INSTALLATION INSTRUCTIONS FOR
CP-4 AUTOMATIC GATE OPENER*
1. SERIAL NUMBER
There is a barcode serial number on the boom
of “puck” and on the product box. When calling
to talk about your product, please have this
number handy.
PRODUCT
CODE
YEAR
MADE
SERIAL
NUMBER
2. TRENCH PIPE & CABLE
NOTE:
Warranty
void if
cable not
run in
conduit
3. CONDUIT & SLIP JOINT
Aer pulling cable through plasc conduit,
insert conduit inside slip joint on “puck.
DO NOT GLUE (to un-install later, if needed).
NOTE: IN MOST CASES DO NOT
ADJUST SENSITIVITY OR REMOVE LID.
5. TEST SENSITIVITY
4. CONNECT TO GATE
RED
BLACK
POWER +
WHITE COMMON
YELLOW EXIT N.C.
BLUE EXIT N.O.
POWER
DUAL EXIT TERMINAL SINGLE EXIT TERMINAL
RED POWER +
BLACK
WHITE
BLUE FREE EXIT
or OPEN
TERMINAL
GND or COM
CP-4 works with all gate operators powered or
solar, single or dual free exit terminals.
VOLTAGE CURRENT
8-24 VAC
8-30 VDC
Standby: 30-70 µA
Alarm: 40-60 mA
SENSITIVITY ADJUSTMENT
HIGH (Default)
Detects vehicle going
5 MPH 12-14’ away
1 & 2 in OFF position
MEDIUM
Detects vehicle going
5 MPH 6-8’ away
1 ON & 2 OFF position
LOW
Detects vehicle going
5 MPH 2-3’ away
1 & 2 in ON position
1 2
ON
1 2
ON
1 2
ON
6. BURY CONDUIT & “PUCK”
Test unit with gate by swinging steel over
puck (or driving vehicle by). If it opens the gate
correctly, nish installaon by burying conduit
and puck 3-5" below surface.
80' - 100'
12' Note: Dip switch
color may vary
Trench 1/2" PVC pipe
to placement of CP-4
Smooth out enre
length of cable before
pulling thru PVC pipe
Gently pull cable thru
PVC pipe (may need
wire lubricant)
*Patent Pending
Technical Specifications
Power Required 8–24 VAC or 8–30 VDC
Stand-By Current 30–70 Microamps (μA)
Alarm Current 30–40 Milliamps (mA)
Relay Time 2–3 seconds
Relay Contacts SPDT, floating, N.O. or
N.C. (Form C)
Relay Contact Rating 1 amp/24 VDC
(1 mA at 5 VDC min. load)
Enclosure Rating IP67
Strength Rating 9.53 ton-force
8646 kgf
Temperature Range -25° F. – +140° F.
-32° C. – 60° C.
Dimensions 4.5 in. dia. x 2.5 in. high
Weight 5 lbs. with 100 ft. cable
The CP-4 complies with part 15 of the FCC
Rules. Operaon is subject to the following two
condions: (1) This device may not cause harmful
interference, and (2) this device must accept any interference
received, including interference that may cause undesired
operaon.
OTHER INSTRUCTIONS
CP-4 may be installed above ground by
screwing “puck” directly to an immovable
post or building
If installed above ground, use conduit to
mechanically protect cable (animals will eat)
Car should be going at least 5 MPH at sensor
to be detected
Install CP-4 at least:
6-10 feet away from buried power,
telephone, or invisible dog fence
10 feet away from natural gas lines
20 feet away from power pole with a
transformer
100 feet back from railroad trac
200 feet away from high power substaon
power lines
80-100 feet back from gate operator
RETURNING MERCHANDISE
CONSUMER: Contact your installer
INSTALLER: CALL BEFORE DIGGING UP
Call (717) 532-0033, opon 1 to troubleshoot
and receive a Return Merchandise Authorizaon
(R.M.A.) number. Write R.M.A. number on return
shipping box and any correspondence included
with defecve product.
DISTRIBUTOR: Send installers directly to Cartell,
using 717-532-0033, opon 1 as phone number.
5 YEAR WARRANTY
All Cartell products are warranted
against defects in material and
workmanship for ve years.
This warranty does not
cover defects caused by, but
not limited to: acts of God,
improper installaon, abuse,
re damage, electrical surges,
integrated system failures, improper lid/gasket
installaon, and damage to cable (if applicable)
caused by slicing, pulling, tangling, improper
splicing or not running in non-metalic conduit.
W
A
R
R
A
N
T
Y
W
A
R
R
A
N
T
Y
W
A
R
R
A
N
T
Y
Y
E
A
R
CONTACT INFORMATION
TECH SUPPORT 717-532-0033, opon 1
RMAs 717-532-0033, opon 1
SHIPPING 717-532-0033, opon 2
ACCOUNTING 717-532-0033, opon 3
INSIDE SALES 717-532-0033, opon 4
EMAIL info@cartell.com
ORDERING
(Distributors only) orders@cartell.com
ADDRESS 510 West King Street
Shippensburg, PA 17257
WEBSITE www.cartell.com
Copyright © 2020 by Cartell


Specyfikacje produktu

Marka: LiftMaster
Kategoria: Niesklasyfikowane
Model: 50-CP4

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z LiftMaster 50-CP4, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje Niesklasyfikowane LiftMaster

Instrukcje Niesklasyfikowane

Najnowsze instrukcje dla Niesklasyfikowane

Stihl

Stihl HT 70 Instrukcja

15 Października 2024
Ernesto

Ernesto H14270 Instrukcja

15 Października 2024
Uniden

Uniden BT MIC KIT Instrukcja

15 Października 2024
Vaude

Vaude Omnis Bike 26 Instrukcja

15 Października 2024
ART

ART ProChannel II Instrukcja

15 Października 2024
Aukey

Aukey DR02J Instrukcja

15 Października 2024
Master Lock

Master Lock 653EURD Instrukcja

15 Października 2024
Roland

Roland FR-18 Diatonic Instrukcja

15 Października 2024