COMMERCIAL PROTECTOR SYSTEM®
MODELS CPS-UN4 AND CPSUN4G
To prevent possible SERIOUS INJURY or DEATH from a closing
gate or door:
Entrapment protection devices MUST be installed per the
operator owner's manual for each entrapment zone.
Be sure to DISCONNECT POWER to the operator BEFORE
installing the photoelectric sensor.
The gate or door MUST be in the fully opened or closed
position BEFORE installing the LiftMaster Monitored
Entrapment Protection device.
Correctly connect and align the photoelectric sensor.
For entrapment protection, install the photoelectric sensor
BEAM NO HIGHER than 6" (15 cm) above the fl oor for door
and 27.5" (69.8 cm) above grade for gate operators.
Photoelectric
Sensor
Photoelectric Sensor
27.5"
(69.8 cm)
max.
Facing the door from inside the garage
(installation procedures are the same for all door types).
Photoelectric
Sensor
6" (15 cm)
6" (15 cm)
Photoelectric
Sensor
Invisible Light Beam
Protection Area
Entrapment Zone
Photoelectric
Sensors
Photoelectric
Sensors
27.5"
(69.8 cm)
max.
Invisible Light Beam
Protection Area
Invisible Light Beam
Protection Area
Invisible Light Beam
Protection Area
IMPORTANT INFORMATION ABOUT THE
PHOTOELECTRIC SENSOR
Be sure power to the operator is disconnected.
When properly connected and aligned, the photoelectric sensor
will detect an obstruction in the path of its invisible light beam.
If an obstruction breaks the light beam while the door/gate is
closing, the operator will stop and typically reverse to the full open
position.
The sensors must be installed so that the emitter and receiver
sensors face each other across the entrapment zone and the beam
is no more than 6" (15 cm) above the fl oor for a commercial door
and no more than 27.5" (69.8 cm) above grade for a gate for
entrapment protection. Either can be installed on the left or right of
the entrapment zone as long as the sun never shines directly into
the receiver eye lens.
The brackets must be securely fastened to a solid surface such as
the wall framing. If installing in masonry construction, add a piece
of wood at each location to avoid drilling extra holes in masonry if
repositioning is necessary.
The invisible light beam path must be unobstructed. No part of
the gate or door (or door tracks, springs, hinges, rollers or other
hardware) may interrupt the beam while the door/gate is closing.
If it does, use a piece of wood to build out each sensor mounting
location to the minimum depth required for light beam clearance.
For commercial doors, additional photoelectric sensors may
be added at heights greater than 6" (15 cm) above the fl oor for
vehicle/property detection.
Photoelectric
Sensor
Photoelectric
Sensor
DOOR
SWING GATE
SLIDE GATE
LiftMaster
Commercial Door
Operators
Models FDC, FDCL, FDO, and LGE, Medium
Duty Logic, Logic 3, Logic 4, and Logic 5
LiftMaster Legacy
Gate Operators
Models CSL24V, CSW24V, RSL12V,
RSW12V, LA400, LA412 and LA500
LiftMaster 2016
UL 325 Gate
Operators
Models HCTDCU, LA400PKGU, LA412PKGU,
LA500PKGU, CSL24U, CSW24U, RSL12U,
RSW12U, CSW200501U, CSW200101U,
SL3000501U, SL3000101U, SL585U family,
and SL595U family
INTRODUCTION
APPLICATION
NOTE: The images throughout this manual are for reference and
your product may look different.
The Commercial Protector System is suitable for use in
applications where the photoelectric sensors will be exposed to
moisture. The CPS-UN4 and CPSUN4G are LiftMaster Monitored
Entrapment Protection (LMEP) devices and are compatible with
the following operators:
Vehicle/Property Detection
Monitored Entrapment Protection
WARNING: This product can expose you to chemicals including
lead, which are known to the State of California to cause cancer
or birth defects or other reproductive harm. For more information
go to www.P65Warnings.ca.gov
2
1. Fasten the bracket with the track bolts. NOTE: Always use
a fl at washer next to the radius slot. Putting track bolts in
