Allen wrench
7/16" socket
11/32" socket
5/32" Allen key
3/32" Allen key
1
2
3
4
5
6
7
9
8
≤ 5" (12.7 cm)
from gate or wall Optional for
square post
Door operators:
4-1/2" (11.4 cm)
Gate operators:
4" (10.2 cm)-26" (66 cm)
Door operators: 4-1/2" (11.4 cm)
Gate operators: 4" (10.2 cm)-26" (66 cm)
≤ 5" (12.7 cm)
from gate or wall
Illustrations are for reference only; your application may look different.
Expansion Board
Black (-)
to COM
Red (+) to EYE
or EYE/EDGE
Control Board
Black (-)
Red (+)
See below
Sensor Wiring
Heater Wiring
See below
OR
OR
OR
For use with battery backup
Green
White
Green
White
Green
White
Green
White
Black (not provided)
OPTION 1
OPTION 2
OPTION 3
Control board
ACCESSORY
POWER ON
Max. draw 500 mA
Expansion board
aux relay
From Sensors
From Sensors
External 12V to 24V DC or AC power
supply (not provided) with adequate
current to power all sensors
AUX RELAY will switch
off during power failure
Set switch for open
or close direction
CLOSE EYES/INTERRUPT
for close direction
OR
OPEN EYES/EDGE for open
direction
Green
White
Control board
ACCESSORY POWER ON
Max. draw 500 mA
From Sensors
Wiring
Sensor wiring (red and black wires): Wire the photoelectric sensors (red [+] and black [-] wires) to the
appropriate inputs on the operator or expansion board as shown.
Heater wiring (green and white wires):
OPTION 1 - Connect to the ACCESSORY POWER ON terminal on the control board (NOT polarity specifi c).
OPTION 2 - Connect to an external 12V to 24V DC or AC power supply (not provided) with adequate current
to power all sensors.
OPTION 3 - For use with battery backup. Connect to ACCESSORY POWER ON and AUX RELAY terminals.
Set AUX RELAY switches as shown. In this confi guration, the heater will switch off during a power failure to
extend the battery life.
DO NOT overload the accessory power output on the control board or the external power supply.
NOTE: Heater feature is not recommended for ANY solar installations.


Specyfikacje produktu

Marka: LiftMaster
Kategoria: Niesklasyfikowane
Model: LMRRUL

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z LiftMaster LMRRUL, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje Niesklasyfikowane LiftMaster

Instrukcje Niesklasyfikowane

Najnowsze instrukcje dla Niesklasyfikowane

Stihl

Stihl HT 70 Instrukcja

15 Października 2024
Ernesto

Ernesto H14270 Instrukcja

15 Października 2024
Uniden

Uniden BT MIC KIT Instrukcja

15 Października 2024
Vaude

Vaude Omnis Bike 26 Instrukcja

15 Października 2024
ART

ART ProChannel II Instrukcja

15 Października 2024
Aukey

Aukey DR02J Instrukcja

15 Października 2024
Master Lock

Master Lock 653EURD Instrukcja

15 Października 2024
Roland

Roland FR-18 Diatonic Instrukcja

15 Października 2024