P/NO :
5400252703 Rev.b
www.lge.com
INSTALLATION MANUAL
AIR CONDITIONER
Please read this installation manual completely before installing the product.
Installation work must be performed in accordance with the national wiring
standards by authorized personnel only.
Please retain this installation manual for future reference after reading it
thoroughly.
TYPE : WALL MOUNTED
ENGLISH
2Air Conditioner
Air Conditioner Installation Manual
TABLE OF CONTENTS
Safety Precautions............................3
Introduction........................................6
Symbols used in this manual..........6
Features ...........................................6
Installation..........................................7
Installation parts...............................7
Installation tools...............................7
Installation map................................8
Selecting the best location .............9
Piping length and elevation...........10
Fixing installation plate..................11
Drilling a hole in the wall...............11
Flaring work ...................................12
Connecting the piping ..................13
Connecting the cables ..................19
Checking the drainage..................21
Forming the piping.........................22
Air purging......................................23
Test running ...................................25
Installation guide at the seaside
....27
Selecting the location
(Outdoor Unit)................................27
Four type "A" screws & plastic
anchors
Connecting cable
Installation guide map
Pipes: Gas side
Liquid side
Insulation materials
Additional drain pipe
(Outer diameter ..............15.5mm)
Two type "B" screws
Level gauge
Screw driver
Electric drill
Hole core drill(ø70mm)
Horizontal meter
Flaring tool set
Specified torque wrenches
1.8kg.m, 4.2kg.m, 5.5kg.m,
6.6kg.m
(different depending on model No.)
Spanner ........................Half union
A glass of water
Screw driver
Hexagonal wrench(4mm)
Gas-leak detector
Vacuum pump
Gauge manifold
Owner's manual
Thermometer
Remote control holder
Installation
Requirements Required Parts Required Tools
Installation Manual 3
Safety Precautions
To prevent the injury of the user or other people and property damage, the following instructions
must be followed.
Be sure to read before installing the air conditioner.
Be sure to observe the cautions specified here as they include important items related to safety.
Incorrect operation due to ignoring instruction will cause harm or damage. The seriousness is
classified by the following indications.
The meanings of the symbols used in this manual are as shown below.
This symbol indicates the possibility of death or serious injury.
This symbol indicates the possibility of injury or damage to properties only.
Installation
Be sure not to do.
Be sure to follow the instruction.
Safety Precautions
ENGLISH
Always perform grounding.
• Otherwise, it may cause
electrical shock.
Donʼt use a power cord, a
plug or a loose socket
which is damaged.
• Otherwise, it may cause a fire
or electrical shock.
For installation of the product,
always contact the service
center or a professional
installation agency.
• Otherwise, it may cause a fire,
electrical shock, explosion or
injury.
Securely attach the
electrical part cover to the
indoor unit and the service
panel to the outdoor unit.
• If the electrical part cover of
the indoor unit and the service
panel of the outdoor unit are
not attached securely, it could
result in a fire or electric
shock due to dust, water, etc.
Always install an air leakage
breaker and a dedicated
switching board.
• No installation may cause a
fire and electrical shock.
Do not keep or use
flammable gases or
combustibles near the air
conditioner.
• Otherwise, it may cause a fire
or the failure of product.
Ensure that an installation frame of the
outdoor unit is not damaged due to use for
a long time.
• It may cause injury or an accident.
Do not disassemble or repair the product
randomly.
• It will cause a fire or electrical shock.


Specyfikacje produktu

Marka: LG
Kategoria: klimatyzacja
Model: S09AE

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z LG S09AE, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje klimatyzacja LG

LG

LG HS-H076QPA0 Instrukcja

15 Października 2024
LG

LG LP0824IVSM Instrukcja

9 Października 2024
LG

LG LSN363HLV Instrukcja

9 Października 2024
LG

LG LSN363HLV3 Instrukcja

9 Października 2024
LG

LG T12AWN Instrukcja

8 Października 2024
LG

LG P12AWN-14 Instrukcja

8 Października 2024
LG

LG P24AWN-14 Instrukcja

8 Października 2024
LG

LG P18AWN-14 Instrukcja

8 Października 2024
LG

LG R09AWN-13 Instrukcja

8 Października 2024
LG

LG P28AWN-14 Instrukcja

8 Października 2024

Instrukcje klimatyzacja

Najnowsze instrukcje dla klimatyzacja

Klarstein

Klarstein Vita Pure 2G Instrukcja

15 Października 2024
Gree

Gree ETAC-15HP265V20B Instrukcja

15 Października 2024
Qlima

Qlima P 126 Instrukcja

14 Października 2024
Mitsubishi

Mitsubishi MSZ-CB22VA Instrukcja

14 Października 2024
Suntec

Suntec Motion 90+ Instrukcja

14 Października 2024
Danby

Danby DTAC120B1WDB Instrukcja

14 Października 2024
Amana

Amana PTC093K35AXXX Instrukcja

14 Października 2024
Amana

Amana AMAP121AB-2 Instrukcja

14 Października 2024
Amana

Amana PTC173J35AXXX Instrukcja

14 Października 2024