slots will prevent brackets from pivoting.
2. Attach the bracket assembly to the wall with lag screws
(provided) or to the ground with concrete anchors (not
provided).
3. Insert the sensor into the brackets and fasten with the hex
mounting nut and lock washer.
1. Drill 1/4" holes in each track and securely fasten the bracket
with the track bolts. NOTE: Always use a at washer next to
the radius slot. To vertically attach to 2 x 4 wall stud it may
become necessary to rotate bracket to prevent wood from
splitting.
2. Insert the sensor into the bracket and fasten with the hex
mounting nut and lock washer.
INSTALLATION
ASSEMBLE AND MOUNT THE BRACKETS
Make sure the brackets are aligned so the photoelectric sensors will face each other across the entrapment zone. The brackets can be
mounted on the ground, door track, or wall.
Assemble to either side Flip one bracket and
assemble to either side
1/2" (1.3 cm)
Hole Spacing
2" (5.1 cm) Hole Spacing BRACKET ASSEMBLY CONFIGURATIONS
1/4"-20x5/8"
Track Bolts
1/4" Flat Washer
1/4" Lock Washer
1/4" Hex Nut
1/4" Lock Washer
1/4"-20 Hex Nut
1/4"-20x5/8" Track Bolts
Lock Washer
Hex Mounting Nut
Hex Mounting Nut
Lock Washer
1/4" Flat Washer
1/4" Lock Washer
1/4" Hex Nut
1/4" Lock Washer
1/4"-20 Hex Nut
1/4"-20x5/8" Track Bolts
1/4" Drill
Holes
Door Track
Photoelectric
Sensor
Photoelectric
Sensor
5" (12.7 cm) max. gap
Edge of Gate Panel
Invisible Light Beam
Photoelectric
Sensor
Photoelectric Sensor
Mounting
Post
Wall or Fence
27.5" (69.8 cm) maximum
6"
(15 cm)
6"
(15 cm)
DOOR
Mount sensors no more than 6" (15 cm) above the fl oor and at a
width between 7'-45' (2.1 m - 13.7 m).
Mount within 5" (12.7 cm) of the moving gate panel with a
maximum height of 27.5" (69.8 cm) above grade (21" [53.3 cm]
is recommended) and at a width between 7'-45' (2.1 m - 13.7 m).
The recommended mounting location is on the inside of the gate.
Determine the
confi guration for your
brackets. The assembly
of the brackets will
vary depending on
your installation.
GROUND OR WALL INSTALLATIONDOOR TRACK INSTALLATION (FOR DOOR ONLY)
GATE
3
Photoelectric Sensor
6" (15 cm) max. above the fl oor
Photoelectric Sensor Beam
6" (15 cm) max. above
the fl oor
Photoelectric Sensor Beam
27.5" (69.8 cm) maximum
above grade
Invisible Light Beam
Protection Area
Connect sensor wire to operator
(refer to Wiring section)
Liquid Tight
Conduit
Liquid
Tight
Junction
Box
INSTALLATION
CONDUIT CONNECTIONS
1. Disconnect power to the operator.
2. Use a liquid tight fi tting (1/2" [1.3 cm] trade size) with sealing washer to connect to sensors. The sensors are provided with 36"
(91.4 cm) long leads. LiftMaster recommends the use of a liquid tight junction box near each sensor to make the connection to the
sensor leads. Use rigid or fl exible liquid tight conduit (depending on local codes) from junction boxes to operator. IMPORTANT: Use a
minimum size 20 ga. copper wire for connection between the sensors and the operator.
Liquid Tight Conduit
Liquid Tight
Junction Box
Liquid Tight
Junction Box
DOOR
GATE
Connect sensor wire to operator
(refer to Wiring section)


Specyfikacje produktu

Marka: LiftMaster
Kategoria: Niesklasyfikowane
Model: CPS-UN4

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z LiftMaster CPS-UN4, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje Niesklasyfikowane LiftMaster

Instrukcje Niesklasyfikowane

Najnowsze instrukcje dla Niesklasyfikowane

Stihl

Stihl HT 70 Instrukcja

15 Października 2024
Ernesto

Ernesto H14270 Instrukcja

15 Października 2024
Uniden

Uniden BT MIC KIT Instrukcja

15 Października 2024
Vaude

Vaude Omnis Bike 26 Instrukcja

15 Października 2024
ART

ART ProChannel II Instrukcja

15 Października 2024
Aukey

Aukey DR02J Instrukcja

15 Października 2024
Master Lock

Master Lock 653EURD Instrukcja

15 Października 2024
Roland

Roland FR-18 Diatonic Instrukcja

15 Października 2024