VM-4DKT Quick Start
P/N:
2900- 301544QS
Rev:
1
Scan for full manual
Step 1: Check in the b what’s ox
VM-4DKT 1:4 4K HDMI/DGKAT Distribution Amplier Transmitter
4 Rubber feet
1 Quick start guide
1 Power cord and adapter
IMPORTANT NOTICE!
We highly recommend using only Kramer UNIKAT cables with these products. If using 3
rd party shielded CAT-6A cables, both ends of the
shield must be soldered to the connectors for the products to function properly. Do not use any jumpers, unshielded wall plates or mid-
span cable connections. These extenders are not compatible with HDBaseT technologies. Prior to signal extension, ensure that the
extension line cable is lying straight and not coiled.
Step 2: Get to know your -4DKT VM
#
Feature
Function
1
STATUS LED
Red Power . up
Green Power is on.
2
ACTIVE EDID LED
The LED color indicates the active EDID type. When ashing, the state is in the
process of being activated.
Yellow Default EDID.
Blue Output-acquired EDID.
Green Custom EDID.
3
INPUT LED
On Input signal detected.
Flashing Source connected, but no signal detected.
4
HDMI IN Connector
Connect to an HDMI source.
5
LOOP Connector
Connect to a local HDMI display.
6
DGKAT2 OUTPUTS Connectors (x4)
Connect to a DGKat-2.0 receiver (for example, ) using twisted pair cable. PT-872xr
7
SERVICE 3-pin terminal block
Connect to a serial controller.
8
SETUP DIP-switches
Sets the device behavior (see Step 6: Operate -4DKTVM ).
9
Fan Vent
For heat ventilation.
10
12V DC Power Connector
Connect the V DC power adapter into the device and then connect it to the 12
mains.
Step 3: Mount -4DKT VM
Install -4DKT using one of the following methods: VM
Attach the rubber feet and place the unit on a at
surface.
Ensure that the environment (e.g., maximum ambient temperature & air ow) is
compatible for the device.
Avoid uneven mechanical loading.
Appropriate consideration of equipment nameplate ratings should be used for avoiding
overloading of the circuits.
Reliable earthing of rack-mounted equipment should be maintained.
Maximum mounting height for the device is 2 meters.
Step 4: Connect inputs and outputs
Always switch OFF the power on each device before connecting it to your . VM-4DKT
Wiring the RJ-45 Connectors
This section denes the DGKAT pinout, using a straight pin- -pin cable to
with RJ-45 connectors.
EIA /TIA 568B
PIN
Wire Color
1
Orange / White
The ground shielding must be connected/soldered to the
connector shield.
2
Orange
3
Green / White
4
Blue
To achieve specied extension distances, use the
recommended Kramer cables available at
www.kramerav.com/product/VM-4DKT.
Using third-party cables may cause damage!
5
Blue / White
6
Green
7
Brown / White
8
Brown
Step 5: Connect power
Connect the power adapter the and then plug it into the mains electricity. to VM-4DKT
Safety Instructions (See for updated safety information)www.kramerav.com
Caution:
For products with relay terminals and GPI\O ports, please refer to the permitted rating for an external connection, located next to the terminal or in the User Manual.
There are no operator serviceable parts inside the unit.
Warning:
Use only the power cord that is supplied with the unit.
Disconnect the power and unplug the unit from the wall before installing.
Step 6: Operate -4DKT VM
Set the -4DKT DIP-switches: VM
A DIP-switch that is down is on, up is o. Changes to the DIP-switches take eect immediately.
#
Function
Status
1
Active EDID source
ON (down) Default EDID (default)
OFF (up) 1st OUT EDID
2
EDID auto-acquire
OFF (up) Auto-acquire enabled (default)
ON (down) Auto-acquire disabled
3
Input HDCP appearance
OFF (up) Active (default)
ON (down) Inactive
4
Compression setup
OFF (up) Standard (default)
ON (down) High
5
RS- operation mode 232
OFF (up) Normal operation mode (default)
ON (down) Firmware upgrade mode.
Control the devices:
Operate remotely, by RS-232 serial
commands transmitted by PC, or
other serial controller.
RS-232 Control / Protocol 3000
Baud Rate:
115,200
Parity:
None
Data Bits:
8
Command Format:
ASCII
Stop Bits:
1
Example (get device model name): #model?<cr>
Factory Default Parameters
P3K command:
#factory<cr>


Specyfikacje produktu

Marka: Kramer
Kategoria: odbiornik
Model: VM-4DKT

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z Kramer VM-4DKT, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje odbiornik Kramer

Kramer

Kramer VM-4HDCPXL Instrukcja

7 Października 2024
Kramer

Kramer VM-4DKT Instrukcja

24 Września 2024
Kramer

Kramer VM-1610 Instrukcja

21 Września 2024
Kramer

Kramer VM-2DP Instrukcja

21 Września 2024
Kramer

Kramer VS-1616A Instrukcja

21 Września 2024
Kramer

Kramer VM-3AN Instrukcja

20 Września 2024
Kramer

Kramer PT-102SN Instrukcja

19 Września 2024
Kramer

Kramer VM-10H2 Instrukcja

18 Września 2024
Kramer

Kramer 907xl Instrukcja

18 Września 2024
Kramer

Kramer VM-92 Instrukcja

18 Września 2024

Instrukcje odbiornik

Najnowsze instrukcje dla odbiornik

Denon

Denon AVR-S900W Instrukcja

15 Października 2024
Pro-Ject

Pro-Ject Amp Box DS2 Instrukcja

15 Października 2024
AKG

AKG HP12U Instrukcja

15 Października 2024
Apart

Apart SBR160 Instrukcja

14 Października 2024
American Audio

American Audio VLP 600 Instrukcja

14 Października 2024
Chord

Chord Anni Instrukcja

14 Października 2024
Sennheiser

Sennheiser EM 9046 SU Instrukcja

14 Października 2024
Yamaha

Yamaha MusicCast RX-V481 Instrukcja

13 Października 2024
JL Audio

JL Audio VX600/6i Instrukcja

12 Października 2024
Pioneer

Pioneer SX-303RDS Instrukcja

10 Października 2024